• Title/Summary/Keyword: LUTS

Search Result 85, Processing Time 0.022 seconds

A Study on the Urinary Incontinence, Lower Urinary Tract Symptoms, Lifestyle and Sexual Matters of Women in an Urban Area (도시지역 여성의 요실금, 하부요로증상과 일상 및 성생활과의 관계)

  • Yang, Seung-Ae;Park, Sun-Young;Shin, Soo Jin
    • Korean Journal of Adult Nursing
    • /
    • v.16 no.3
    • /
    • pp.398-408
    • /
    • 2004
  • Purpose: The purpose of this study was to identify the frequency of urinary incontinence and lower urinary symptoms, to identify lifestyle and sexual matters for UI of adult women in an urban area. Method: The sample consisted of 364 educated women from a women's health education program in a public health center. For data collection, the Bristol Female Lower Urinary Tract Symptoms Questionnaire developed by Jackson, et. al.(1996) and the demographic questionnaire were used. For data analysis, SAS 8.2 program was used. Result: The results were as follows: 1. the prevalence rate of UI was 73.63%. 45.88% of them were stress incontinence and 27.75% of them were urge incontinence. 2. Remarkable differences were found between the type of UI and LUTS in the case of urgency($x^2=42.0585$, P<0.001), unexplained incontinence($x^2=59.0585$, P<0.001), noctural incontinence($x^2=18.8080$, P<0.001) and catetherization($x^2=10.7207$, P= 0.004), burning sense($x^2=27.7400$, P<0.001). 3. Remarkable differences were found between the type of UI and lifestyle matters in the cases as follows fluid intake restriction($x^2=31.0532$, P=0.008), interference in physical activity($x^2=36.7481$, P=0.001), interference in relation with others($x^2=22.2729$, P=0.034). 4. Remarkable differences were found between the type of UI and sexual matters with difficulty of sexual intercourse($x^2=16.1898$, P=0.002), and urine leakage during sexual intercourse($x^2=17.9752$, P=0.001). Conclusion: Based on the results, developing and carrying out an adequate UI care and education program is needed.

  • PDF

Efficient Frame Synchronizer Architecture Using Common Autocorrelator for DVB-S2 (공통 자기 상관기를 이용한 효율적인 디지털 위성 방송 프레임 동기부 회로 구조)

  • Choi, Jin-Kyu;SunWoo, Myng-Hoon;Kim, Pan-Soo;Chang, Dae-Ig
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.4
    • /
    • pp.64-71
    • /
    • 2009
  • This paper presents an efficient frame synchronizer architecture using the common autocorrelator for Digital Video Broadcasting via Satellite, Second generation(DVB-S2). To achieve the satisfactory performance under severe channel conditions and the efficient hardware resource utilization of functional synchronization blocks which have been implemented, we propose a new efficient common autocorrelator structure. The proposed architecture can improve the performance of the frame and frequency synchronizer since each block operates jointly in parallel and significantly reduce the complexity of the frame synchronizer. Hence, The proposed architecture can ensure the decrease by about 92% multipliers and 81% adders compared with the direct implementation. Moreover, it has been thoroughly verified with an FPGA board and R&STM SFU broadcast test equipment and consists of 29,821 LUTs with XilinxTM Virtex IV LX200.

A Hardware Design of Feature Detector for Realtime Processing of SIFT(Scale Invariant Feature Transform) Algorithm in Embedded Systems (임베디드 환경에서 SIFT 알고리즘의 실시간 처리를 위한 특징점 검출기의 하드웨어 구현)

  • Park, Chan-Il;Lee, Su-Hyun;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.86-95
    • /
    • 2009
  • SIFT is an algorithm to extract vectors at pixels around keypoints, in which the pixel colors are very different from neighbors, such as vertices and edges of an object. The SIFT algorithm is being actively researched for various image processing applications including 3D image reconstructions and intelligent vision system for robots. In this paper, we implement a hardware to sift feature detection algorithm for real time processing in embedded systems. We estimate that the hardware implementation give a performance 25ms of $1,280{\times}960$ image and 5ms of $640{\times}480$ image at 100MHz. And the implemented hardware consumes 45,792 LUTs(85%) with Synplify 8.li synthesis tool.

A Design of DisplayPort AUX Channel (디스플레이포트 인터페이스의 AUX 채널 설계)

  • Cha, Seong-Bok;Yoon, Kwang-Hee;Kim, Tae-Ho;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • This paper presents an implementation of the DisplayPort AUX(Auxiliary) Channel. DisplayPort uses Main link, AUX Channel and Hot Plug Detect line to transfer the video & audio data. For isochronous transport service, source device converts to image and audio data which are to be transported through the Main Link and transports the restructured image and audio data to sink device. The AUX Channel provides link service and device service for discovering, initializing and maintaining the Main link. Hot Plug Detect line is used to confirm the connection between source device and sink device. The AUX Channel is implemented with 3315 LUTs(Look Up Table), 1466 Flip Flops and 168.782MHz max speed synthesized using Xilinx ISE 9.2i at SoC Master3.

Diagnostic Role of Serum Free-to-Total Prostate Specific Antigen (PSA) Ratio in Prostate Cancer with Serum Total Concentration of PSA below 4 ng/mL

  • Chang, Chih-Chun;Lee, Yi-Chen;Tsai, Huang-Wen;Yii, Shyi-Chun;Yen, Tzung-Hai;Chu, Fang-Yeh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5261-5264
    • /
    • 2015
  • Purpose: To examine the effectiveness of serum free-to-total prostate specific antigen ratio (%fPSA) for the detection of prostate cancer (PCa) in men with different serum total PSA (tPSA) categories. Materials and Methods: From January 2010 to December 2013, a total of 225 patients with lower urinary tract symptoms (LUTS) underwent tPSA and %fPSA measurements. Histological examination with calculation of Gleason score and whole body bone scans were performed in identified cases of PCa. Results: PCa was diagnosed in 44 (19.6%) patients and the remaining 181 patients had benign prostate disease. PCa was detected in 5 (23.8%), 13 (8.7%) and 26 (47.3%) cases with tPSA level ranges ${\leq}4ng/ml$, 4 to 10 ng/ml and >10 ng/ml, respectively. The average Gleason score was $7.2{\pm}0.2$. Some 6 (13.6%) out of 44 PCa patients had bone metastases. The sensitivity was 80% and specificity was 81.3% at the cut-off %fPSA of 15% in PCa patients with a tPSA level below 4 ng/mL. A lower %fPSA was associated with PCa patients with Gleason score ${\geq}7$ than those with Gleason score ${\leq}6$ ($11.7{\pm}0.98$ vs. $16.5{\pm}2.25%$, P=0.029). No obvious relation of %fPSA to the incidence of bone metastasis was apparent in this study. Conclusions: The clinical application of %fPSA could help to discriminate PCa from benign prostate disease in men with a tPSA concentration below 4 ng/mL.

Is the Neutrophil-Lymphocyte Ratio an Indicator of Progression in Patients with Benign Prostatic Hyperplasia?

  • Tanik, Serhat;Albayrak, Sebahattin;Zengin, Kursad;Borekci, Hasan;Bakirtas, Hasan;Imamoglu, M. Abdurrahim;Gurdal, Mesut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6375-6379
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate inflammation parameters and assess the utility of the neutrophil-lymphocyte ratio (NLR) as a simple and readily available predictor for clinical disease activity in patients with nenign prostate hyperplasia BPH. We also aimed to investigate the relationship between inflammatory parameters with ${\alpha}$-blocker therapy response, and evaluate the potential association between NLR and the progression of benign prostatic hyperplasia (BPH). Materials and Methods: We examined 320 consecutive patients (July 2013-December 2013) admitted to our outpatient clinic with symptoms of the lower urinary tract at Bozok University. The mean age was 60 (range, 51-75) years. Complete blood count (CBC), prostate-specific antigen (PSA), erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) were assessed. Correlations between PSA, CRP, ESR, prostate volume, International Prostate Symptom Score (IPPS), maximum urinary flow rate (Qmax), and NLR were assessed statistically. Patients were divided into two groups: high and low risk of progression. Results: NLR was positively correlated with IPSS (p=0.001, r=0.265), PSA (p=0.001, r=0.194), and negatively correlated with Qmax (p<0.001, r=-0.236). High-risk patients a had a higher NLR compared with low-risk patients, based on IPSS (p<0.001), PSA (p=0.013), and Qmax (p<0.001); however, there were no significant differences between the groups in terms of age (p>0.05), and prostate volume (p>0.05). Conclusions: NLR can predict BPH progression. We propose that increased inflammation is negatively associated with clinical status in BPH patients and suggest that NLR can give information along with LUTS severity which may be used as a readikly accessible marker for patient follow-up.

Utility of Digital Rectal Examination, Serum Prostate Specific Antigen, and Transrectal Ultrasound in the Detection of Prostate Cancer: A Developing Country Perspective

  • Kash, Deep Par;Lal, Murli;Hashmi, Altaf Hussain;Mubarak, Muhammed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3087-3091
    • /
    • 2014
  • Purpose: To determine the utility of digital rectal examination (DRE), serum total prostate specific antigen (tPSA) estimation, and transrectal ultrasound (TRUS) for the detection of prostate cancer (PCa) in men with lower urinary tract symptoms (LUTS). Materials and Methods: All patients with abnormal DRE, TRUS, or serum tPSA >4ng/ml, in any combination, underwent TRUS-guided needle biopsy. Eight cores of prostatic tissue were obtained from different areas of the peripheral prostate and examined histopathologically for the nature of the pathology. Results: PCa was detected in 151 (50.3%) patients, remaining 149 (49.7%) showed benign changes with or without active prostatitis. PCa was detected in 13 (56.5%), 9 (19.1%), 26 (28.3%), and 103 (74.6%) of patients with tPSA <4 ng/ml, 4-10 ng/ml, 10-20 ng/ml and >20 ng/ml respectively. Only 13 patients with PCa had abnormal DRE and TRUS with serum PSA <4 ng/ml. The detection rate was highest in patients with tPSA >20 ng/ml. The association between tPSA level and cancer detection was statistically significant (p<0.01). Among 209 patients with abnormal DRE and raised serum PSA, PCa was detected in 128 (61.2%). Conclusions: The incidence of PCa increases with increasing serum level of tPSA. The overall screening and detection rate can be further improved by using DRE, TRUS and TRUS-guided prostate needle biopsies.

Design and Implementation Systolic Array FFT Processor Based on Shared Memory (공유 메모리 기반 시스토릭 어레이 FFT 프로세서 설계 및 구현)

  • Jeong, Dongmin;Roh, yunseok;Son, Hanna;Jung, Yongchul;Jung, Yunho
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.797-802
    • /
    • 2020
  • In this paper, we presents the design and implementation results of the FFT processor, which supports 4096 points of operation with less memory by sharing several memory used in the base-4 systolic array FFT processor into one memory. Sharing memory provides the advantage of reducing the area, and also simplifies the flow of data as I/O of the data progresses in one memory. The presented FFT processor was implemented and verified on the FPGA device. The implementation resulted in 51,855 CLB LUTs, 29,712 CLB registers, 8 block RAM tiles and 450 DSPs, and confirmed that the memory area could be reduced by 65% compared to the existing base-4 systolic array structure.

Formulation and Preparation of Sustained Release Pellet for Alfuzosin HCI Using Fluid-bed coater (유동층 코팅기를 이용한 염산알푸조신의 서방형 과립 설계 및 제조)

  • Na, Jin-Sang;Yoon, Yang-No;Seo, Hui;Jeong, Sang-Young;Park, Eun-Seok;Hwan, Sung-Joo;Shin, Byung-Cheol;Kim, Sung-Hoon;Cho, Sun-Hang
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.6
    • /
    • pp.387-392
    • /
    • 2008
  • Alfuzosin, an Alphal-adrenoceptor antagonist is used for the treatment of patients with voiding and in a lesser extent storage lower urinary tract symptoms (LUTS) associated to benign prostatic hyperplasia (BPH). The objective of this study was to formulate sustained release alfuzosin HCl granules and assess their formulation variables. The $Eudragit^{(R)}$ as a polymer, sustained release membrane, and dibutyl sebacate (DBS) as a plasticizer were used. Multi-coated alfuzosin HCl delivery systems composed of sugar sphere, various excipients, $Eudragit^{(R)}$ and HPMC (hydroxy propyl methyl cellulose), Cellulose Acetate were prepared by fluid-bed coater. Membrane layer were used $Eudragit^{(R)}$ RS PO and NE 30D. And the alfuzosin HCl coated beads were coated immediate release drug layer for initial burst. Its dissolution test was carried out compared to conventional products ($XATRAL^{(R)}$ XL). The release rate of drug from coated beads was higher than that from $XATRAL^{(R)}$ XL in pH 6.8.

Design of MUSIC-based DoA Estimator for Bluetooth Applications (Bluetooth 응용을 위한 MUSIC 알고리즘 기반 DoA 추정기의 설계)

  • Kim, Jongmin;Oh, Dongjae;Park, Sanghoon;Lee, Seunghyeok;Jung, Yunho
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.339-346
    • /
    • 2020
  • In this paper, we propose an angle estimator that is designed to be applied to Bluetooth low-power application technology based on multiple signal classification (MUSIC) algorithm, and present the result of implementation in FPGA. The MUSIC algorithm is designed for H/W high-speed design because it requires a lot of calculations due to high accuracy, and the snapshot variable is designed to cope with various resolution requirements of indoor systems. As a result of the implementation with Xilinx zynq-7000, it was confirmed that 9,081 LUTs were implemented, and it was designed to operate at =the operating frequency of 100MHz.