• Title/Summary/Keyword: LOAD CELL

Search Result 1,188, Processing Time 0.03 seconds

Conceptual Design and Demonstration of Space Scale for Measuring Mass in Microgravity Environment

  • Kim, Youn-Kyu;Lee, Joo-Hee;Choi, Gi-Hyuk;Choi, Ik-Hyeon
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.419-425
    • /
    • 2015
  • In this study, a new idea for developing a space scale for measuring mass in a microgravity environment was proposed by using the inertial force properties of an object to measure its mass. The space scale detected the momentum change of the specimen and reference masses by using a load-cell sensor as the force transducer based on Newton's laws of motion. In addition, the space scale calculated the specimen mass by comparing the inertial forces of the specimen and reference masses in the same acceleration field. By using this concept, a space scale with a capacity of 3 kg based on the law of momentum conservation was implemented and demonstrated under microgravity conditions onboard International Space Station (ISS) with an accuracy of ${\pm}1g$. By the performance analysis on the space scale, it was verified that an instrument with a compact size could be implemented and be quickly measured with a reasonable accuracy under microgravity conditions.

Implementation and estimation of the urophonography measurement system for diagnosis of Lower urinary tract symptom (하부요로계 폐색 진단용 요류음 계측 시스템의 구현 및 평가)

  • Jeong, Do-Un;Cho, Seong-Taek;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.7-15
    • /
    • 2005
  • A sensor and measuring system were implemented to measure both uroflow and urophonography signal during urination for diagnose the lower urinary tract symptom. The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluate the developed system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter which can most effectively reflected by the occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253{\sim}282$ Hz of the urophonography signal.

ZVS-PWM Boost Chopper-Fed DC-DC Converter with Load-Side Auxiliary Edge Resonant Snubber

  • Ogura K.;Chandhaket S;Nagai S;Ahmed T;Nakaoka M
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.223-226
    • /
    • 2003
  • This paper presents a high-frequency ZVS-PWM boost chopper-fed DC-DC converter with a single active auxiliary edge-resonant snubber which is used for power conditioner such as solar photovoltaic generation and fuel cell generation. The experimental results of boost chopper fed ZVS-PWM DC-DC converter are evaluated. In audition to its switching voltage and current waveforms, and the switching v-i trajectory of the power devices are discussed and compared with the conventional hard switching DC-DC converter treated here. The temperature performance of IGBT module,, efficiency, and EMI noise characteristics of this ZVS-PWM DC-DC converter using IGBTs are measured and evaluated from an experimental point of view.

  • PDF

Immunomodulatory properties of medicinal maggots Lucilia sericata in wound healing process

  • Bohova, Jana;Majtan, Juraj;Takac, Peter
    • CELLMED
    • /
    • v.2 no.3
    • /
    • pp.23.1-23.7
    • /
    • 2012
  • The healing properties of medicinal maggots (larval stage of Lucilia sericata) are widely used in the chirurgical debridement of non-healing wounds including diabetic foot ulcers, venous and pressure ulcers, where classical approaches have failed. Several kinds of wounds are prone to complications coming out of a specific wound bed environment. There are multi-resistant bacterial species present, their pathogenic impact is multiplied by their ability to form a biofilm. Moreover, immunological events in chronic wounds differ from those in acute wounds. Non-healing wounds are cycled in the early inflammation phase with increased levels of inflammation attributes like inflammation cytokines and matrix metalloproteinases produced by inflammation phase cells. Application of larval therapy promotes progress in the healing process to the next stages involving tissue granulation and re-epithelisation. Larval debridement is an effective method of cleaning the wound of cell debris, necrotic tissue and bacterial load. This happens in a mechanical and biological manner, but the whole complex mechanism of the maggot healing activity is still not fully elucidated. Centuries of clinical practice brings noticeable proof of the maggots' beneficial effect in wound healing management. This long history led to the investigation of the bioactive components of the larval body and its extracts in vitro. We introduce a review which describes the immunomodulation impact of maggot body components on the cellular and molecular levels of the wound healing process.

A Study on the Hydrogen Supply for Variation in Output from a Metal Hydride Canister (금속수소화물 금속용기로부터 출력변동에 필요한 수소공급에 관한 연구)

  • Jung, Young-Guan;Kim, Se-Woong;Kim, Kyung-Hoon;Choi, Seong-Dae;Jang, Tae-Ik;Hwang, Chul-Min
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.3
    • /
    • pp.216-223
    • /
    • 2009
  • The relation between temperature and hydrogen desorption on variation in output was investigated for the metal hydride canister. For this study, an AB$_5$ type alloy were chosen as a hydrogen storage material in the metal hydride canister. And application to the single proton exchange membrane fuel cell was evaluated. As the results, the hydrogen desorption was linearly increased as the temperature was risen. In addition, metal hydride canister heating was able to correspond the variation of load as power request in the PEMFC system.

Compression-Compression Fatigue Behavior of Al-Si-Ca alloy Foams (Al-Si-Ca 합금 폼의 압축 피로 거동)

  • Lee, Chang-Hun;Ha, San;Kim, Am-Kee;Jeong, Gil-Do
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.190-195
    • /
    • 2004
  • The compression-compression fatigue properties of the closed cell Al-Si-Ca alloy foams have been studied. The monotonic and cyclic compressive properties were compared with each other and the fatigue stress-life (S-N) curves were presented. In compression-compression fatigue, the crushing was found to initiate in a single band which broadens gradually with additional fatigue cycles. Progressive shortening of the specimen took place due to a combination of low cycle fatigue failure and cyclic ratcheting which is in accordance with the findings of previous researchers [1-3]. Young's modulus of the foam was found to decrease with the increasing strain in case of fatigue test however in case of monotonic compression test the value of Young's modulus increased with the strain (number of cycles). The endurance limit on the basis of $10^{7}$ cycles obtained by extrapolating the experimental results were 0.98 MPa and 1.70 MPa for load ratios 0.1 and 0.5 respectively which are 34 % and 59 % of the plateau stress.

  • PDF

Implementation and evaluation of the BCG measurement system for non-constrained health monitoring (무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

Performance Evaluation of Controlling Seismic Responses of a Building Structure with a Tuned Liquid Column Damper using the Real-Time Hybrid Testing Method (실시간 하이브리드 실험법을 이용한 동조액체기둥감쇠기가 설치된 구조물의 지진응답 제어성능 평가)

  • Chung, Hee-San;Lee, Sung-Kyung;Park, Eun-Churn;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.669-673
    • /
    • 2007
  • In this study, real-time hybrid test using a shaking table for the control performance evaluation of a U-shaped TLCD controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a U-shaped TLCD adopted as an experimental part was installed to reduceits response. At first, the force that is acting between a TLCD and building structure is measured from the load cell attached on shaking table and is fed-back to the computer to control the motion of shaking table. Then, the shaking table is so driven that the error between the interface acceleration computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the shaking table. The control efficiency of the TLCD used in this paper is experimentally confirmed by implementing this process of shaking table experiment on real-time.

  • PDF

Road Noise Prediction Based on Frequency Response Function of Tire Utilizing Cleat Excitation Method (크리트 가진법을 이용한 타이어특성에 따른 로드노이즈 예측 연구)

  • Park, Jong-Ho;Hwang, Sung-Wook;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.8
    • /
    • pp.720-728
    • /
    • 2012
  • It is important for identification of noise and vibration problem of tire to consider influence of interaction between road and tire. A quantification of road noise is a challenging issue in vehicle NVH due to extremely complicated transfer paths of road noise as well as the difficulty in an experimental identification of input force from tire-road interaction. A noise caused by tire is divided into road noise(structure-borne noise) and pattern noise(air-borne noise). Pattern noise is caused by pattern shape of tire, which has larger than 500 Hz, but road noise is generated by the interactions between a tire and a vehicle body. In this paper, we define the quantitative analysis for road noise caused by interactions between tire and road parameters. For the identification of road noise, the chassis dynamometer that is equipped $10mm{\times}10mm $ square cleat in the semi-anechoic chamber is used, and the tire spindle forces are measured by load cell. The vibro-acoustic transfer function between ear position and wheel center was measured by the vibro-acoustic reciprocity method. In this study three tires with different type of mechanical are used for the experiment work.

A Study on the Development and Precise Performance Test of a Screw Type Flowmeter (스크류 유량계의 개발 및 정밀 성능평가에 관한 연구)

  • Hwang, Jong-Dae;Oh, Ji-Young;Jung, Yoon-Gyo;Lee, Sang-Ryul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.87-95
    • /
    • 2009
  • This research introduces the efficient modeling and manufacturing method using reverse engineering combined with rotational simulation of a pair of screw and mill-turn machining realized a proposed NC program. Because previously developed model had insufficient flow measuring accuracy, we considered that matter in the aspect of method of modeling and performance test. For that reason we modified the modeling which could minimize a gab between male and female screw, and developed precise tester which consists of constant tank, flowmeter and load cell, etc., and then conducted the test for defining characteristic and accuracy of flowmeter and repeated same test 5-times. Consequently we could obtain satisfied measuring accuracy and reproducibility indicated in the catalog of master model. Hence we give our conclusion as to the validity of developing accurate screw type flowmeter using the proposed process such as reverse engineering, mill-turn machining and precise performance test.