• Title/Summary/Keyword: LV ejection

Search Result 63, Processing Time 0.024 seconds

Automatic Left Ventricle Segmentation by Edge Classification and Region Growing on Cardiac MRI (심장 자기공명영상의 에지 분류 및 영역 확장 기법을 통한 자동 좌심실 분할 알고리즘)

  • Lee, Hae-Yeoun
    • The KIPS Transactions:PartB
    • /
    • v.15B no.6
    • /
    • pp.507-516
    • /
    • 2008
  • Cardiac disease is the leading cause of death in the world. Quantification of cardiac function is performed by manually calculating blood volume and ejection fraction in routine clinical practice, but it requires high computational costs. In this study, an automatic left ventricle (LV) segmentation algorithm using short-axis cine cardiac MRI is presented. We compensate coil sensitivity of magnitude images depending on coil location, classify edge information after extracting edges, and segment LV by applying region-growing segmentation. We design a weighting function for intensity signal and calculate a blood volume of LV considering partial voxel effects. Using cardiac cine SSFP of 38 subjects with Cornell University IRB approval, we compared our algorithm to manual contour tracing and MASS software. Without partial volume effects, we achieved segmentation accuracy of $3.3mL{\pm}5.8$ (standard deviation) and $3.2mL{\pm}4.3$ in diastolic and systolic phases, respectively. With partial volume effects, the accuracy was $19.1mL{\pm}8.8$ and $10.3mL{\pm}6.1$ in diastolic and systolic phases, respectively. Also in ejection fraction, the accuracy was $-1.3%{\pm}2.6$ and $-2.1%{\pm}2.4$ without and with partial volume effects, respectively. Results support that the proposed algorithm is exact and useful for clinical practice.

Myocardial Injury Following Aortic Valve Replacement for Severe Aortic Stenosis: Risk Factor of Postoperative Myocardial Injury and Its Impact on Long-Term Outcomes

  • Lee, Chee-Hoon;Ju, Min Ho;Kim, Joon Bum;Chung, Cheol Hyun;Jung, Sung Ho;Choo, Suk Jung;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.47 no.3
    • /
    • pp.233-239
    • /
    • 2014
  • Background: As hypertrophied myocardium predisposes the patient to decreased tolerance to ischemia and increased reperfusion injury, myocardial protection is of utmost importance in patients undergoing aortic valve replacement (AVR) for severe aortic valve stenosis (AS). Methods: Consecutive 314 patients (mean age, $62.5{\pm}10.8$ years; 143 females) with severe AS undergoing isolated AVR were included. Postoperative myocardial injury (PMI) was defined as 1) maximum postoperative creatinine kinase isoenzyme MB or troponin-I levels ${\geq}10$ times of reference, 2) postoperative low cardiac output syndrome or episodes of ventricular arrhythmia, or 3) left ventricular ejection fraction of less than 55% and decrease in left ventricle (LV) ejection fraction of more than 20% of the baseline value. Results: There were 90 patients (28.7%) who developed PMI. There were five cases of early death (1.6%), all of whom had PMI. On multivariable analysis, the use of histidine-tryptophan-ketoglutarate (HTK) solution instead of blood cardioplegia (odds ratio [OR], 3.06; 95% confidence interval [CI], 1.63 to 5.77; p=0.001), greater LV mass (OR, 1.04; 95% CI, 1.01 to 1.07; p=0.007), and increased cardiac ischemic time (OR, 1.13; 95% CI, 1.05 to 1.22; p<0.001) were independent predictors for PMI. Patients who had PMI showed significantly inferior long-term survival than those without PMI (p=0.049). Conclusion: PMI occurred in a considerable proportion of patients undergoing AVR for severe AS and was associated with poor long-term survival. HTK cardioplegia, higher LV mass, and longer cardiac ischemic duration were suggested as predictors of myocardial injury.

Pseudonormal or Restrictive Filling Pattern of Left Ventricle Predicts Poor Prognosis in Patients with Ischemic Heart Disease Presenting as Acute Heart Failure

  • Lee, Jae-Geun;Beom, Jong Wook;Choi, Joon Hyouk;Kim, Song-Yi;Kim, Ki-Seok;Joo, Seung-Jae
    • Journal of Cardiovascular Imaging
    • /
    • v.26 no.4
    • /
    • pp.217-225
    • /
    • 2018
  • BACKGROUND: In patients with acute heart failure (AHF), diastolic dysfunction, especially pseudonormal (PN) or restrictive filling pattern (RFP) of left ventricle (LV), is considered to be implicated in a poor prognosis. However, prognostic significance of diastolic dysfunction in patients with ischemic heart disease (IHD) has been rarely investigated in Korea. METHODS: We enrolled 138 patients with IHD presenting as AHF and sinus rhythm during echocardiographic study. Diastolic dysfunction of LV was graded as ${\geq}2$ (group 1) or 1 (group 2) according to usual algorithm using E/A ratio and deceleration time of mitral inflow, E'/A' ratio of tissue Doppler echocardiography and left atrial size. RESULTS: Patients in group 1 showed higher 2-year mortality rate ($36.2%{\pm}6.7%$) than those in group 2 ($13.6%{\pm}4.5%$; p = 0.008). Two-year mortality rate of patient with LV ejection fraction (LVEF) < 40% ($26.8%{\pm}6.0%$) was not different from those with LVEF 40%-49% ($28.0%{\pm}8.0%$) or ${\geq}50%$ ($13.7%{\pm}7.4%$; p = 0.442). On univariate analysis, PN or RFP of LV, higher stage of chronic kidney disease (CKD) and higher New York Heart Association (NYHA) functional class were poor prognostic factors, but LVEF or older age ${\geq}75$ years did not predict 2-year mortality. On multivariate analysis, PN or RFP of LV (hazard ratio [HR], 2.52; 95% confidence interval [CI], 1.09-5.84; p = 0.031), higher stage of CKD (HR, 1.57; 95% CI, 1.14-2.17; p = 0.006) and higher NYHA functional class (HR, 1.81; 95% CI, 1.11-2.94; p = 0.017) were still significant prognostic factors for 2-year mortality. CONCLUSIONS: PN or RFP of LV was a more useful prognostic factor for long-term mortality than LVEF in patients with IHD presenting as AHF.

A patient with stress induced cardiomyopathy that occurred after cessation of hormone replacement therapy for panhypopituitarism (범뇌하수체저하증의 호르몬 대체요법 중단 후 발생한 스트레스 심근병증)

  • Nam, Seoung Wan;Lee, Jun-Won;Sim, Jeong Han;Pack, Hyun Sung;Im, Changjo;Lim, Jung Soo;Ahn, Sung Gyun
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.125-129
    • /
    • 2016
  • Stress induced cardiomyopathy (SC) is characterized by transient left ventricular (LV) dysfunction in the absence of coronary artery disease. We report on a patient with panhypopituitarism who developed SC resulting from withdrawal of hormonal replacement therapy (HRT). A 52-year-old male visited our hospital for progressively worsening dyspnea. The patient had discontinued HRT 7 days ago, which had been administered for 18 months after transsphenoidal adenomectomy for pituitary macroadenoma. Initial electrocardiogram showed marked sinus bradycardia. Transthoracic echocardiography showed apical ballooning with an LV ejection fraction of 25%. No significant obstructive lesions were observed on coronary angiography. With a clinical diagnosis of SC associated with panhypopituitarism, HRT was restarted, including glucocorticoid and thyroxine, along with standard heart failure management. His LV function had normalized at 2-month follow-up. He remains asymptomatic and administration of beta-blocker and angiotensin converting enzyme inhibitor were discontinued He currently only requires HRT.

Left Ventricle Segmentation Algorithm through Radial Threshold Determination on Cardiac MRI (심장 자기공명영상에서 방사형 임계치 결정법을 통한 좌심실 분할 알고리즘)

  • Moon, Chang-Bae;Lee, Hae-Yeoun;Kim, Byeong-Man;Shin, Yoon-Sik
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.10
    • /
    • pp.825-835
    • /
    • 2009
  • The advance in medical technology has decreased death rates from diseases such as tubercle, pneumonia, malnutrition, and hepatitis. However, death rates from cardiac diseases are still increasing. To prevent cardiac diseases and quantify cardiac function, magnetic resonance imaging not harmful to the body is used for calculating blood volumes and ejection fraction(EF) on routine clinics. In this paper, automatic left ventricle(LV) segmentation is presented to segment LV and calculate blood volume and EF, which can replace labor intensive and time consuming manual contouring. Radial threshold determination is designed to segment LV and blood volume and EF are calculated. Especially, basal slices which were difficult to segment in previous researches are segmented automatically almost without user intervention. On short axis cardiac MRI of 36 subjects, the presented algorithm is compared with manual contouring and General Electronic MASS software. The results show that the presented algorithm performs in similar to the manual contouring and outperforms the MASS software in accuracy.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

Complete Transposition of Great Arteries Combined with VSD and Pulmonic Stenosis (S.D.D.) -One Case Report- (대혈관전위증 (S.D.D.) 치험 1례)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.207-214
    • /
    • 1979
  • This 3-year-old girl was observed frequent exertional dyspnea and cyanosis at crying since birth. She was not premature baby and delivered at full term normally. On physical examination, she was underdeveloped-body weight 13.5 kg, height 99 cm.- and cyanotic. There was severe clubbing on fingers. There was grade II/VI ejection systolic murmur on left lateral border of the sternum. The preoperative examinations [EKG, echocardiogram, cardiac catheterization and biventriculogram] showed that complicated T.G.A. combined vena cava[S.D.D.]. Preoperatively, we decided the corrective surgery of Rastelli operation using a. pulmonary valved conduit. The operation was performed under total circulatory arrest using deep profound hypothermia combining with extracorporeal circulation. On operation, the anatomy of the heart showed that, 1. The subaortic conus was seen and subaortic muscles were hypertrophied. 2. The VSD[type II], behind the subaortic conus-about 1 cm. in diameter, was visible only through LV cavity and, 3. The pulmonary valve ring was hypoplastic and pulmonary valvular stenosis was seen also. The subpulmonic area [LV outflow tract] was obstructed with hypertrophied muscle and mitral valve. 4. Left superior vena cava was drained to RA via coronary sinus. 5. LAD coronary artery was originated from right coronary artery and ran anterior to the pulmonary artery. According to above anatomy, we performed the VSD closure with Teflon patch, and Mustard operation combined with LV-to-pulmonary artery bypass graft using the valve contained [Hancock 16 mm] conduit. Postoperatively, adequate blood pressure could be maintained under the state of using inotropic agent [epinephrine]. On the second postoperative day, the patient died of cardiac arrest due to low cardiac output syndrome, acute renal failure and pulmonary edema.

  • PDF

Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports

  • Gustavo Gavazzoni Blume;Luka David Lechinewski;Isabela Pedroza Vieira;Nadine Clausell;Giovana Paludo Bertinato;Paulo Andre Bispo Machado-Junior;Pedro Goulart Berro;Lidia Ana Zytynski Moura;Teresa Tsang
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.1
    • /
    • pp.25-34
    • /
    • 2022
  • BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses.

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.