• Title/Summary/Keyword: Laboratory Test

Search Result 6,903, Processing Time 0.035 seconds

A Study on the Hot Spot Temperature in 154kV Power Transformers

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Woo, Jung-Wook;Kwak, Joo-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.312-319
    • /
    • 2012
  • The life of a power transformer is dependent on the life of the cellulose paper, which influenced by the hot spot temperature. Thus, the determination of the cellulose paper's life requires identifying the hot spot temperature of the transformer. Currently, however, the power transformer uses a heat run test is used in the factory test to measure top liquid temperature rise and average winding temperature rise, which is specified in its specification. The hot spot temperature is calculated by the winding resistance detected during the heat run test. This paper measures the hot spot temperature in the single-phase, 154kV, 15/20MVA power transformer by the optical fiber sensors and compares the value with the hot spot temperature calculated by the conventional heat run test in the factory test. To measure the hot spot temperature, ten optical fiber sensors were installed on both the high and low voltage winding; and the temperature distribution during the heat run test, three thermocouples were installed. The hot spot temperature shown in the heat run test was $92.6^{\circ}C$ on the low voltage winding. However, the hot spot temperature as measured by the optical fiber sensor appeared between turn 2 and turn 3 on the upper side of the low voltage winding, recording $105.9^{\circ}C$. The hot spot temperature of the low voltage winding as measured by the optical fiber sensor was $13.3^{\circ}C$ higher than the hot spot temperature calculated by the heat run test. Therefore, the hot spot factor (H) in IEC 60076-2 appeared to be 2.0.

Feasibility Study on the Methodology of Test and Evaluation for UAV Positioning (무인항공기 위치정확도 시험평가 기법 연구)

  • Ju, Yo-han;Moon, Kyung-kwan;Kang, Bong-seok;Jeong, Jae-won;Son, Han-gi;Cho, Jeong-hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.530-536
    • /
    • 2018
  • Recently, many studies for interoperability of UAV in the NAS has been performed since the application range and demand of UAV are continuously increased. For the interoperation of UAV in the NAS, technical standards and certification system for UAV which is equivalent to the commercial aircraft are required and test and evaluation methodology must be presented by standards. In this paper, qualification test and evaluation methodology aboutfor the UAV navigation system is proposed. For the research, the mission profile and operation environment of UAV were analyzed. Thereafter the test criteria were derived and the test methodology were established. Finally, the simulation and demonstration using test-bed UAV were performed. As a result of the test, it was confirmed that the navigation system of test UAV has a position accuracy about 1.4 meters at 95% confidence level in the entire flight stage.

The Internal Quality Control for TEST 1, the Automatic Analyzer of Erythrocyte Sedimentation Rate (ESR 자동분석기를 이용한 내부정도관리방법)

  • Cho, Young Kuk;Sim, Hyun-Seol;Song, Woon Heung;Park, Quehn
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.239-244
    • /
    • 2004
  • Recently automatic equipment has been well popularized for the erythrocyte sedimentation rate, a widely used test, but no standard quality control has been established yet. Thus, we are going to report a case that established and applied a quality control method using the TEST 1 automatic analyzer. For internal quality control, we adopted the repeatability test through comparison with daily mean check, with a manual method using patients' specimens and with the results of a test on the previous day. In order to set the tolerance standard for each quality control method, we compared the results of 50 specimens that showed a wide range of ESR results and examined correlation and differences according to result. After setting the tolerance standard, we applied the standard at tertiary university hospitals for 120 days and investigated positive rates and re-examination rates. If the tolerance standard was exceeded, the cause was also identified. We selected a specimen of below 25 mm/hr (T1), one between 26-50 mm/hr (T2) and one of over 51 mm/hr (T3) at random. The correlation between the manual method and the automatic method was quite high (r=0.98), and it is found appropriate to set based on differences in result values below 25 mm/hr, the upper limit of the reference value, and based on differences in the percentage of result values above 25 mm/hr. Accordingly, we set the criteria for rejection above 10 mm/hr and above 20%. When the criteria were applied in the laboratory, 1.7% of specimens in the range of T1, 8.3% of those in the range of T2 and 7.5% of those in the range of T3 were rejected. Because all the rejected ones fell within the tolerance limit in re-examination calibration verification was not carried out. With the wide popularization of erythrocyte sedimentation rate analyzers that can carry out a lot of tests quickly using automatic methods, it is necessary to improve the reliability of test results by establishing internal quality control policies. We expect that an agreed standard quality control method may be established based on the method proposed in this study.

  • PDF

Research on Pesticides Residue in Commercial Agricultural Products in 2009 (2009년 유통 농산물 중 잔류농약 실태조사)

  • Lee, Ju-Young;Choe, Won-Jo;Lee, Hee-Jung;Shin, Yong-Woon;Do, Jung-Ah;Kim, Woo-Seong;Choi, Dong-Mi;Chae, Kab-Ryong;Kang, Chan-Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.2
    • /
    • pp.192-202
    • /
    • 2010
  • Pesticide residues were investigated in 16 commodities (rice, foxtail millet, buckwheat, kidney bean, peanut, sesame, orange, grapefruit, kiwifruit, spinach, perilla leaves, leek, garlic stem, garlic, ginger and oak mushroom) collected from 22 provinces (Seoul, Busan, Incheon, Daegu, Daejeon, Gwangju, Ulsan, Suwon, Seongnam, Goyang, Bucheon, Yongin, Cheongju, Jeonju, Jeju, Cheonan, Changwon, Pohang, Gumi, Jinju, Wonju and Yeosu) in 2009. Pesticides (172 kinds) were analyzed using multiresidue method by GC/MS/MS from 510 samples, and phenthoate in kiwifruit was violated by exceeding MRL. The intake assessment for 24 kinds of pesticide residues including the detected pesticides at multi pesticide residue monitoring (bifenthrin etc.) were carried out. The result showed that the ratio of EDI (estimated daily intake) to ADI (acceptable daily intake) was 0.000007~0.458% which means that the detected pesticide residues were in a safe range so that residual pesticides in the agricultural products in Korea.

New Public Key Encryption with Equality Test Based on non-Abelian Factorization Problems

  • Zhu, Huijun;Wang, Licheng;Qiu, Shuming;Niu, Xinxin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.2
    • /
    • pp.764-785
    • /
    • 2018
  • In this paper, we present a new public key encryption scheme with equality test (PKEwET). Compared to other PKEwET schemes, we find that its security can be improved since the proposed scheme is based on non-Abelian factorization problems. To our knowledge, it is the first scheme regarding equality test that can resist quantum algorithm attacks. We show that our scheme is one-way against chosen-ciphertext attacks in the case that the computational Diffie-Hellman problem is hard for a Type-I adversary. It is indistinguishable against chosen-ciphertext attacks in the case that the Decisional Diffie-Hellman problem is hard in the random oracle model for a Type-II adversary. To conclude the paper, we demonstrate that our scheme is more efficient.

Breakdown Characteristics of Dry Air under 362 kV GIB (362 kV GIB 내에서 건조공기의 절연파괴 특성)

  • Han, Ki-Son;Ju, Hyung-Jun;Yoon, Jin-Yul;You, Hong-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

Screening of New Bioactive Materials from Microbial Extracts of Soil Microorganism (I) Antimicrobial Activity from 200 Sampled Using Microdilution Assay

  • Jung, Sang-Oun;Kim, Joon;Chang, Il-Moo;Ryu, Jae-Chun
    • Archives of Pharmacal Research
    • /
    • v.21 no.3
    • /
    • pp.278-285
    • /
    • 1998
  • The microdilution assay recommended by NCCLS (National Committee for Clinical Laboratory Standards) is one of the standardized methods of antibiotic susceptibility test. This method has been widely used clinically to obtain MIC values of antibiotics on pathogenic microorganisms. It is more convenient, rapid and simple to test many samples than other test methods such as agar diffusion assay and broth macrodilution assay. The screening of antimicrobial agents from microbial extracts is too laborious in its process. Therefore, a number of screening methods having more simple procedure have been developed. In our laboratory, we applied microdilution assay for screening the antimicrobial agents. This assay showed dose-response results and was more sensitive than disc diffusion assay in our system. We tested 200 samples of microbial extracts originated from 100 microbial strains and selected several samples as potential candidates. In this report, we show that the microdilution assay is more convenient method in screeing of antibiotic susceptibility than those previously reported.

  • PDF

Accelerated and Outdoor Exposure Tests of Aluminum Coated Steel Sheets

  • Kim, Jongmin;Lee, Jaemin;Lim, Sangkyu;Jung, Choonho
    • Corrosion Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.199-204
    • /
    • 2011
  • Hot dip metallic coated steels like as galvanized (GI), zinc-aluminium (GL) and aluminium coated steels are mostly used where corrosion resistance is needed. There are two kinds (type 1 and type 2) of aluminium coated steel being commercially used among them. Type 1 aluminium coated steel is coated with an Al-5~11 wt%Si alloy and Type 2 aluminium coated steel consists of commercially pure aluminium. Type 1 Al coated steel is generally used in automotive components and electrical appliances while type 2 aluminium coated steel is mainly used in construction applications such as building cladding panels, air conditioning and ventilation system. In this study, Type 1 aluminium coated steels have tested by accelerated conditions (salt spray or corrosive gas) and outdoor exposure condition in order to understand their corrosion behaviour. Due to the distinct corrosion mechanism of Al which exposes to the severe chloric condition, Salt Spray Test cannot predict the ordinary atmospheric corrosion of Al based coated materials. In addition, the test results and their corrosion feature of Al coated steel sheets will be discussed comparing with other metallic coated steel sheets of GI and GL.

Design and analysis of a control system for a multi-magnet levitation system

  • Kweon, Soon-Man;Kim, Seog-Joo;Kim, Jong-Moon;Kim, Kook-Hun;Kim, Yong-Joo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1332-1336
    • /
    • 1990
  • This paper deals with some analytical and experimental aspects to control a multi-magnet suspended vehicle. Because the response of a multi-magnet vehicle shows mutually coupled interaction, an analytical description of the vehicle dynamics is necessary. For numerical computations, a linearized modelling of vehicle dynamics is dicussed and computer simulation is carried out. And for the experiment, a test vehicle suspended by four magnets has been made and investigated by local control of each magnet. Two algorithms by PID and state feedback control law are used and compared with each other. Some kinds of disturbance characteristics and coupling effects of the width change of the test vehicle are experimented.

  • PDF

Design of a Moving-magnet Electromagnetic Actuator for Fast Steering Mirror through Finite Element Simulation Method

  • Long, Yongjun;Mo, Jinqiu;Wei, Xiaohui;Wang, Chunlei;Wang, Shigang
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.300-308
    • /
    • 2014
  • This paper develops a moving-magnet electromagnetic actuator for fast steering mirror (FSM). The actuator achieves a reasonable compromise between voice coil actuator and piezoelectric actuator. The stroke of the actuator is between the strokes of a piezoelectric actuator and a voice coil actuator, and its force output is a linear function of air gap and excitation current within our FSM travel range. Additionally, the actuator is more reliable than voice coil actuator as the electrical connection in the actuator is static. Analytically modeling the actuator is difficult and time-consuming. Alternatively, numerous finite element simulations are carried out for the actuator analysis and design. According to the design results, a real prototype of the actuator is fabricated. An experimental test system is then built. Using the test system, the force output of the fabricated actuator is evaluated. The test results validate the actuator analysis and design.