• Title/Summary/Keyword: Lab-on-a-Chip

Search Result 198, Processing Time 0.03 seconds

DNA Chip Technologies

  • Hwang, Seoung-Yong;Lim, Geun-Bae
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.3
    • /
    • pp.159-163
    • /
    • 2000
  • The genome sequencing project has generated and will contitute to generate enormous amounts of sequence data. Since the first complete genome sequence of bacterium Haemophilus in fluenzae was published in 1995, the complete genome sequences of 2 eukaryotic and about 22 prokaryotic organisms have detemined. Given this everincreasing amounts of sequence information, new strategies are necessary to efficiently pursue the phase of the geome project- the elucidation of gene expression patterns and gene product function on a whole genome scale. In order to assign functional information to the genome sequence, DNA chip technology was developed to efficienfly identify the differential expression pattern of indepondent biogical samples. DNA chip provides a new tool for genome expreesion analysis that may revolutionize revolutionize many aspects of human kife including mew surg discovery and human disease diagnostics.

  • PDF

Development of Photo-sensor for Integrated Lab-On-a-Chip (집적화된 Lab-On-a Chip을 위한 광센서의 제작 및 특성 평가)

  • 김주환;신경식;김용국;김태송;김상식;주병권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.404-409
    • /
    • 2004
  • We fabricated photo-sensor for fluorescence detection in LOC. LOC is high throughput screening system. Our LOC screens biochemical reaction of protein using the immunoassay, and converts biochemical reaction into electrical signal using LIF(Laser Induced Fluorescence) detection method. Protein is labeled with rhodamine intercalating dye and finger PIN photodiode is used as photo-sensor We measured fluorescence emission of rhodamine dye and analyzed tendency of fluorescence detection, according to photo-sensor size, light intensity, and rhodamine concentration. Detection current was almost linearly proportional to two parameters, intensity and concentration, and was inversely proportional to photo-sensor size. Integrated LOC consists of optical-filter deposited photo-sensor and PDMS microchannel detected 50 (pg/${mu}ell$) rhodamine. For integrated LOC including light source, we used green LED as the light source and measured emitted fluorescence.

One-Touch Type Immunosenging Lab-on-a-chip for Portable Point-of-care System (휴대용 POC 시스템을 위한 원터치형 면역 센싱 랩온어칩)

  • Park, Sin-Wook;Kang, Tae-Ho;Lee, Jun-Hwang;Yoon, Hyun-C.;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1424-1429
    • /
    • 2007
  • This paper presents a simple and reliable one-touch type multi-immunosensing lab-on-a-chip (LOC) detecting antibodies as multi-disease markers using electrochemical method suitable for a portable point-of-care system (POCS). The multi-stacked LOC consists of a PDMS space layer for liquids loading, a PDMS valve layer with 50 im in height for the membrane, a PDMS channel layer for the fluid paths, and a glass layer for multi electrodes. For the disposable immunoassay which needs sequential flow control of sample and buffer liquids according to the designed strategies, reliable and easy-controlled on-chip operation mechanisms without any electric power are necessary. The driving forces of sequential liquids transfer are the capillary attraction force and the pneumatic pressure generated by air bladder push. These passive fluid transport mechanisms are suitable for single-use LOC module. Prior to the application of detection of the antibody as a disease marker, the model experiments were performed with anti-DNP antibody and anti-biotin antibody as target analytes. The flow test results demonstrate that we can control the fluid flow easily by using the capillary stop valve and the PDMS check valves. By the model tests, we confirmed that the proposed LOC is easily applicable to the bioanalytic immunosensors using bioelectrocatalysis.

Assay development and HTS on microfluidic Lab-on-a-chip

  • Yang, Eun-Gyeong
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2002.07a
    • /
    • pp.73-78
    • /
    • 2002
  • Microfluidic lab-on-a-chip (LOC) systems have enabled a new generation ofassay technologies in chemical and biomedical sciences. Caliper's microfluidic LOC systems contain a network of microscopic channels through which fluids and chemical are moved in order to perform experiments. The main advantages of these continuous-flow devices are integration and automation of multiple steps in complex analytical procedures to improve the reproducibility of the results, and eliminated the manual labor, time and pipetting errors involved in analyses. The present talk is devoted to give a brief introduction of microfluidic basics and to present in applying continuous-flow microchips to drug screening with model enzyme assays.

  • PDF

A Study on Fabrication of Fluidic Devices using Stereolithography Technology (Stereolithography 기술을 이용한 유체소자 제작에 관한 연구)

  • Lee Young Tae;Bae Yong Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.188-195
    • /
    • 2004
  • In this paper, we fabricated fluidic devices like micro-channel, pump, mixer and particular gas separator with the technology of stereolithouaphy using RP(rapid-prototyping). The fabricated fluidic devices are expected to be applied to develop Lab-on-a chip type liquid analyzer. Stereolithography technology seems effective for fabricating MEMS(Micro Electro Mechanical System) with complicated structure because it makes three dimensional fabrication possible but, exclusive devices are needed to be developed fur fabricating even more microscopic MEMS structure.

Effects of some factors on the thermal-dissipation characteristics of high-power LED packages

  • Ji, Peng Fei;Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Decreasing the thermal resistance is the critical issue for high-brightness light-emitting diodes. In this paper, the effects of some design factors, such as chip size (24 and 35 mil), substrate material (AlN and high-temperature co-fired ceramic), and die-attach material (Ag epoxy and PbSn solder), on the thermal-dissipation characteristics were investigated. Using the thermal transient method, the temperature sensitivity parameter, $R_{th}$ (thermal resistance), and junction temperature were estimated. The 35-mil chip showed better thermal dissipation, leading to lower thermal resistance and lower junction temperature, owing to its smaller heat source density compared with that of the 24-mil chip. By adopting an AlN substrate and a PbSn solder, which have higher thermal conductivity, the thermal resistance of the 24-mil chip can be decreased and can be made the same as that of the 35-mil chip.

A Ghost-Imaging System Based on a Microfluidic Chip

  • Wang, Kaimin;Han, Xiaoxuan;Ye, Hualong;Wang, Zhaorui;Zhang, Leihong;Hu, Jiafeng;Xu, Meiyong;Xin, Xiangjun;Zhang, Dawei
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.147-154
    • /
    • 2021
  • Microfluidic chip technology is a research focus in biology, chemistry, and medicine, for example. However, microfluidic chips are rarely applied in imaging, especially in ghost imaging. Thus in this work we propose a ghost-imaging system, in which we deploy a novel microfluidic chip modulator (MCM) constructed of double-layer zigzag micro pipelines. While in traditional situations a spatial light modulator (SLM) and supporting computers are required, we can get rid of active modulation devices and computers with this proposed scheme. The corresponding simulation analysis verifies good feasibility of the scheme, which can ensure the quality of data transmission and achieve convenient, fast ghost imaging passively.

Fabrication of PDMS Microlens Using Electrohydrodynamic Atomization (정전분사를 이용한 PDMS 마이크로렌즈의 제작)

  • Kang, Tae-Ho;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1841-1846
    • /
    • 2008
  • In this paper, we present the fabrication of microlens by electrohydrodynamic atomization(EHDA) of PDMS prepolymer. The diameter and contact angle of PDMS microlens can be altered by changing the applied voltage and substrate temperature at the experimental setup. It is considered that PDMS microlens can be integrated into the Lab-on-a-chip directly without any photolithographic process by EHDA. The property of PDMS microlens is confirmed by transmitting and measuring the Gaussian beam through microlens.

Calculation and measurement of optical coupling coefficient for bi-directional tancceiver module (양방향 송수신모듈 제작을 위한 광결합계수의 계산 및 측정)

  • Kim, J. D.;Choi, J. S.;Lee, S. H.;Cho, H. S.;Kim, J. S.;Kang, S. G.;Lee, H. T.;Hwang, N.;Joo, G. C.;Song, M. K.
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.500-506
    • /
    • 1999
  • We designed and fabricated a bidirectional optical transceiver module for low cost access network. An integrated chip forming a pin-PD on an 1.3 urn FP-LD was assembled by flip-chip bonding on a Si optical bench, a single mode fiber with an angled end facet was aligned passively with the integrated chip on V-groove of Si-optical bench. Gaussian beam theory was applied to evaluate the coupling coefficients as a function of some parameters such as alignment distance, angle of fiber end facet, vertical alignment error. The theory is also used to search the bottle-neck between transmittance and receiving coupling efficiency in the bi-directional optical system. Tn this paper, we confirmed that reduction of coupling efficiency by the vertical alignment error between laser beam and fiber core axis can be compensated by controlling the fiber facet angle. In the fabrication of sub-module, a'||'&'||' we made such that the fiber facet have a corn shape with an angled facet only core part, the reflection of transmitted laser beam from the fiber facet could be minimized below -35 dE in alignment distance of 2: 30 /J.m. In the same condition, transmitted output power of -12.1 dEm and responsivity of 0.2. AIW were obtained.

  • PDF

Microfluidic Biosensor System for HDL Cholesterol

  • Kim, Joo-Eun;Paek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.717-720
    • /
    • 2003
  • A chromogenic biosensor employing microfluidics on a chip has been developed for the determination of high-density lipoprotein (HDL) cholesterol (HDL-C) in human serum. We have investigated a plain and effective method to immobilize enzymes within the microchip without chemically modifying micro-channel or technically micro-fabricating column reactor and fluid channel network. In assessing risk factors of coronary heart disease, a micro-chip system would minimize requirements of instrument and reagent handling.

  • PDF