• Title/Summary/Keyword: LC-MS-MS

Search Result 1,321, Processing Time 0.022 seconds

Simultaneous analysis and occurrences of six pharmaceuticals in surface water by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 하천수 중 잔류 6종 의약물질의 동시분석 및 모니터링)

  • Kim, Byung-Ju;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.572-578
    • /
    • 2010
  • The extraction/clean-up and concentrating of pharmaceuticals from surface water were performed by HLB (Hydrophilic-Lipophilic Balanced) cartridge. The method allows for the simultaneous determination of six pharmaceuticals by HPLC/ESI(+)-MS/MS. Recoveries of the pharmaceutical were between 71.1 to 92.6% (except fenbendazole) and the overall variability of the method was below 11.2% (RSD). The calibration curves for the pharmaceuticals from blank surface water showed good linearities (above $r^2$ = 0.99) in the concentration range of 0.007~1.2 ng/mL. The limit of detection (LOD) and the limit of quantification (LOQ) were 7.2~128.7 pg/mL and 23.8~429.1 pg/mL, respectively. The present analytical method can be useful for monitoring residual pharmaceuticals in surface water and other aquatic samples. High concentrations of iopromide and fenbendazole were detected in a few samples of surface water.

A Survey of Zearalenone in Beans Using High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FLD) and Ultra Performance Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) (HPLC-FLD 및 LC-MS/MS에 의한 두류 중 제랄레논 오염실태 조사)

  • Jang, Mi-Ran;Lee, Chang-Hui;Lee, Hyo-Jeong;Kim, Ji-Yeon;Son, Sang-Hyeok;Sin, Chun-Sik;Kim, So-Hui;Kim, Dae-Byeong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.354-359
    • /
    • 2008
  • A survey for zearalenone contamination was conducted on 27 soy bean samples, 27 red bean samples, 16 black bean samples, 19 seoritae samples, 14 seomoktae samples, for a total of 127 commercial Korean samples. Zearalenone was quantified by the immunoaffinity column clean-up method with high performance liquid chromatography-fluorescence detection (HPLC-FLD), and was confirmed by liquid chromatography tandem mass spectrometry(LC-MS/MS). The limits of detection and quantification were $2.0{\mu}g/kg$ and $6.0{\mu}g/kg$, respectively. The recovery in the beans ranged from 82.2 to 98.4%. According to HPLC-FLD, zearalenone was detected in 13 samples (10.2% incidence), including 1 soybean and 12 red bean samples. The zearalenone contamination levels were in the range of 8.01${\sim}38.98{\mu}g/kg$. Finally, LC-MS/MS analysis was conducted in the contaminated samples to verify the results of HPLC-FLD. The LC-MS/MS results confirmed the presence of zearalenone in all 13 samples. The contamination level was lower than that of EU, which is below $100{\mu}g/kg$ for raw grains.

Qualitative Analysis of Phenolic Substances in Artemisia capillaris by LC-MS (LC-MS에 의한 사철쑥에 존재하는 페놀성 화합물의 정성분석)

  • Nugroho, Agung;Lim, Sang-Cheol;Park, Hee-Juhn
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.4
    • /
    • pp.302-307
    • /
    • 2012
  • The herb of Artemisia capillaris in Chinese medicine is used to treat hepatic diseases. In this research, qualitative analysis was performed using a UPLC/Q-TOF-ESI-MS/MS method for rapid identification of phenolic substances from A. capillaris: three caffeoylquinic acids (chlorogenic acid, 3,5-di-O-caffeoylquinic acid, and 4,5-di-O-caffeoylquinic acid), three flavonoids (hyperoside, isorhamnetin 3-O-robinobioside and quercetin) and three prenylated coumarins (6,8-diprenylumbelliferone, cedrelopsin and osthol) were identified. The three prenylated coumarins have not been reported from A. capillaris.

A New Analytical Method for Erythromycin in Fish by Liquid Chromatography/Tandem Mass Spectrometry

  • Park, Mi-Jung;Park, Mi-Seon;Lee, Tae-Seek;Shin, Il-Shik
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.508-513
    • /
    • 2008
  • Erythromycin has been used to treat Streptococosis, Edwardsiel1osis, Vibriosis, Bacterial enteritis in the cultured fish. In this study, a rapid and effective erythromycin analysis method with new sample treatment protocol and liquid chromatography/tandem mass spectrometry (LC/MS/MS) system for fish products was developed. For the erythromycin extraction from fish muscle, the solvent mixture composed of 0.2% meta-phosphoric acid and methanol (6:4) showed good recovery rate, and the optimum extraction solvent volume was 20 mL. Erythromycin detection using LC/MS/MS were carried out under electro spray ionization (ESI) positive condition and erythromycin mass value 576.2 and 157.9. And the detection limit of the established method was 0.005 mg/kg in fish products. The recovery rate of the developed method applied to the fish species were as following, olive flounder, $87.6{\pm}5.0%$; black rockfish, $87.2{\pm}6.4%$; eel, $85.2{\pm}4.8%$; and rainbow trout, $86.0{\pm}6.2%$. In the established method in this study, the correlation of coefficient values ($R^2$) of erythromycin calibration curve (n=11) was 0.9998.

Simultaneous Determination and Occurrences of Pharmaceuticals by Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) in Environmental Aqueous Samples

  • Koo, So-Hyun;Jo, Cheon-Ho;Shin, Sun-Kyoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1192-1198
    • /
    • 2010
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in the aquatic environment. Many pharmaceuticals are not completely removed during wastewater treatment, leading to their presence in wastewater treatment effluents, rivers, lakes, and ground water. Here, we developed analytical methods for monitoring ten pharmaceuticals from surface water by LC/ESI-MS/MS. For sample clean-up and extraction, MCX (mixed cation exchange) and HLB (hydrophilic-lipophilic balance) solid-phase extraction (SPE) cartridges were used. The limits of detection (LOD) in distilled water and the blank surface water were in the range of 0.006 - 0.65 and 1.66 - 45.05 pg/mL, respectively. The limits of quantitation (LOQ) for the distilled water and the blank surface water were in the range of 0.02 - 2.17 and 5.52 - 150.15 pg/mL, respectively. The absolute recoveries for fortified water samples were between 62.1% and 125.4%. Intra-day precision and accuracy for the blank surface water were 2.9% - 24.1% (R.S.D.) and -16.3% - 16.3% (bias), respectively. In surface wastewater near rivers, chlortetracycline and acetylsalicylic acid were detected frequently in the range of 0.017 - 5.404 and 0.029 - 0.269 ng/mL, respectively. Surface water near rivers had higher levels than surface water of domestic treatment plants.

Optimization of Enzyme Digestion Conditions for Quantification of Glycated Hemoglobin Using Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry

  • Jeong, Ji-Seon
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.52-56
    • /
    • 2014
  • Glycated hemoglobin (HbA1c) is used as an index of mean glycemia over prolonged periods. This study describes an optimization of enzyme digestion conditions for quantification of non-glycated hemoglobin (HbA0) and HbA1c as diagnostic markers of diabetes mellitus. Both HbA0 and HbA1c were quantitatively determined followed by enzyme digestion using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) with synthesized N-terminal hexapeptides as standards and synthesized isotope labeled hexapeptides as internal standards. Prior to quantification, each peptide was additionally quantified by amino acid composition analysis using ID-LC-MS/MS via acid hydrolysis. Each parameter was considered strictly as a means to improve digestion efficiency and repeatability. Digestion of hemoglobin was optimized when using 100 mM ammonium acetate (pH 4.2) and a Glu-C-to-HbA1c ratio of 1:50 at $37^{\circ}C$ for 20 h. Quantification was satisfactorily reproducible with a 2.6% relative standard deviation. These conditions were recommended for a primary reference method of HbA1c quantification and for the certification of HbA1c reference material.

Proteomic Evaluation of Cellular Responses of Saccharomyces cerevisiae to Formic Acid Stress

  • Lee, Sung-Eun;Park, Byeoung-Soo;Yoon, Jeong-Jun
    • Mycobiology
    • /
    • v.38 no.4
    • /
    • pp.302-309
    • /
    • 2010
  • Formic acid is a representative carboxylic acid that inhibits bacterial cell growth, and thus it is generally considered to constitute an obstacle to the reuse of renewable biomass. In this study, Saccharomyces cerevisiae was used to elucidate changes in protein levels in response to formic acid. Fifty-seven differentially expressed proteins in response to formic acid toxicity in S. cerevisiae were identified by 1D-PAGE and nano-liquid chromatography-tandem mass spectrometry (nano-LC-MS/MS) analyses. Among the 28 proteins increased in expression, four were involved in the MAP kinase signal transduction pathway and one in the oxidative stress-induced pathway. A dramatic increase was observed in the number of ion transporters related to maintenance of acid-base balance. Regarding the 29 proteins decreased in expression, they were found to participate in transcription during cell division. Heat shock protein 70, glutathione reductase, and cytochrome c oxidase were measured by LC-MS/MS analysis. Taken together, the inhibitory action of formic acid on S. cerevisiae cells might disrupt the acidbase balance across the cell membrane and generate oxidative stress, leading to repressed cell division and death. S. cerevisiae also induced expression of ion transporters, which may be required to maintain the acid-base balance when yeast cells are exposed to high concentrations of formic acid in growth medium.

Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS

  • Jeong, Jee-Yeon;Lee, Ji-Hyun;Kim, Eun-Young;Kim, Pan-Gyi;Kho, Young-Lim
    • Safety and Health at Work
    • /
    • v.2 no.1
    • /
    • pp.57-64
    • /
    • 2011
  • Objectives: Although phthalates like dibutyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) are commonly used as plasticizers and their metabolites are especially suspected of reproductive toxicity, little is known about occupational exposure to those phthalates. The aim of this study was to assess the utility of measuring the metabolite concentrations of DBP and DEHP in serum and urine samples as an indicator of occupational exposure to those phthalates. Methods: Phthalate metabolites were analyzed by using column-switching high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS). Results: We detected phthalate metabolites in serum and urine matrices at approximately 10-fold lower than the limit of detection of those metabolites in the same matrix by LC-MS/MS without column switching, which was sufficient to evaluate concentrations of phthalate metabolites for industrial workers and the general population. Conclusion: The accuracy and precision of the analytical method indicate that urinary metabolite determination can be a more acceptable biomarker for studying phthalate exposure and adverse health outcomes.

Quantitative Analysis of the Twenty Marker Components in Gwakhyangjeonggi-san using Ultra-Performance Liquid Chromatography with Mass Spectrometer (LC-MS/MS를 이용한 곽향정기산(藿香正氣散) 추출물 중 20종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.2
    • /
    • pp.113-120
    • /
    • 2014
  • Generally, Gwakhyangjeonggi-san has been used for treatment of diarrhea-predominant irritable bowel syndrome. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was established for the simultaneous quantification of marker compounds 1-20 in Gwakhyangjeonggi-san water extract. All analytes were separated by gradient elution using two mobile phases on a UPLC BEH $C_{18}$ ($100{\times}2.1mm$, $1.7{\mu}m$) column and maintained at $45^{\circ}C$. The injection volume was $2.0{\mu}L$ and the flow rate was 0.3 mL/min with detection at mass spectrometer. Regression equations of the compounds 1-20 were acquired with $r^2$ values ${\geq}0.9950$. The values of limit of detection and quantification of all analytes were 0.01-2.79 ng/mL and 0.03-8.37 ng/mL, respectively. The amounts of the compounds 1-20 in Gwakhyangjeonggi-san water extract were not detected $-3,236.67{\mu}g/g$. The established LC-MS/MS methods will be valuable to improve quality control of traditional herbal formula, Gwakhyangjeonggi-san.

Simultaneous Quantification of 13 Ginsenosides by LC-MS/MS and its Application in Diverse Ginseng Extracts

  • Jo, Jung Jae;Cho, Pil Joung;Lee, Sangkyu
    • Mass Spectrometry Letters
    • /
    • v.9 no.2
    • /
    • pp.41-45
    • /
    • 2018
  • Ginseng (Panax ginseng Meyer) has been used as traditional herbal drug in Asian countries. Ginsenosides are major components having pharmacological and biological efficacy like anti-inflammatory, anti-diabetic and anti-tumor effects. To control the quality of the components in diverse ginseng products, we developed a new quantitative method using LC-MS/MS for 13 ginsenosides; Rb1, Rb2, Rc, Rd, Re, Rf, 20(S)-Rh1, 20(S)-Rh2, Rg1, 20(S)-Rg3, F1, F2, and compound K. This method was successfully validated for linearity, precision, and accuracy. This quantification method applied in four representative ginseng products; fresh ginseng powder, white ginseng powder, red ginseng extract powder, and red ginseng extract. Here the amounts of the 13 ginsenosides in the various type of ginseng samples could be analyzed simultaneously and expected to be suitable for quality control of ginseng products.