• Title/Summary/Keyword: Lamp

Search Result 2,700, Processing Time 0.036 seconds

Development of Selecting Equipment for Damage of Street Lamp Circuit (가로등 회로 손상 선별 장치 개발)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2294-2297
    • /
    • 2011
  • The research which sees currently inspects the damage of the street lamp circuit which is used selectively the diode for developed. Street lamp diagnosis is developed will grasp the lighting presence of LED indication systems and will be able to inspect selectively. The case where the street lamp will not light, will be able to indicate with the relationship of LED putting out lights where the breakdown should have occurred in which part. Circuit produced PCB borads and the system will be able to confirm the breakdown point location of street lamp individual grade developed.

Impedance and Q-factor of frequence dependance accoding to ferrites on electrodeless fluorescent lamp (무전극 형광램프의 페라이트 종류에 따른 임피던스 및 Q-Factor의 주파수 의존성)

  • Kim, Hoe-Geun;You, Dae-Won;Park, Sung-Mook;Pack, Gwang-Hyeon;Choi, Young-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.3-7
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relativie property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined resistance kind, impedance, Q-factor's frequency characteristic by ferrite. Impedance, resistance and capacitance did not show difference in start frequency 2.65 [MHz] but there was difference quantity. We could know Q-factor's difference according to material, and Q-factor's is important part of antenna design.

  • PDF

Dependence of Round Type Electrodeless Lamp according to Ferrite Core and Cold Spot Temperature (둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Kim, Nam-Goon;Jung, Young-Il;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1078-1083
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of elecrodeless lamp are related to ferrite core and cold spot temperature.

Electrical and Discharge Charcteristics Analysis of Ceramic Metal Halide Lamp with Operating Method (구동방법에 따른 세라믹 메탈 할라이드 램프의 전기적 및 방전특성 분석)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Kim, Nam-Gon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1623_1624
    • /
    • 2009
  • The use of arc tubes made of ceramic material further enhanced some of the metal halide lamp’s properties. These properties translate into higher efficacy with better color rendering, stable color through lamp long life. Recently, due to an increase in the application of the ceramic metal-halide lamp, the study for the property etc. according to Ballast's driving scheme and the study for arc tube material, optimization of gas and so on are being proceeded to improve the property of the lamp. Especially, to control ceramic metal-halide lamp, the vigorous study and practical use with respect to Electronic Ballast, which has been improved in the disadvantages of the conventional Magnetic Ballast are made. In this paper, Electrical characteristics and gas insulation destroy time are analyzed by comparing magnetic ballast with electronic ballast.

  • PDF

A New End of Lamp Life Detection Method for Fluorescent Lamps (새로운 형광램프 수명말기 현상 검출 방법)

  • Cho, Gye-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.1-5
    • /
    • 2007
  • This paper presents the new detection method for the end of life on fluorescent lamps. At the end of lamp life, the lamp voltage and current asymmetrically increase and decrease more than normal state. If the ballast system does not have the protection function especially for T4 and T5 lamps, we may see the melting socket which is connected to the end of the lamp. To protect from this kind of abnormal status is the most important thing in the ballast system that has very old lamps.

Dependence of Xe Plasma Flat Fluorescent Lamp On the Electrode Gap and Dielectric Layer Thickness

  • Kang, Jong-Hyun;Lee, Yang-Kyu;Heo, Sung-Taek;Oh, Myung-Hoon;Lee, Dong-Gu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1519-1521
    • /
    • 2007
  • In this work, a coplanar-type plasma flat fluorescent lamp having cross type of electrode was fabricated by screen printing and sealing technique. Cross type of electrode with a dielectric layer were screen-printed on a rear glass plate, and then fired at $550^{\circ}C$. Phosphor was printed on and fired at $450^{\circ}C$. Finally, the lamp was sealed by frit glass at $450^{\circ}C$. The lamp of cross electrode type was studied depending on the electrode gap and the thickness of dielectric layer.

  • PDF

Electrical characteristics of 28W fluorescent lamp ballast using piezoelectric transformer (압전트랜스포머를 이용한 28W 형광등 안정기의 전기적 특성)

  • 황상모;이정선;류주현;홍재일;정영호;손은영;박창엽
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.198-202
    • /
    • 2001
  • In this study, contour vibration mode piezoelectric transformer with size of 27.5${\times}$27.5${\times}$2.6mm$^3$ using PNW-PMN-PZT ceramic was fabricated. And the piezoelectric transformer was adopted to fluorescent lamp ballast circuit. Electrical characteristics of the piezoelectric transformer were investigated for fluorescent lamp ballast application. The electrical properties and characteristic temperature rise were measured using oscilloscope and infrared temperature sensor. A 28W fluorescent lamp was successfully driven by the fabricated ballast circuit. After driving the lamp using ballast circuit for 24 min, the output power, efficiency and characteristic temperature rise of piezoelectric transformer showed the appropriate values of 28.85[W], 86.3[%] and 15[$^{\circ}C$], respectively.

  • PDF

Dimming Control of Microcontroller-based Automotive HID Lamp Ballast (마이크로컨트롤러를 이용한 자동차용 고압방전등 안정기의 조광제어)

  • Lee Jae-Hak;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.1
    • /
    • pp.47-52
    • /
    • 2005
  • This paper presents dimming control system for automotive 35W metal halide discharge(MHD) lamp electronic ballast. HID lamp demands a highly efficient ballast and very complex control circuitry that can control complex transient state in applying to automotive. Therefore, in this paper, a microcontroller-based digital control method for the HID lamp ballast is presented for optimal control that can adapt complex transient state, steady state and various environments. In developed dimming system, the system is designed to control the lamp output voltage step by step(continuous) using microcontroller according to CdS sensor. Therefore the designed dimming control system give good driving condition to diver and realize the power control effectively. The results of the proposed system is verified through various experiment results.

Brightness Property by Ferrite on Electroness Flurescent Lamp (무전극 형광램프용 페라이트에 따른 휘도특성)

  • Pack, Gwang-Hyeon;Lee, Jong-Chan;Choi, Young-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.607-610
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relativie propertye of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. Coill turn was changed from 13th to 13th turn to recognize brightness change of lamp by winding number. Optical equipment that used in an experiment was used to measure brightness (LS-100). When an electrodeless fluorescent ]amp was made using and T company's PE22, was it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.

  • PDF

Analysis on LGP with Multi-Side-Lamp (다변 광원 도광판에 대한 연구)

  • Park Jong-Ryul;Sah Jong-Youb
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.3 s.234
    • /
    • pp.361-368
    • /
    • 2005
  • LGP(Light-Guide Panel) of LCD backlight is one of the major componets which affect on the product quality of LCD. The LGP with multi-side lamp has been analized for pattern design with the uniform distribution of brightness. When given the uniform distribution of brightness as target, the distribution of dot pattern has been designed for superposed distributions of brightness for each lamp. Multi-side lamp has been tested for various types such as ㄴ-, ㄷ-, and ㅁ -shapes. The present study enhances the possibility of LGP with multi-side lamp by showing the pricise control of brightness distribution.