• Title/Summary/Keyword: LIGHT

Search Result 31,946, Processing Time 0.051 seconds

Effects of Light Pollution from Mobile Digital Devices on Sleep and Circadian Rhythms (모바일 디지털 기기로 인한 빛공해가 수면과 일주기 리듬에 미치는 영향)

  • Lee, Youn-Jung;Cho, Chul-Hyun;Lee, Heon-Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Mobile digital devices are very familiar and useful devices in the daily life of modern people, and are used for various tasks such as communication, reading, writing, and playing media. As the use of mobile digital devices has become more prevalent, user time has also been increasing. In particular, the number of people who use digital devices before sleep is growing. The light pollution associated with these devices is classified into four categories: urban sky glow, glare, light trespass, and clutter. The pattern in which modern people use digital devices corresponds to light pollution caused by light trespass and clutter from light exposure to artificial light at night. The light pollution caused by digital devices can cause melatonin secretion suppression, delayed sleep onset, reduction of sleepiness before bedtime, and periodic rhythm and cognitive function disturbances. In addition, a study of children and adolescents showed there may be disturbances in the sleep-wake cycle and circadian rhythm, deterioration of sleep quality, and daytime fatigue due to light pollution caused by artificial light at night from mobile digital devices. A multi-faceted research effort is also necessary to investigate the healthy use of mobile digital devices based on research evidence and insights with an accurate evaluation of the influence of mobile digital devices as a form of light pollution.

A STUDY ON THE SHEAR BOND STRENGTH BY PLASMA ARC CURING SYSTEM FOR BRACKET BONDING (Plasma arc curing system을 이용한 브라켓의 접착에 관한 연구)

  • Kim, Jung-Yoon;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.638-642
    • /
    • 2001
  • Recently, plasma arc curing system for curing resin composites has been introduced. This is characterized by a high output of light energy, which has the advantage of reducing the chair time and thereby making the treatment more comportable for the patients as well as for the dentist. The purpose of this study was to compare the shear bond strengths of light-cured orthodontic adhesive polymerized with conventional halogen light and plasma arc light. The 2 curing devices used were the XL3000 (3M, USA) conventional curing light and the Flipo (LOKKI, France) plasma arc light. The results from the present study can be summarized as fellows; 1. The mean shear bond strength for three groups were quite similar for 50 second conventional light group, 2 second plasma arc curing light group, 5 second plasma arc curing light group. 2. There was no statistically significant difference for three groups(p>0.05).

  • PDF

A STUDY ON BONDING STRENGTH OF DENTAL AMALGAM TO GLASS IONOMER CEMENT FOLLOWING SURFACE TREATMENT (글라스아이오노머 시멘트 표면 처리에 따른 치과용 아말감의 전단 결합 강도에 관한 연구)

  • Shin, Young-Joo;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.217-230
    • /
    • 1994
  • The purpose of this study was to assess the 24-hour shear bond strength of amalgam to glass ionomer cement, using five different intermediaries. The intermediaries used in this study were Scotchbond 2 (light curing dentin adhesive), Panavia (resin cement), liquid' of glass ionomer cement (chemical curing & light curing), and uncured mixture of light curing glass ionomer cement. This study was operated with 48 specimens devided into 6 groups. The experimental groups are as follows: Group 1 : Bonded Amalgam to chemical curing glass ionomer cement with liquid of chemical curing glass ionomer. Group 2 : Bonded Amalgam to light curing glass ionomer cement with liquid of chemical curing glass ionomer. Group 3: Bonded Amalgam to light curing glass ionomer cement with resin cement. Group 4: Bonded Amalgam to light curing glass ionomer cement with light curing dentin adhesive. Group 5: Bonded Amdlgam to light curing glass ionomer cement with liquid of light curing glass ionomer. Group 6: Bonded Amalgam to light curing glass ionomer cement with uncured mixture of light curing glass ionomer cement. 30 minutes after amalgam condensation, all specimens were stored for 24 hours in water at $37^{\circ}C$ and tested with Instron (1122). The following results obtained: 1. The shear bond strength of group 6 was higher than those of the other groups (46.7 kgf/$cm^2$, p<0.05). 2. The shear bond strength of resin cement intermediary group was lower than that of the group using uncured mixture of light curing glass ionomer cement. 3. The results of group 1 and group 2 were different, even though the inter-me diaries used were same. 4. Intermediary of Group 5 did not show complete set in Scanning Electromicroscopic examination. 5. Light-curing dentin adhesive did not show any bonding ability to amalgam.

  • PDF

Light Collection Efficiency of Large-volume Plastic Scintillator for Radiation Portal Monitor (방사선 포털 모니터용 대용적 플라스틱 섬광체 내부 빛 수집 효율 평가)

  • Lee, Jin Hyung;Kim, Jong Bum
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.157-165
    • /
    • 2017
  • In this paper, we calculate the light photons collection efficiency of large-volume plastic scintillation detector mainly used for radiation portal monitor (RPM). A Monte Carlo light photon transport code, DETECT2000, were used to quantitatively evaluate light collection efficiency of plastic scintillation detector. DETECT2000 calculated the placement of light collection efficiency based on the energy spectrum. We calculated the light collection efficiency relative to the position of the energy spectrum that proportional to the placement of the source. The $850{\times}285{\times}65mm^3$ size of polyvinyl toluene (PVT) scintillator was used for measurements. Through DETECT2000 simulation, the light collection efficiency of $5{\times}5$ arrays were calculated and verification was performed by comparing with experimentally measured. And then, the corrected MCNP simulation by applying the light collection efficiency in $21{\times}13$ arrays was compared and analyzed. Comparing the Monte Carlo simulation with measured results, it shows an average difference of 10.1% in $5{\times}5$ arrays. Particularly, about twice of the difference was found in the edge of first column, which coupled with PMT. In whole $5{\times}5$ array, the overall ratio was the same except for the first column. And then comparing the energy spectra of the $21{\times}13$ array with and without the light collection efficiency, it shows a difference of 6.69% in Compton edge area. The DETECT2000 based light collection efficiency simulation showed well agreement with the point source experiment. And comparing with measured energy spectra, we could compare the differences according to whether or not the light collection efficiency was applied. As a results, it is possible to increase the accuracy and reliability of Monte Carlo simulation results by pre-calculating the light collection efficiency according to the PVT geometry by using the DETECT2000.

A Methodology to Produce Light Pollution Map and Diagnose Urban Nightlight Conditions Using International Space Station Nighttime Image Data (국제 우주정거장 촬영 야간 이미지 데이터를 활용한 빛지도 제작과 빛공해 진단기법)

  • Kim, Jung-A;Cheon, Sang-Hyun
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.12
    • /
    • pp.13-24
    • /
    • 2018
  • Recently, light pollution has become a serious environment issue caused by excessive uses of artificial light. Central and local governments have made efforts to manage light pollution and mitigate light pollution damages. Developing methods to diagnose light pollution is critical to effectively monitor light pollution conditions in Seoul. This study develops a methodology to create a map that presents the status of light pollution in Seoul, using International Space Station(ISS) night-time images. Through the map, we evaluated the areas that show high levels of light intensity and found out local characteristics of light intensity; Commercial area, office building concentrated area, and large sports facilities. The result of study provides basic understanding to present a new way for monitoring light pollution in urban sites.

A Study on Lighting Environmental Evaluation of Senior Welfare Centers Based on biophilia

  • Yang, So Yeon;Lee, Tae Kyung
    • Architectural research
    • /
    • v.22 no.4
    • /
    • pp.123-133
    • /
    • 2020
  • Light is an essential environmental element for elderly people to do various activities. At senior welfare centers, healthy indoor lighting is especially necessary because the facilities are used by the elderly to perform their mostly indoor activities. The purpose of this study is to evaluate light environments at senior welfare centers for well-being lighting characteristics. We based the study on the 'Biophilia' theory, a concept related to health from happiness. Thus, this study is mainly based on literary review and survey research. For this, we conducted a location focused field study to identify the current state of the lighting environments at senior welfare centers in Busan, South Korea. First, we constructed structural questionnaire to evaluate lighting environment based on 'Light and Space' biophilia theory. Then, to survey subjective evaluation, the participant of research included total of 122 senior welfare center users. Based on the results of this research, the conclusions are as follows; 1) overall, it seems that the overall result of the light environmental evaluation seems to be high because the evaluated facilities in the case survey in large-scale were recently built elderly welfare centers. 2) most of the healing design elements are focused on the introduction of natural light and psychological influence. The satisfaction with actual natural light is evaluated to be high. Although shadow and reflected light are very important in discrimination and recognition of indoor space and wayfinding, the evaluation of reflected light and shadow was low for the study. 3) items that are related to the functionality of the light were highly evaluated, while the items that are related to the spatiality of the light were rated poorly. This study has its significance when examining the effects of light environments within the welfare center form of the perspective of senior citizens. It can be referenced when reconsidering the recognition of light environment as a major consideration factor to establish a desirable senior welfare center environment.

Fuel Qualities of Different Biodiesels in the Gun Type Burner (바이오디젤의 난방유로서의 연료특성)

  • Kim, Y.J.;Kang, Y.K.;Kang, K.C.;Ryou, Y.S.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.2
    • /
    • pp.124-129
    • /
    • 2008
  • In this study, fuel qualities including kinematic viscosity and pour point in the various temperature, calorific value and combustion characteristics of two biodiesels based on the soybean and waste oil blended with light oil were investigated and discussed in order to figure out to confirm fuel compatibility taking the place of light oil in the hot air heater or boiler. As biodiesel content ratio increased calorific value of biodiesel decreased, and the difference was 13% between 100%-biodiesel and light oil. In general, pour points of the biodiesels were higher than light oil, and as biodiesel content ratio increased pour point increased. About 15 cSt was the pour point of biodiesels and light oil, which occurred at 3 to $4^{\circ}C$ in the biodiesels and $-25^{\circ}C$ in the light oil. Flame dimensions of biodiesels and light oil were almost same at the same combustion condition in the burner of the hot air heater. CO concentrations in the exhaustion gas were far lower than those of the light oil. Though pour point of biodiesel is a little inferior to light oil, still biodiesel can be an alternative fuel substituting for light oil in combustion system without much modifying the current oil combustion mechanism.

Effect of Muscle pH and Display Conditions on Surface Color in Hanwoo (Korean Native Cattle) Beef

  • Lee, S.K.;Kim, Y.S.;Kim, J.Y.;Song, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.3
    • /
    • pp.365-371
    • /
    • 2001
  • The effects of light exposure and light intensity on surface color of Hanwoo (Korean native cattle) beef and color stability of fresh normal and DFD (dark, firm, dry) muscles during 7 days at $4{\pm}1^{\circ}C$ under three display conditions (Dark, Light1000 and Light3000) were investigated. The $L^*$, $a^*$, $b^*$, $C^*$ values and R630-R580 were significantly (p<0.05) higher in normal beef than in DFD beef. The $a^*$, $b^*$, $c^*$ values and R630-R580 of normal beef increased during the first day of display except Light3000 group, then gradually decreased over time. The surfaces of Hanwoo beef accumulated more metmyoglobin in the light than in the dark. Also, the rate of decrease in redness during refrigerated storage was enhanced by light exposure and increase in light intensity. Discolorations were more rapid in DFD beef than normal beef. Increasing light intensity promoted not only discoloration but also lipid oxidation. Therefore storage in the dark is effective in retarding the formation of a brown color in Hanwoo beef.

Comparative Luminance and Correlated Color Temperature of Work-place by a Fluorescent and LED Light Sources (LED광원과 형광광원에 의한 작업면의 휘도 및 색온도 비교)

  • Baik, Seung heon;Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.21-26
    • /
    • 2008
  • According to the tendency of energy efficiency and environment-friendly chracteristics, demend of High-efficiency lighting using LED(Light Emitting Diode)are being increased actively and applied in various fields. However, In order to adequate application of LED light sources, it is necessary to lighting environment and luminous characteristics of LED light sources. This Study aims to characterize the work-plane lighting environment by LED light sources comparing with fluorescent light sources which are widely used. For the sake of this study, a fluorescent light source and 5 LED light sources were introduced and luminance and correlated color temperature were measured to evaluate luminance contrast. The experimental model is Mock-up which is $4.9m{\times}7.2m$ with a height of 2.9m. The test room was set up partition and desks. Luminance and correlated color temperature were measured work-plane on the desk which was set up local lighting by the Radiant Imaging ProMetric 1400. The optical characteristics data of LED can give a lot of advantages to design LED lighting appliances. Hereafter, the object of research will be conducted to evaluate effects of LED light sources on working performance, survey of visual performance, preference and physiology of subjects.

A Study on the Design Criteria of Photobioreactor for the Efficiency of Light-Utilization (빛 이용효율 향상을 위한 광생물반응기 설계 기준에 관한 연구)

  • 류현진;이진석;오경근
    • KSBB Journal
    • /
    • v.19 no.4
    • /
    • pp.257-262
    • /
    • 2004
  • Recently, there is a growing interest in microalgae and the use of microalgae focused on the production of various high value metabolite used in food, pharmaceuticals and cosmetics. The key limiting factor in high density algal cultivation is the light and algal growth is defined by light intensity and light penetration depth into the culture medium. The effect of light with various light paths, S/V ratios, light intensities, and 50% duty cycle on the growth of microalgae was examined to enhance microalgal biomass productivity and photosynthetic efficiency. We confirmed that the utilization of efficient light energy was obtained from 4 cm of diameter, 57.6% of S/V ratio, 62 ${\mu}$mol/㎡/s of light intensity.