• 제목/요약/키워드: Large Capacity storage

검색결과 312건 처리시간 0.028초

BESS 기반 마이크로그리드 운영전략 (Operational Strategy for a BESS-based Microgrid)

  • 이하림;전영환
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1666-1672
    • /
    • 2015
  • Small islands are quite adequate places where microgrid system with renewable sources can replace diesel engines as operation costs of diesel engine in most small islands are very high. To get the large amount of renewable energy, the microgrid system has very large capacity of renewable sources. The system with large capacity of renewable sources can meet the case when supplied energy is greater than the load and the fluctuation of source output is very large. The battery energy storage system can be a solution to stabilize the system with large capacity of renewable sources. In this case, BESS can be utilized as a master source for the synchronous operation of all sources including diesel engine, wind turbine and PV. The diesel generators can be used as a backup in case the BESS SOC goes below a certain level. In this paper, we suggest a novel unit commitment of diesel generators and operation schedule of pump for water supply service with the information of wind forecast, PV forecast, and load forecast. The proposed methods has been implemented and tested at the test bed in Gasa-Island.

혼합정수계획법을 이용한 천연가스(LNG) 산업의 자가발전소 건설에 대한 경제성 분석 (Economics of Self-Generation by Natural Gas Industry Using the Mixed Integer Program)

  • 이정동;변상규;김태유
    • 산업공학
    • /
    • 제13권4호
    • /
    • pp.658-667
    • /
    • 2000
  • Seasonal variation of natural gas demand coupled with rigid and stable import pattern of gas represents the characteristic feature of the Korean Liquified Natural Gas(LNG) industry. This attribute has required a huge amount of investment for the construction of storage facility. Thus, to minimize the supply cost, it is legitimate to reduce storage requirement itself. In this study, we combine three alternative methods to deal with the storage requirement to minimize the supply cost. Those are (1) adding additional storage tanks, (2) inducing large firm customers, and (3) constructing gas-turbine self generation facilities. Methodologically, we employ the mixed integer program (MIP) to optimize the system. The model also consider demand and price-setting scheme in separate modules. From the results, it is shown that if alternatives are combined optimally, a number of storage tanks can be reduced substantially compared with the original capacity plan set by the industry authorities. We perform various sensitivity analyses to check the robustness of the results. The methodology presented in this study can be applied to the other physical network industry, such as hydraulics. The empirical results will shed some light on the rationalization of capacity planning of the Korean natural gas industry.

  • PDF

제주 태양열 계간 축열단지의 열적 특성에 관한 연구 (A Study on the Thermal Characteristics of Cheju Seasonal Installation)

  • 한유리;박윤철;천원기;강용혁;이상남
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.563-566
    • /
    • 2006
  • An investigation has been carried for the thermal characteristics of the seasonal storage installation in Cheju. It features the solar collector area of $340m^2$ and the storage capacity of $600m^3$. Four different types of solar collector systems are compared for their performance of collecting solar energy throughout the year. Of these, two are made of tubular shaped vacuum collectors and the others are flat plate collectors. Results indicate that each system could play an important role in exploiting solar energy depending on the temperature range in its operation. Especially, the vacuum collectors outperformed the others when the inlet temperatures of the collector loop were raised beyond $40m^2$. This became more conspicuous as the return temperatures from the storage tank rose reflecting the seasonal variation. Due to the large heat capacity of the storage tank, temperature changes were rather small compared to those in the collecting loop regardless of seasonal fluctuations.

  • PDF

CPC: A File I/O Cache Management Policy for Compute-Bound Workloads

  • Bahn, Hyokyung
    • International journal of advanced smart convergence
    • /
    • 제11권2호
    • /
    • pp.1-6
    • /
    • 2022
  • With the emergence of the new era of the 4th industrial revolution, compute-bound workloads with large memory footprint like big data processing increase dramatically. Even in such compute-bound workloads, however, we observe bulky I/Os while loading big data from storage to memory. Although file I/O cache plays a role of accelerating the performance of storage I/O, we found out that the cache hit rate in such environments is not improved even though we increase the file I/O cache capacity because of some special I/O references generated by compute-bound workloads. To cope with this situation, we propose a new file I/O cache management policy that improves the cache hit rate for compute-bound workloads significantly. Trace-driven simulations by replaying file I/O reference logs of compute-bound workloads show that the proposed cache management policy improves the cache hit rate compared to the well-acknowledged CLOCK algorithm by a large margin.

Pt/MOF-5 Hybrid Composite Encapsulated with Microporous Carbon Black to Improve Hydrogen Storage Capacity and Hydrostability

  • 여신영;곽승엽
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.45.2-45.2
    • /
    • 2011
  • Metal organic frameworks (MOF) have generated considerable interests as a potential candidate for hydrogen storage owing to their extremely high surface-to-volume ratio and low density. In this study, Pt nanoparticles of about 3 nm in size were introduced outside MOF-5 [$Zn_4O$(1,4-benzenedicarbocylate)3], which was then encapsulated with hydrophobic microporous carbon black (denoted CB@Pt/MOF-5) in order to enhance hydrogen uptake capacity without decreasing the specific surface area and hydrostability. To study the chemical composition, morphology, crystal information, and properties of the synthesized material, a variety of techniques is employed, including WXRD, XPS, ICP-AES, FE-SEM, HR-TEM, and N2 adsorption-desorption, confirming the formation of novel hybrid composite designated CB@Pt/MOF-5 with highly crystalline structure, large specific surface area and pore volume. In addition, $H_2$ storage capacity for resulting material was measured using magnetic suspension microbalance at 77 and 298 K under high-pressure condition, and the hydrostability was also tested by exposing the sample to 33% relative humidity at $23^{\circ}C$ and measuring XRD as a function of time.

  • PDF

대용량 공유 스토리지 시스템을 위한 토큰 버킷기반 성능 제어 기법 (Token-Bucket-based Performance Control Techniques for Large-Scale Shared Storage Systems)

  • 남영진;박찬익
    • 정보처리학회논문지A
    • /
    • 제12A권7호
    • /
    • pp.605-612
    • /
    • 2005
  • 스토리지 시스템의 성능과 용량이 증가됨에 따라서, 스토리지 시스템은 이제 다양한 사용자에 의해서 공유되어 사용되는 것이 일반화 되고있는 추세이다. 본 논문은 네트워크에서 널리 이용되는 토큰 버킷을 이용하여 공유 스토리지 시스템 상에서 각 사용자 원하는 스토리지 입출력성능을 확률적으로 보장하는 기법을 설계한다. 또한, 다양한 형태의 작업부하를 이용한 시뮬레이션을 통해서 제안된 알고리즘의 동작 및 성능을 검증한다.

근접장 기록 장치를 위한 트랙킹 구동기의 설계 및 실험 (The Design and Performance Test of Tracking Actuator for NFR system)

  • 김기현;이문구;권대갑
    • 한국정밀공학회지
    • /
    • 제18권8호
    • /
    • pp.174-181
    • /
    • 2001
  • Nowadays, the improvement and development of Multi-media and information & communication technology is rapidly processed. They need large data storage capacity. So that, many studies and researches in data storage have been carried out. According to them, the data storage capacity has been increased. But the limitation of storage capacity is happened for several problems. One of them is spot & pit size in optical and magnetic data storage and another is the resolution of actuators. The problems in spot & pit size are covered by new data storage methods-- for examples, AFM(Atomic Force Microscopy), MO(Magneto-optical) system, and NFR(Near-Field decoding) system etc. But the resolution limit of an actuator was not developed and doesn\`t follow up the development of spot & pit size. Because of them, we should improve a resolution of an actuator. Especially, in this paper an actuator if studied and designed for NFR (in using SIL(Solid Immersion Lens) system. It is a dual stage actuator, which consists of a Fine actuator and a Coarse actuator. and should desire 100nm accuracy. Its actuating force generation method is VCM(Voice Coil Motor). The Fine actuator is composed of 4-leaf springs and a bobbin wrapped by coil. The Coarse actuator has Coils and 3-Roller bearings. Also, The Characteristics of designed actuator for NFR system is estimated by Sine-Swept mode and LDV(Laser Doppler Vibro-meter).

  • PDF

A Disk-based Archival Storage System Using the EOS Erasure Coding Implementation for the ALICE Experiment at the CERN LHC

  • Ahn, Sang Un;Betev, Latchezar;Bonfillou, Eric;Han, Heejune;Kim, Jeongheon;Lee, Seung Hee;Panzer-Steindel, Bernd;Peters, Andreas-Joachim;Yoon, Heejun
    • Journal of Information Science Theory and Practice
    • /
    • 제10권spc호
    • /
    • pp.56-65
    • /
    • 2022
  • Korea Institute of Science and Technology Information (KISTI) is a Worldwide LHC Computing Grid (WLCG) Tier-1 center mandated to preserve raw data produced from A Large Ion Collider Experiment (ALICE) experiment using the world's largest particle accelerator, the Large Hadron Collider (LHC) at European Organization for Nuclear Research (CERN). Physical medium used widely for long-term data preservation is tape, thanks to its reliability and least price per capacity compared to other media such as optical disk, hard disk, and solid-state disk. However, decreasing numbers of manufacturers for both tape drives and cartridges, and patent disputes among them escalated risk of market. As alternative to tape-based data preservation strategy, we proposed disk-only erasure-coded archival storage system, Custodial Disk Storage (CDS), powered by Exascale Open Storage (EOS), an open-source storage management software developed by CERN. CDS system consists of 18 high density Just-Bunch-Of-Disks (JBOD) enclosures attached to 9 servers through 12 Gbps Serial Attached SCSI (SAS) Host Bus Adapter (HBA) interfaces via multiple paths for redundancy and multiplexing. For data protection, we introduced Reed-Solomon (RS) (16, 4) Erasure Coding (EC) layout, where the number of data and parity blocks are 12 and 4 respectively, which gives the annual data loss probability equivalent to 5×10-14. In this paper, we discuss CDS system design based on JBOD products, performance limitations, and data protection strategy accommodating EOS EC implementation. We present CDS operations for ALICE experiment and long-term power consumption measurement.

The hydrogen storage capacity of metal-containing polyacrylonitrile-based electrospun carbon nanofibers

  • Bai, Byong-Chol;Kim, Jong-Gu;Naik, Mehraj-Ud-Din;Im, Ji-Sun;Lee, Young-Seak
    • Carbon letters
    • /
    • 제12권3호
    • /
    • pp.171-176
    • /
    • 2011
  • Polyacrylonitrile-based carbon nanofibers (CNFs) containing Ti and Mn were prepared by electrospinning. The effect of metal content on the hydrogen storage capacity of the nanofibers was evaluated. The nanofibers containing Ti and Mn exhibited maximum hydrogen adsorption capacities of 1.6 and 1.1 wt%, respectively, at 303 K and 9 MPa. Toward the development of an improved hydrogen storage system, the optimum conditions for the production of metalized CNFs were investigated by characterizing the specific surface areas, pore volumes, sizes, and shapes of the fibers. According to the results of Brunauer-Emmett-Teller analysis, the activation of the CNFs using potassium hydroxide resulted in a large pore volume and specific surface area in the samples. This is attributable to the optimized pore structure of the metal-containing polyacrylonitrile-based electrospun CNFs, which may provide better sites for hydrogen adsorption than do current adsorbates.