• Title/Summary/Keyword: Large generator

Search Result 632, Processing Time 0.036 seconds

Vibration Analysis of Hydraulic Turbine-Generator Rotor (수차발전기 축계의 진동해석)

  • 김용한;손병구;최병근;양보석;하현천
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.250-254
    • /
    • 1998
  • Pump-storage power plants, which pumps water from the lower reservoir to the upper reservoir using the extra electronic power at night and generates the electronic power in the daytime, are more increasing. Currently it has a tendency to be high-head large-capacity machines. So in the processing of design, we need to know the vibration characteristics of pump-turbine shaft system sufficiently. In this paper, we developed the computer programs for analyzing pump-turbine shaft system considering magnetic force of generator, hydraulic force at runner, dynamic characteristics of guide bearings and the effect of add mass of water. And the superiority of this program was verified by applying it to the real model and calculating high quality critical speed, natural mode and unbalance response.

  • PDF

An Improved Dynamic Programming Approach to Economic Power Dispatch with Generator Constraints and Transmission Losses

  • Balamurugan, R.;Subramanian, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.320-330
    • /
    • 2008
  • This paper presents an improved dynamic programming (IDP) approach to solve the economic power dispatch problem including transmission losses in power systems. A detailed mathematical derivation of recursive dynamic programming approach for the economic power dispatch problem with transmission losses is presented. The transmission losses are augmented with the objective function using price factor. The generalized expression for optimal scheduling of thermal generating units derived in this article can be implemented for the solution of the economic power dispatch problem of a large-scale system. Six-unit, fifteen-unit, and forty-unit sample systems with non-linear characteristics of the generator, such as ramp-rate limits and prohibited operating zones are considered to illustrate the effectiveness of the proposed method. The proposed method results have been compared with the results of genetic algorithm and particle swarm optimization methods reported in the literature. Test results show that the proposed IDP approach can obtain a higher quality solution with better performance.

An IPLAN-based Program for Technical Assessment of New-connected Facilities (IPLAN을 이용한 전력설비의 계통접속 기술검토 프로그램 개발)

  • Ryu, Heon-Su;Bae, Joo-Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.220-222
    • /
    • 2005
  • When a large-scale load or a new generator is connected to power systems, KPX assesses the effect of the connection on power systems to keep security and reliability standards. As the number of connection requests has been increased, KPX is spending much time for technical assessments of the requests. This paper developed an automatic assessment program to reduce analysis time and enhance simulation accuracy. The program is based on IPLAN and. can be applied to both load and generator network connection requests.

  • PDF

BCCOMICS: Baryon-Cold dark matter COsMological Initial Condition generator for Small-scale structures

  • Ahn, Kyungjin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.35.3-36
    • /
    • 2016
  • Density and velocity perturbations in scales most relevant for the first galaxy formation are strongly affected by large-scale density perturbations, velocity-divergence perturbations and the baryon-cold dark matter (CDM) streaming velocities. Even at redshifts as high as z~200, this mode-mode coupling imprints a significant impact on the small-scale perturbations, at the wavenumber k >${\sim}100Mpc^{-1}$, as was calculated in our recent work. This implies that cosmological initial conditions based on the usual linear theory is no longer valid in these scales. We present a new cosmological initial condition generator, BCCOMICS, which generates initial conditions for the cold dark matter (CDM) and baryons in scales most relevant for the first galaxy formation. BCCOMICS is based on the linear perturbation theory including the mode-mode coupling terms, and generates cosmological initial conditions for the SPH-basded code GADGET and the AMR-based code ENZO. We also present our preliminary result on the cosmic variance of the first galaxy formation, studied by using BCCOMICS.

  • PDF

Eigen-analysis of SSR in Power Systems with Modular Network Model Equations (Modular 네트워크 모델 구성에 의한 전력계통 SSR 현상의 고유치해석)

  • Nam, Hae-Kon;Kim, Yong-Gu;Shim, Kwan-Shik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1239-1246
    • /
    • 1999
  • This paper presents a new algorithm to construct the modular network model for SSR analysis by simply applying KCL to each node and KVL to all branches connected to the node sequentially. This method has advantages that the model can be derived directly from the system data for transient stability study and turbine/generator shaft model, the resulted model in the form of augmented state matrix is very sparse, and thus efficient SSR study of a large scale system becomes possible. The proposed algorithm is verified with the IEEE First and Second Benchmark models.

  • PDF

Resonance and Instability of Blade-Shaft Coupled Bending Vibrations with In-plane Blade Vibration

  • Anegawa, Norihisa;Fujiwara, Hiroyuki;Okabe, Akira;Matsushita, Osami
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.169-180
    • /
    • 2008
  • As a major component of a power plant, a turbine generator must have sufficient reliability. Longer blades have lower natural frequency, thereby requiring that the design of the shaft and blade takes into account the coupling of the blade vibration mode, nodal diameter k=0 and k=1 with vibration of the shaft. The present work analyzes the coupling of the translation motion of the shaft with in-plane vibration of the blades with k=1 modes. At a rotational speed ${\Omega}_1=|{\omega}_s-{\omega}_b|$, the resonance of the blades has a relatively large amplitude. A violent coupled resonance was observed at a rotational speed ${\Omega}_2=|{\omega}_s+{\omega}_b|$. Resonance in blade vibration at ${\Omega}_1=|{\omega}_s-{\omega}_b|$ was experimentally confirmed.

Slewing maneuver control of flexible space structure using adaptive CGT

  • Shimada, Yuzo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.47-50
    • /
    • 1995
  • This paper concerns an adaptive control scheme which is an extension of the simplified adaptive control. Originally, the SAC approach was developed based on the command generator tracker (CGT) theory for perfect model tracking. An attractive point of the SAC is that a control input can be synthesized without any prior knowledge about plant structure. However, a feedforward dynamic compensator of the CGT is removed from the basic structure of the SAC. This deletion of the compensator makes perfect model tracking difficult against even a step input. In this paper, an adaptive control system is redesigned to achieve perfect model tracking for as long as possible by reviving the dynamic compensator of the CGT. The proposed method is applied to slewing control of a flexible space structure and compared to the SAC responses.

  • PDF

Generator Control Method for Reactive Power Smoothing to increase Wind Power Penetration (풍력 수용 한계량 향상을 위한 발전기 무효전력 평활화 제어 기법)

  • Choi, Yun-Hyuk;Lee, Hwan-Ik;Lee, Byongjun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.197-198
    • /
    • 2015
  • As the global to increase the wind power penetration in the power system, grid-integration standards have been proposed for the stable integration of the large-scale wind farm. Particularly, the low voltage ride through function has been emphasized, as it relates to the voltage and reactive power control of the wind turbine and the rest generators. This paper proposes the non-wind power generator control method in order to improve the wind power penetration. To prove the effectiveness of the proposed strategy, the simulation study is implemented in the Jeju power system. It can improve the wind power penetration by the effective control of the control generators.

  • PDF

Dynamic droop-based power smoothing of a doubly-fed induction generator (시변 드룹을 이용한 이중여자풍력발전기의 출력 평활화)

  • Hwang, Min;Lee, Jinsik;Lee, Hyewon;Kang, Yong Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.177-178
    • /
    • 2015
  • This paper proposes a power smoothing scheme of a doubly-fed induction generator. The proposed scheme aims to mitigate system frequency deviation caused by the variable wind. To achieve this, a dynamic droop loop is used and its gain changes with rate of change of frequency so that it can release a large amount of kinetic energy at the initial stage of a frequency event. The performance of the proposed scheme was investigated in a model system with high wind penetration using EMTP-RV simulator. The test results indicate that the scheme can smooth the output power by absorbing or releasing the output power under a varying wind condition.

  • PDF

A numerical study on the optimum size for the orifice located on the steam generator cassette of integral reactor (일체형원자로 증기발생기 카세트 하단에 설치된 오리피스의 최적설계 연구)

  • Kang Hyung Seok;Yoon Juhyeon;Kim Hwan Yeol;Cho Bong Hyun;Lee Doo Jeong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.75-81
    • /
    • 1998
  • A new advanced integral reactor of 330 MWt capacity named SMART(System-integrated Modular Advanced ReacTor) is currently under development at KAERI(Korea Atomic Energy Research Institute). One of the major design features of the integral reactor is locating the steam generators(SG) inside reactor vessel and eliminating the possibility of LB LOCA(large Break Loss of Coolant Accident). Orifices are fitted at the low part of steam generator cassette to stabilize and balance coolant flow distribution in the MCP (Main Circulation Pump) pressure header. A sensitivity analysis is conducted to determine the optimum orifice size using computer code 'CFX'.

  • PDF