• Title/Summary/Keyword: LOQ

Search Result 468, Processing Time 0.03 seconds

Development and Validation of an Analytical Method for Fungicide Sedaxane Determination in Agricultural Products using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 Sedaxane의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Park, Shin-Min;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.30-39
    • /
    • 2019
  • An analytical method was developed for the determination of sedaxane in agricultural products using liquid chromatograph-tandem mass spectrometry (LC-MS/MS). The samples were extracted with acetonitrile and partitioned with dichloromethane to remove the interference, and then purified by using silica SPE cartridges to clean up. The analytes were quantified and confirmed by using LC-MS/MS in positive ion mode using multiple reaction monitoring (MRM). The matrix-matched calibration curves were linear over the calibration ranges ($0.001-0.25{\mu}g/mL$) into a blank extract with $r^2$>0.99. For validation, recovery tests were carried out at three different concentration levels (LOQ, 10LOQ, and 50LOQ, n=5) with five replicates performed at each level. The recoveries were ranged between 74.5 to 100.8% with relative standard deviations (RSDs) of less than 12.1% for all analytes. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40, 2003) and Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for sedaxane determination in agricultural commodities.

Modification and Validation of an Analytical Method for Dieckol in Ecklonia Stolonifera Extract (곰피추출물의 지표성분 Dieckol의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Oh, Geon;Jin, Heegu;Oh, Hyun-Ji;Kim, Eunjin;Kim, Jongwook;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.143-148
    • /
    • 2022
  • This study was to investigate an analytical method for determining dieckol content in Ecklonia stolonifera extract. According to the guidelines of International Conference on Harmonization. Method validation was performed by measuring the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of dieckol using high-performance liquid chromatography-photodiode array. The results showed that the correlation coefficient of calibration curve (R2) for dieckol was 0.9997. The LOD and LOQ for dieckol were 0.18 and 0.56 ㎍/mL, respectively. The intra- and inter-day precision values of dieckol were approximately 1.58-4.39% and 1.37-4.64%, respectively. Moreover, intra- and inter-day accuracies of dieckol were approximately 96.91-102.33% and 98.41-105.71%, respectively. Thus, we successfully validated the analytical method for estimating dieckol content in E. stolonifera extract.

Simultaneous analysis of 12 kind maker components in Banhabaekchulchhonma-tang by RP-HPLC (RP-HPLC를 이용한 반하백출천마탕에서 12종 지표성분의 동시분석)

  • Lee, Kwang Jin;Yang, Hye Jin;Ma, Jin Yeul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4682-4691
    • /
    • 2014
  • Banhabaekchulchhonma-tang is a traditional Korean herbal prescription with a range of pharmacological activities. In this study, the simultaneous analysis of 12 kinds of marker components, Homogentisic acid, Hesperidin, Naringin, Alisol A, Atractylenolide II, Atractylenolide III, Ginsenoside Rg1, Formononetin, Gastrodin, Berberine, Palmatine and 6-gingerol, in Banhabaekchulchhonma-tang was performed using high-performance liquid chromatography (RP-HPLC). The standard sample of commercial $C_{18}$ reversed phase-column using water (0.1% TFA) and acetonitrile as the mobile phase with a step gradient elution mode. The flow rate (1.0mL/min), injection volume ($10{\mu}L$) and column oven temperature ($40^{\circ}C$) at a 200, 220, 280 and 340nm wavelength was conducted. All calibration curves of the standard components showed good linearity ($r^2$ >0.999). In addition, the limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.012 to $0.878{\mu}g/mL$ and 0.009 to $0.290{\mu}g/mL$. The precision intra-day and inter-day were ranged from 0.07 to 1.21% and 0.20 to 0.90%, respectively. The recoveries ranged from 97.17 to 108.40%. Each sample amount showed a very small change. These results highlight the efficient quality evaluation of Banhabaekchulchhonma-tang.

A Study of Interference Factor of Analysis Method of Hexavalent Chromium in Soil using UV/VIS Spectrometry and Application of Ion Chromatography (자외선/가시선 분광법을 이용한 토양 중 6가 크롬 분석방법의 방해요인 분석 및 이온크로마토그래피 적용에 관한 연구)

  • Noh, Hoe-Jung;Lee, Myung-Gyu;Lee, Hyeon Seok;Kim, Mira;Kim, Dongho;Kim, Tae Seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.33-42
    • /
    • 2012
  • This study was performed to find the problems according to interference factors (organic matter, pH, Cr, Mn, Fe, clay, and etc.) when we analyzed the hexavalent chromium [Cr(VI)] in soils using UV/VIS spectrometer (US EPA 7196A), attempted to evaluate the domestic applicability of analytical method (US EPA 7199) using IC-UV/VIS spectrometer as alternative method. The recovery rate of certified reference materials was 75.0% (US EPA 7196A) and 101.4% (US EPA 7199) by the analytical methods. As the results of performing QA/QC about US EPA 7199, method detection limit (MDL) and limit of quantification (LOQ) were 0.062 mg/kg, 0.196 mg/kg, respectively. The LOQ of US EPA 7199 was lower than that of the current soil official testing method in Korea (0.5 mg/kg). Cr(VI) contents in 23 soil samples were compared by the analytical methods of EPA 7196A and 7199. Cr(VI) was detected in 13 of 23 soil samples by EPA 7196A, while EPA 7199 was not detected in any soil samples. The Cr(VI) content in 23 soil samples by EPA 7196A was not clearly correlated with Cr, Fe, Mn and clay content in the soil samples. However, the contents of Cr(VI) and organic matter of the soil samples had the highest coefficient of determination ($R^2$) of 0.80. In order to evaluate the correlation between the recovery rates of Cr(VI) and organic matter contents in the soil samples, the recovery rates of 5 soil samples added Cr(VI) standard solution were analyzed by the analytical methods. According to the results, the higher the organic matter contents in soil samples, the lower the recovery rates of Cr(VI) by US EPA 7196, while in case of US EPA 7199, the recovery rates were stable regardless of the organic matter contents.

Simultaneous determination of illegal galactagogue adulterants in supplement diets by LC-MS/MS

  • Lee, Ji Hyun;Cho, So-Hyun;Park, Han Na;Park, Hyoung Joon;Kim, Nam Sook;Park, Sung Kwan;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.171-178
    • /
    • 2018
  • Recently, for successful lactation, many breastfeeding mothers seek various products, including herbal medicine, dietary supplements, and prescribed medicines, to improve milk production. As demand for galactogogues grows, it is highly possible that pharmaceutical galactogogues may be adulterated with illegal products to maximize their efficacy. For continuous control and supervision of illegal products, we developed and validated a simple and sensitive LC-MS/MS method capable of simultaneously determining five galactogogues. Chromatographic separation was conducted using an Agilent Poroshell $120SB-C_{18}$ column with a mobile phase consisting of 20 mM ammonium formate (pH 5.4) and 100 % acetonitrile. The total run time was 13 min per analyte. The proposed method was performed according to the guidelines of the International Conference of Harmonization and it produced reliable results. This method showed high sensitivity and specificity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 0.01-0.82 ng/mL and 0.02-2.45 ng/mL, respectively, for the solid- and liquid-type samples. Specificity was evaluated by analyzing matrix-blank samples spiked with the target compounds at LOQ levels, which provided a good separation of all peaks without interference. Additionally, the repeatability and intermediate precision were typically <15 %, whereas the recovery was 80-120 % of the values obtained using blank samples. Thus, we concluded that this method could be used for the identification and quantification of galactogogues in food or herbal products.

Comparison of Extraction Methods for Determination of Vitamin K1 in Vegetables (채소류의 비타민 K1 분석을 위한 추출방법의 비교)

  • Kim, Hyeongi;Choi, Youngmin;Cho, Young-Sook;Sung, Jeehye;Ham, Hyeonmi;Lee, Junsoo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1791-1795
    • /
    • 2014
  • The objective of this study was to compare two extraction methods for determination of vitamin K1 (phylloquinone) in vegetables. In addition, analytical method validation parameters such as accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), and linearity were calculated to ensure the method's validity. Vitamin K1 was quantified by reversed-phase HPLC using post-column derivatization and fluorescence detection ($Ex{\lambda}=243nm$, $Ex{\lambda}=430nm$). Higher analytical values were observed using solvent extraction compared to those from the enzyme extraction method. The results from the method validation showed high linearity in the calibration curve with a coefficient of correlation ($R^2$) of 0.9994. The LOD and LOQ were 0.1335 and 0.2784 ng/injection volume ($50{\mu}L$), respectively. The inter-day precision and inter-day precision were 2.0% and 2.1%, respectively. Overall recovery was close to 100% (n=5). The phylloquinone contents ranged from 9.42 to $1,212.57{\mu}g/100g$. Our study provides reliable data on the phylloquinone contents in commonly consumed vegetables in Korea.

A Study of Roasting Conditions on Benzo[a]pyrene Content in Coffee Beans (로스팅 정도에 따른 원두커피의 벤조피렌 함량 연구)

  • Kim, Sang Eun;Kim, Jong Hwan;Lee, Sang Won;Lee, Moon Jo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.1
    • /
    • pp.134-138
    • /
    • 2013
  • Benzo[a]pyrene, a polycyclic aromatic hydrocarbon (PAH) whose metabolites are mutagenic and highly carcinogenic, is listed as a Group 1 carcinogen by the IARC. In this study, Arabica and Robusta green coffee beans were roasted under controlled conditions and the formation of benzo[a]pyrene during the roasting process was monitored. The concentration of benzo[a]pyrene in ground coffee and brewed coffee were determined by a HPLC-fluorescence detector. The limit of detection (LOD) and limit of quantitation (LOQ) of benzo(a)pyrene were 0.03 and $0.09{\mu}g/kg$, respectively. Benzo[a]pyrene was only detected in the dark roast of ground coffee, with a concentration ranging from $0.147{\sim}0.757{\mu}g/kg$. The content of benzo[a]pyrene in Ethiopia Mocha Harrar G4 is the highest ($0.757{\mu}g/kg$).

Establishment of an Analytical Method for Azorubine, an Undesignated Food Colorant in Korea

  • Kim, Min-ji;Park, Ju-hee;Suh, Hee-Jae;Lee, Chan
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.311-318
    • /
    • 2016
  • Azorubine is a synthetic tar color containing azo-bond in the molecular structure. This food colorant has been allowed to be used for beverages, cheese and dried fruits in the European Union and for some food in Australia. Even though it is applicable as a food color in many countries, this compound has not been permitted in Korea so far as a food additive. Thus, this study was performed to establish an analysis method for azorubine in Korea by comparison of three HPLC analysis methods for azorubine and other azo-compounds which are officially used in the European Food Safety Authority (EFSA, EU), the Food Standard Agency (FSA, England) and the National Institute of Food and Drug Safety Evaluation (NIFDS, Korea). The analysis method of the FSA for azorubine showed the best linearity ($r^2=0.999$), limit of detection (LOD, $0.07{\mu}g/mL$), limit of quantification (LOQ, $0.20{\mu}g/mL$), precision (0~0.5%) and accuracy (98.6~100.7%) among tested HPLC methods using a C-18 column and diode array detector (DAD) with ammonium acetate solution and acetonitrile as an eluent solution. Finally selected method of FSA was further verified by inter-day and intra-day experiments with linearity, LOD, LOQ, precision and accuracy. Recovery test showed the recover ratios of 97~103%, 95~101%, and 93~102% in beverages, breads/snacks and other foods, respectively. Inter-laboratory test represented the absolute value of z-score of less than 2 which means satisfactory levels in this test. Selected method of FSA showed reliable analytical results in application test using food samples collected in commercial markets in Europe.

Variation of Saponin Content in the Decoctions of Platycodi Radix (II) (길경(桔梗)의 추출조건에 따른 사포닌함량의 변화 (제2보))

  • Yoo, Dae-Seok;Choi, Yeon-Hee;Cha, Mi-Ran;Choi, Chun-Whan;Kim, Mi-Ri;Yon, Gyu-Hwan;Hong, Kyung-Sik;Lee, Byung-Hoe;Kim, Eun-Ju;Cho, Sang-Wook;Kim, Young-Sup;Ryu, Shi-Yong;Kang, Jong-Seong
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.2
    • /
    • pp.147-152
    • /
    • 2010
  • The capability of the solvents for extracting the bioactive saponins from the roots of Platycodon grandiflorum (Campanulaceae) was investigated to obtain an ideal extract which contained bioactive saponins with high quality and high quantity. The content of eight representative saponins in extracts, such as deapioplatycoside E, platycoside E, platyconic acid A and platycodin D, platycodin $D_3$, platycodin $D_2$, polygalacin $D_2$, polygalacin D were analyzed simultaneousely by the modified HPLC analytical method. The validation test of the modified qualitative and quantitative analytical method employing the ELSD equipped HPLC for eight representative saponins in the roots extract of P. grandiflorum showed a good linearity, precision and accuracy. the correlation coefficient ($r^2$) values of the calbration curves for each saponins were observed to be over 0.9990. LOD and LOQ of each saponin was calculated as $0.10{\mu}g{\sim}0.40{\mu}g$ (LOD) and $0.40{\mu}g{\sim}0.80{\mu}g$ (LOQ), respectively. Recovery rates of each saponin were also calculated as over 98%, respectively. With exception of two saponins, platyconic acid A and platycodin D, The content of eight saponins in extracts was decreased proportionally to the increment of the water ratio of solvent for extraction. Consequently, as aquous alcohol was used as a solvent for extracting the saponin components from powdered roots of P. grandiflorum, the water content in the aquous alcohol was seemed to be a critical factor for extracting efficacy. The 60-80% ratio of alcohol in the aquous alcohol were deduced to be suitable and recommendable for the preparation of roots extract of P. grandiflorum which contained saponins with high quality and high quantity.

Development of Analytical Method for Quality Control from New Herbal Medicine(HPL-4) (새로운 생약복합제제(HPL-4)의 품질관리를 위한 분석법 개발)

  • Kim, Se-Gun;Sharma, Dipak Kumar;Lamichhane, Ramakanta;Lee, Kyung-Hee;Han, Sang-Mi;Jung, Hyun-Ju
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.4
    • /
    • pp.338-345
    • /
    • 2014
  • HPL-4 is a new herbal formulation developed for the treatment of osteoarthritis. In this study, we took HPL-4 to develop a method for simultaneous determination of nine marker compounds (protocatechuic acid, chlorogenic acid, liriodendrin, nodakenin, ${\beta}$-$\small{D}$-(3-O-sinapoyl)frucofuranosyl-${\alpha}$-$\small{D}$-(6-O-sinapoyl)glucopyranoside, quercitrin, 6-gingerol, decursin and decursinol angelate) present in the formulation. The analytes were separated by UPLC system consisting of diode array detector at 205 nm and RP-amide column, and solvent system of $ACN/0.1%H_3PO_4$. Analytical method was validated to evaluate its linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy. All standards showed good linearity ($R^2$ >0.99) in the rage of $0.25-400.0{\mu}g/mL$. The LOD and LOQ were within the range of 0.021-0.148 and $0.070-0.448{\mu}g/mL$, respectively. Intra- and inter-day precision was less than RSD 4.0% and the accuracy was range from 92.00-104.81% with RSD<4.2%. The results suggest that the developed UPLC method is precise, accurate and effective, and could be applied for quality control of HPL-4 formulation.