• 제목/요약/키워드: Lamp load

검색결과 92건 처리시간 0.022초

독립형 태양광 조명 시스템의 설계 및 성능 평가 연구 (A study on the design and performance of a stand-alone photovoltaic lighting system)

  • 권오상;서유진;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.1-10
    • /
    • 2004
  • In view of global environmental problems and resource exhaustion, we must develop new energy resources that are abundant and provide substitutes for fossil fuels. Renewable energies, such as solar, are ideal because they are clean, inexhaustible, and available everywhere in the world. Photovoltaic(PV) system, in general, are operated as a stand-alone, grid-tied, or hybrid system. Many of the stand-alone PV systems are installed. Although the pre-installation cost of PV system is high, it poorly has been operated due to the absence of optimal management standards. Therefore a study on the performance of PV system is important for the system design and maintenance. In this paper a photovoltaic lighting system was resigned according to load consumption. Then a PV lighting system which used electrodeless lamp as a load was installed. In order to investigate the system operating characteristics we've added a monitoring system to the PV lighting system. The monitoring system using the LabVIEW program regularly checks the operation of the PV lighting system and records the system data. According to the system data, the stability and availability of the PV lighting system were evaluated.

물받이를 이용한 유수발전장치의 설계 및 구현 (Design and Implementation of Fluid Flow Generation System by using Water Captures)

  • 손영대;정현석
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.413-421
    • /
    • 2012
  • This paper proposes the design and implementation of fluid flow generation system by using polypropylene(PP) water capture, which harvests electric energy from the kinetic energy of tidal current or water flow and drives the desired load, and applies it to the discharge drain of Hadong thermal power plant. This experimental system is composed of water captures, driving wheel, gear trains, 10[kW] synchronous generator, and three phase rectifying circuit which drives lamp load for test. The proposed water capturing system which is composed of water captures, rope and driving wheel, rotates as caterpillar according to water flow. This system is very easy to manufacture and more economical than another type of tidal current turbines such as conventional propeller and helical type. Also, we estimated the available fluid flow energy that can be extracted from the cooling water in discharge drain based on drain's cross-sectional area. Therefore, this paper confirms the validity of proposed fluid flow generation system with water captures and the possibility of its application for renewable energy generation in discharge drain of thermal power plant, from the obtained performance characteristic of this energy conversion system.

웨이블렛 변환을 이용한 직렬 아크고장 신호 분석 (Analysis of Series Arc-Fault Signals Using Wavelet Transform)

  • 방선배;박종연
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.494-500
    • /
    • 2008
  • This paper presents the analyzed result of the series arc fault current by using the discrete wavelet transform. The series arcing is caused by a loose connection in series with the load circuit. The series arc current is limited to a moderate value by the resistance of the device connected to the circuit, such as an appliance or a lighting system. The amount of energy in the sparks from the series arcing is less than in the case of parallel arcing but only a few amps are enough to be a fire hazard. Therefore, it is hard to detect the distinctive difference between a normal current and a intermittent arc current. This paper, presents the variation of the ratio of peak values and RMS values of the series arc fault current, and proposes the novel series arc fault detecting method by using the discrete wavelet transform. Loads such as a CFL lamp, a vacuum cleaner, a personal computer, and a television, which has the very similar normal current with the arc current, were selected to confirm the novel method.

Current-Source Pulse Density Modulated Parallel Resonant Inverter with A Single Resonant Snubber and Its Unique Application

  • Wang Y.X.;Koudriavtsev O.;Konishi Y.;Okuno A.;Nakaoka M.;Lee H.W.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.261-265
    • /
    • 2001
  • In this paper, a current-source type parallel indudor compensated load resonant high-frequency soft switching inverter using IGBTs for driving the newly-produced silent discharge type ozone generating tube and excimer lamp for UV generation which incorporate a single switched capacitor resonant snubber between the port in DC busline side is presented, together with its pulse modulated unique output power regulation characteristics.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

태양광발전과 연료전지의 하이브리드 시스템 (Hybrid System of Solar Cell and Fuel Cell)

  • 황준원;최용성;이경섭
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.568-573
    • /
    • 2009
  • Because of environmental crisis, researchers are seeking and developing a new, clean, safe and renewable energy. Solar cell energy and fuel cell energy have inestimable development potential. The paper introduces hybrid photovoltaic-fuel cell generation systems supplying a remote power load and hybrid system of solar cell and fuel cell considering the advantages of stable and sustainable energy from the economic point of view. Fuel cell power system has been proven a viable technology to back up severe PV power fluctuations under inclement weather conditions. Fuel cell power generation, containing small land us, is able to alleviate the heavy burden for large surface requirement of PV power plants. In addition, the PV-fuel cell hybrid power system shows a very little potential for lifetime $CO_2$ emissions. In this paper shows the I-V characteristics of the solar module which are dependent on the power of the halogen lamp and the I-V characteristics of fuel cells which are connected in parallel. Also, it shows efficiency of the hybrid system.

CAN네트워크를 사용한 레미콘 온라인 생산 시스템 설계 (Design of On-line Readymixed Concrete Production System Using CAN Network)

  • 김동식;전태원;이홍희;김흥근;노의철
    • 전력전자학회논문지
    • /
    • 제8권4호
    • /
    • pp.359-365
    • /
    • 2003
  • 본 논문은 산업용 네트워크 중 가장 많이 사용되는 네트워크 중 하나인 CAN를 사용하여 레미콘 생산설비 시스템에 온라인 자동화하는 방식을 제시하였다. 레미콘 생산설비에서 수분센서, 로드셀 센서 등에 대한 CAN 네트워크 인터페이스회로를 설계하였으며, 2개의 상태만 있는 리미트 스위치 및 램프 등을 효율적으로 네트워킹시키는 방식을 제시하였다. CAN 네트워크를 통하여 전체 레미콘생산 설비를 호스트 컴퓨터로 제어하면서 동작상태를 모니터링하고, 본 논문에 제시한 방법을 실제 레미론설비에 적용하여 타당성을 확인하였다.

30kVA 초전도발전기의 설계 및 성능평가 (Design and Performance Testing of a 30dVA Superconducting Generator)

  • 손명환;백승규;권영길;장국렬;이언용;류강실;박도영;김용주;안종보
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.146-149
    • /
    • 1999
  • A 30kVA superconducting generator has been designed, developed and successfully tested recently. The design is based on 2-dimensional electromagnetic field analysis. The rotor has been wound with superconducting wire of Nb-Ti alloy. The stator has the air-gap type armature windings. Open-circuit test, short-circuit test and lamp load test have been conducted. The details of design program, design, machinebuilding, test results and conclusions are given in this paper.

  • PDF

유기형광법을 이용한 피스톤 유막두께의 이차원적 측정 (Measurement of two dimensional oil film thickness in piston by induced fluorescence method)

  • 민병순;최재권
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.166-174
    • /
    • 1998
  • The distribution of oil film thickness in piston were measured by induced fluorescence method. A Xe lamp was used as light source. Coumarine-6 was mixed with oil as the fluorescent dye. Fluorescent signal which is proportional to the oil film thickness was acquired by CCD camera and transmitted to the personal computer as video signal. In order to solve the problem of measurement system, irregular distribution and unstability of light intensity, as well as to know the relationship between the oil film thickness and output signal, three different calibration techniques were used. Motoring and firing tests were performed in a single cylinder research engine with transparent liner. By analyzing the oil film thickness converted from the photographed image, it was observed that each of three piston rings scrapes the oil both upward and downward and oil film thickness is not uniform horizontally at a given piston land. The amount of oil in each land was considerably affected by the engine load. It is thought that the blow-by gas blows the oil down to the crankcase.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev, Oleg;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.206-211
    • /
    • 2002
  • Silent gas discharge method has been widely applied fur ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low - cost power supply for such systems is an important task at present. This paper introduces high-frequency inverter type mode power supply designed fur ozone generation tube and ultraviolet generation excimer lamp and considerations on the design of the inverter and pulse density modulation control strategy applied in it.