• 제목/요약/키워드: Laboratory set-up

검색결과 240건 처리시간 0.019초

A General Purpose Inverter Set-Up for Power Electronics Laboratory Experiments

  • Kayakesen, Mustafa Erman;Cadirci, Isik
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.434-443
    • /
    • 2010
  • A general purpose experimental set-up has been designed and implemented for students to carry out various experiments on inverters in the power electronics laboratories of universities, during a few hours of laboratory work. This is the first inverter setup that incorporates hardware and software control, as well as an optional user interface in a laboratory experimental set-up of a single multi-purpose inverter, thus making the system versatile and very practical for both undergraduate and graduate students. The system can be controlled either by a computer or through a liquid crystal display (LCD) and a keypad control unit, and it constitutes a low-cost alternative to relatively expensive commercial teaching sets. The computer provides a user friendly interface and easier control for laboratory environments equipped with computers. The LCD and keypad units eliminate the need for a computer, which makes this system usable in the laboratory as a standalone unit as well.

일정경사 수심단면에서 평균수위의 상승/저하 효과를 고려한 해빈류의 예측 (Prediction of Longshore Current with Set-up/down Effect on a Plane Beach)

  • 이철응;김영중;최한규
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.277-289
    • /
    • 1997
  • The numerical model for prediction of longshore current with set-up/down effect on a plane beach is developed using the longshore component of the depth-integrated momentum balance equation. To predict the longshore current, the wave height model should first be formulated because the longshore current depends on the wave height directly. Two wave model, regular wave model and random wave model, are developed based on the energy flux balance equation. Also, the numerical model estimating the set-up inside the shoreline is developed using both the on-offshore momentum equation and the moving boundary technique. The numerical models are verified by the analytical solution, and compared with laboratory data. It is found from the comparison that developed models may be predicted accurately the longshore current with set-up/down effect on a plane beach.

  • PDF

A Scalable Wireless Body Area Network for Bio-Telemetry

  • Saeed, Adnan;Faezipour, Miad;Nourani, Mehrdad;Banerjee, Subhash;Lee, Gil;Gupta, Gopal;Tamil, Lakshman
    • Journal of Information Processing Systems
    • /
    • 제5권2호
    • /
    • pp.77-86
    • /
    • 2009
  • In this paper, we propose a framework for the real-time monitoring of wireless biosensors. This is a scalable platform that requires minimum human interaction during set-up and monitoring. Its main components include a biosensor, a smart gateway to automatically set up the body area network, a mechanism for delivering data to an Internet monitoring server, and automatic data collection, profiling and feature extraction from bio-potentials. Such a system could increase the quality of life and significantly lower healthcare costs for everyone in general, and for the elderly and those with disabilities in particular.

Construction of Improved PCR Primer Set for the Detection of Human Enteric Adenovirus 41

  • Cho, Kyu-Bong
    • 대한의생명과학회지
    • /
    • 제24권3호
    • /
    • pp.230-238
    • /
    • 2018
  • Human enteric Adenovirus-41 (HuEAdV-41) causes gastroenteritis, which detected by the polymerase chain reaction (PCR) base diagnostic system for clinical, food, environmental, fish and shellfish samples. We developed improved PCR and nested PCR primer set which had high specificity, sensitivity and reduced times. In this study, we compared seventeen conditions reported in the previous study that was using the PCR based HuEAdV-41 detection system, and non-enteric Adenovirus were detected in nine conditions. The most sensitive detection condition was up to 25 copies however it took 184 minutes of PCR reaction time. In this study, the PCR primer set developed had same level of sensitivity, it reduced the time of detection for clinical, food and seafood samples to 112 minutes. Developed nested PCR primer set needed 112 minutes but detected up to approximately 1 copy. In addition, developed PCR and nested PCR primer set was validated with twenty samples of underground water at random, of which ten samples showed specific band without non-specific reaction. We expect this study will be used to diagnose HuEAdV-41 from various samples.

HIERARCHICAL SWITCHING CONTROL OF LONGITUDINAL ACCELERATION WITH LARGE UNCERTAINTIES

  • Gao, F.;Li, K.Q.
    • International Journal of Automotive Technology
    • /
    • 제8권3호
    • /
    • pp.351-359
    • /
    • 2007
  • In this study, a hierarchical switching control scheme based on robust control theory is proposed for tracking control of vehicle longitudinal acceleration in the presence of large uncertainties. A model set consisting of four multiplicative-uncertainty models is set up, and its corresponding controller set is designed by the LMI approach, which can ensures the robust performance of the closed loop system under arbitray switching. Based on the model set and the controller set, a switching index function by estimating the system gain of the uncertainties between the plant and the nominal model is designed to determine when and which controller should be switched into the closed loop. After theoretical analyses, experiments have also been carried out to validate the proposed control algorithm. The results show that the control system has good performance of robust stability and tracking ability in the presence of large uncertainties. The response time is smaller than 1.5s and the max tracking error is about $0.05\;m/S^2$ with the step input.

상호작용적인 웹기반 디지털 논리회로 가상실험실의 구현 (Implementation of An Interactive Web-based Virtual Laboratory For Digital Logic Circuits)

  • 김동식;서호준;서삼준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2622-2624
    • /
    • 2002
  • This paper presents a virtual laboratory system which can be creating efficiencies in the learning process. The proposed virtual laboratory system for digital logic circuits provides interactive learning environment under which the multimedia capabilities of world-wide web can be enhanced. The virtual laboratory system is implemented to describe the on-campus laboratory, the learners can obtain similar experimental data through it. The virtual laboratory system is composed of four important components: principle classroom simulation classroom, virtual experiment classroom and management system. The database connectivity is made by PHP and the virtual laboratory environment is set up slightly differently for each learner. Learning efficiencies as well as faculty productivity are increased in this innovative teaching and learning environment.

  • PDF

Gemoetrical verification of protein structure for single nucleotide polymorphism (SNP)

  • Uhm, Won-Suhk;Lee, Sung-Geun;Kim, Yang-Seok
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2005년도 BIOINFO 2005
    • /
    • pp.256-259
    • /
    • 2005
  • Among non-synonymous SNPs that cause amino acid change in the protein product, the selection of disease-causing SNPs has been of great interest. We present the comparison between the evolutionary (SIFT score) and structural information (binding pocket) to show that the incorporation between them provides an advantage of sorting disease-causing SNPs from normal SNPs. To set up the procedure, we apply the machine learning method to the test data set from the laboratory experiments.

  • PDF

Scaling analysis of the pressure suppression containment test facility for the small pressurized water reactor

  • Liu, Xinxing;Qi, Xiangjie;Zhang, Nan;Meng, Zhaoming;Sun, Zhongning
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.793-803
    • /
    • 2021
  • The small PWR has been paid more and more attention due to its diversity of application and flexibility in the site selection. However, the large core power density, the small containment space and the rapid accident progress characteristics make it difficult to control the containment pressure like the traditional PWR during the LOCA. The pressure suppression system has been used by the BWR since the early design, which is a suitable technique that can be applied to the small PWR. Since the configuration and operating conditions are different from the BWR, the pressure suppression system should be redesigned for the small PWR. Conducting the experiments on the scale down test facility is a good choice to reproduce the prototypical phenomena in the test facility, which is both economical and reasonable. A systematic scaling method referring to the H2TS method was proposed to determine the geometrical and thermohydraulic parameters of the pressure suppression containment response test facility for the small PWR conceptual design. The containment and the pressure suppression system related thermohydraulic phenomena were analyzed with top-down and bottom-up scaling methods. A set of the scaling criteria were obtained, through which the main parameters of the test facility can be determined.

전자연동장치를 위한 연동검사시스템의 개발 (Development of Interlocking Inspection Simulator for Electronic Interlocking System)

  • 이재호;황종규;박영수;박귀태
    • 전기학회논문지P
    • /
    • 제53권2호
    • /
    • pp.70-76
    • /
    • 2004
  • The purpose of interlocking system in railway is to prevent the route for a train being set up and its protecting signal cleared if there were already another, conflicting route set up and the protecting signal for that route cleared. Recently, conventional relays circuitry in industrial field is replaced to computer-based control systems according to the advance of computer and communication technology. Therefore, interlocking systems in railway field are rapidly changing from existing relay-based interlocking system to computer-based electronic ones that executes the vital interlocking logic to assure the safety train routes at trackside signaling equipment room using electronic circuits. So it is very important to verify the performance of developed electronic interlocking system by plentiful laboratory testing before actually application in the railway system. However the laboratory testing in the present state of railway signaling is preformed individually by manual, so very much test time and cost are required. To solve these problems, we are developed the simulator for automatic interlocking inspection in this research. This simulator is able to operate on general personal computer and has following beneficial functions : automatic test sheet generation for inspection, automatic inspection execution and et al. The experiments are executed to test the feasibility of the developed simulator the experimental results have good agreements with the anticipated ones.