• Title/Summary/Keyword: L20 method

Search Result 2,327, Processing Time 0.033 seconds

Production of L-Tryptophan by Enzymatic Processes (효소공정에 의한 트립토판 생산)

  • 이인영;안경섭;김의환;이선복
    • Microbiology and Biotechnology Letters
    • /
    • v.20 no.1
    • /
    • pp.73-78
    • /
    • 1992
  • - Enzymatic synthesis of L-tryptophan(Trp) using E. coli tryptophanase has been investigated. In order to reduce the substrate inhibition by indole and to increase the product yield of L-tryptophan three different approaches have been made in this work. First, indole was intermittently fed to the reaction mixture in order to control the indole concentration at lower level. When 15 mM of indole was used as a total amount of substrate, conversion yield of 80% has been obtained with intermittent feeding while only 20% of indole was converted into L-tryptophan by conventional batch operation, The second method employed in this work was the use of cyclohexane-phosphate buffer organic two-phase system. In this system, indole was mainly partitioned into the organic-solvent phase and therefore substrate inhibition was expected to be reduced. L-Tryptophan production in organic two-phase system was, however, unexpectedly lower than that obtained in aqueous buffer solution. As a third method cyclodextrins have been added to the aqueous reaction mixture. It was found that the addition of $\beta$-cyclodextrin enhanced the tryptophan synthesis noticeably while $\alpha$-cycfodextrin showed little effect on tryptophan production.

  • PDF

Effect of sampling volume on the breakthrough of charcoal tube during vinyl chloride monomer sampling (공기중 염화비닐단량체의 포집시 공기 포집량이 파과에 미치는 영향)

  • Yoon, Jon Jung;Lim, Nam Gu;Kim, Chi Nyun;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.241-248
    • /
    • 2001
  • The main factors of breakthrough are known to sampling time, flow rate, concentration of the sample, temperature, humidity, and the physical characteristics of the solid sorbent tube. However, no study has been reported the effect of temperature and sampling volume on the breakthrough of acharcoal tube during vinyl chloride monomer (VCM) sampling. The objective of this study is to suggest the optimal sampling condition during VCM sampling based on National Institute for Occupational Safety and Health (NIOSH) method. To evaluate adequate sampling volume for VCM without breakthrough, volume of 1, 2, 3, 4, and 5 L each from VCM of 1, 5, 10, 15, and 20ppm at flow rate of 0.05 L/min were sampled in $22^{\circ}C$ and $40^{\circ}C$. At $22^{\circ}C$, in the case of 1, 5, 10, and 15ppm, VCM was adsorbed completely in first section of charcoal tube regardless of sampling volume. But in 20ppm, detection rates are 99.56% in first section and 0.44% in second section. At $40^{\circ}C$ of 1ppm, VCM was adsorbed completely in first section. In 10, 15, and 20ppm, detection rates of second, third, and forth sections were decreased significantly by reduction of sampling volume. In determination of breakthrough based on NIOSH method, no breakthrough was occurred in 20ppm at $22^{\circ}C$. At $40^{\circ}C$, breakthrough was occurred in 10, 15, and 20ppm when sampling volume was 5L. Although no breakthrough was occurred when sampling volume was 3L. Finally, in environment of temperature around $22^{\circ}C$, breakthrough may not occurred up to 20ppm during sampling for VCM. During sampling for VCM in environment of temperature around $40^{\circ}C$, no breakthrough occurred in 1-5ppm and 10-20ppm when sampling volume is 5L and 3L respectively. This result suggests that the sampling volume should be considered when VCM sampling under hot conditions (> $22^{\circ}C$) by the NIOSH method No. 1007.

  • PDF

Serum Alpha-Fetoprotein Levels in Health Checkup Adults (건강 검진자들의 혈청 Alpha-Fetoprotein 농도)

  • Kim, Yoohyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.40 no.2
    • /
    • pp.86-93
    • /
    • 2008
  • This study was performed to investigation of the serum alpha-fetoprotein (AFP) levels in healthy adults. A total of 2,160 (male 1,415, female 745) health checkup adults were examined for AFP levels by chemiluminescence immunoassay (CLIA) method, during the period from September, 2007 to August, 2008. The mean serum AFP level was 2.168 (0.605~20.35) ng/mL, and it was 2.309 (0.605~20.35) ng/mL in male, 1.906 (0.605~10.36) ng/mL in female, respectively. 1,816 (male 1,109, female 709) healthy adults were screened for the absence of viral hepatitis and normal alanine amino transferase (ALT) levels. The mean serum AFP level of healthy adult was 2.041 (0.605~7.83) ng/mL, and it was 2.181 (0.605~7.83) ng/mL in male, 1.822 (0.605~6.55) ng/mL in female, respectively. Serum AFP increased with age group, there was a higher level in male compared to female. These results suggests that the use of reference value of AFP in healthy adults in the Jeonbuk. With the reference value now defined, it becomes possible to compare levels in different populations.

  • PDF

Adaptive Control of D.C. Motor Speed Using W.L.S. Algorithm (W.L.S. 알고리즘을 사용한 직유전동기 속도의 적응제어)

  • Park, Jun;Kwon, Key-Ho;Choi, Kye-Keun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.5
    • /
    • pp.31-36
    • /
    • 1983
  • The indirect M.R.A.C. method using the W.L.S. algorithm is applied to the speed control of a D.C. motor on the assumption that the motor is the 1-st order, completely controllable and observable, non-minimum phase plant. By the help of M6809 microprocessor system the experiments are performed with respect to the sinusoidal and square reference input. The results show that the speed of a D.C. motor is well controlled by the indirect M.R.A.C. method using W.L.S, algorithm, and that the W.L.S. algorithm is quite suitable to the time-varying plant.

  • PDF

Antioxidant Activity and Standardization of Extraction Solvents of SJ004 (SJ004의 추출용매별 항산화 활성 및 표준화 연구)

  • Lee, Dae-Yeon;Jo, Ju-Hwi;Kim, Wan-Su;Lee, Ho-Sung;Yi, Young-Woo;Park, Sang-In;An, Keon-Sang;Lee, In-Hee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.2
    • /
    • pp.67-75
    • /
    • 2020
  • Objectives SJ004 is a natural herbal medicine that contains Acyranthes japonica Nakai and Eucommia ulmoides Oliver traditionally used for joint and spinal diseases. This study aimed to establish an efficient method of extracting SJ004 to standardize using the yield, high-performance liquid chromatography (HPLC), and antioxidant assay. Methods SJ004 was extracted with distilled water, 70% and 100% of ethyl alcohol (EtOH). The method validation of 20-hydroxyecdysone and pinoresinol diglucoside was determined by HPLC-photo diode array and the content of SJ004 was calculated. The antioxidant activity of each extract was compared and measured using total flavonoids, total phenolic compounds, 2,2-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid), and ferric reducing antioxidant power according to the standard protocol. Results The yield was highest in pure water extract and lowest in 100% EtOH. But, the content of marker compounds indicating 20-hydroxyecdysone and pinoresinol diglucoside was highest in 100% EtOH extract. In the physiological activity measurement using antioxidant activity, 100% ethanol extract was highest. The limit of detection indicating 20-hydroxyecdysone and pinoresinol diglucoside were analyzed 0.33 ㎍/mL, 0.1616 ㎍/mL, and the limit of quantification were analyzed 1.01 ㎍/mL and 0.49 ㎍/mL respectively. Conclusions The experimental results showed that the extraction conditions have a significant effect on content of marker compounds and antioxidant activity. As a result of method validation, SJ004 was standardized by 20-hydroxyecdysone and pinoresinol diglucoside.

Comparison and evaluation of methods for the measurement of total nitrogen in wastewater (고농도 질소함유 폐수의 총질소 분석법 비교·평가)

  • Choi, Sung-Deuk;Chang, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 2007
  • The measurement methods for total nitrogen in wastewater containing a high concentration of nitrogen were evaluated. (1) The UV spectrophotometry, (2) reduction-distillation Kjeldahl, (3) total Kjeldahl nitrogen, and (4) ion chromatography methods were applied. The experimental procedure of the UV spectrophotometric method was simple, but it produced large errors deriving from the dilution of samples and calibration standards. While, the reduction-distillation Kjeldahl method didn't need dilution, but the amount of Devarda's alloy and NaOH lead to large errors up to 50 mg/L. The levels of total nitrogen measured by each method were as follows: reduction-distillation Kjeldahl ($568.6{\pm}38.7mg/L$) > UV spectrophotometry ($527.3{\pm}9.6mg/L$) > total Kjeldahl nitrogen method ($494.7{\pm}21.4mg/L$) > ion chromatography method ($417.9{\pm}7.3mg/L$). Therefore, the reduction-distillation Kjeldahl method is preferred for wastewater with the high concentration of nitrogen. Optimal conditions for each experimental procedure, however, are needed to be confirmed, and the Standard Operation Procedure (SOP) for total nitrogen is required for reliable measurements.

Preliminary Survey of Age and Growth of the Short-necked Clam, Paphia undalate(Born), in Kwangyang Bay, Korea (광양만에 분포하는 농조개, Paphia undalata (Born)의 연령과 성장에 관한 기초연구)

  • 김영혜;장대수;박영철
    • The Korean Journal of Malacology
    • /
    • v.17 no.1
    • /
    • pp.7-12
    • /
    • 2001
  • The age and growth of the short-necked clam, Paphia undalata, was investigated from 546 samples randomly collected in December 2000 in Kwangyang Bay, Korea. Ages were determined from ring radius of shell and the maximum age was observed to be 2 years. The relationship between shell length (SL) and shell height (SH) of Paphia undalata was SL = 0.2105 + 1.7569 $\times$ SH ($R^2$= 0.98), and the shell length (SL)-total weight (TW) relationship was TW = 2.5824 $\times$ 10$^{-4}$ $\times$ S $L^{2.6769}$ ($R^2$= 0.92). The von Bertalanffy growth parameters were estimated by the non-linear method, with values as follows: $L_{\infty}$ = 81.46 mm, K : 0.20/year, $t_{0}$ = -1.19 year. The von Bertalnanffy growth equation was $L_{t}$ = 81.46(1- $e^{-0}$.20(t+1.19)/), $W_{t}$ = 33.68(1- $e^{-0}$.20(t+1.19)/)$^{2.6769}$.

  • PDF

Weighted Support Vector Machines with the SCAD Penalty

  • Jung, Kang-Mo
    • Communications for Statistical Applications and Methods
    • /
    • v.20 no.6
    • /
    • pp.481-490
    • /
    • 2013
  • Classification is an important research area as data can be easily obtained even if the number of predictors becomes huge. The support vector machine(SVM) is widely used to classify a subject into a predetermined group because it gives sound theoretical background and better performance than other methods in many applications. The SVM can be viewed as a penalized method with the hinge loss function and penalty functions. Instead of $L_2$ penalty function Fan and Li (2001) proposed the smoothly clipped absolute deviation(SCAD) satisfying good statistical properties. Despite the ability of SVMs, they have drawbacks of non-robustness when there are outliers in the data. We develop a robust SVM method using a weight function with the SCAD penalty function based on the local quadratic approximation. We compare the performance of the proposed SVM with the SVM using the $L_1$ and $L_2$ penalty functions.

Study of Analytical Method for Diesel Fuel Using UV-Spectrophotometer in Water Samples (UV-Spectrophotometer 를 이용한 수중 경유 분석법)

  • Lee, Jong-Sik;Jung, Kwang-Yong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.83-85
    • /
    • 1999
  • This study was conducted to find out analytical method for diesel fuel using uv-spectrophotometer in water samples. The optimum wavelength, detection limit and recoveries for desel fuel extracted with n-pentane were 257nm, $100{\sim}800mg/l$ and $102{\sim}121%$, respectively. This method were stable for measuring concentrations of desel fuel for 1 hour at $20{\pm}1^{\circ}C$ condition.

  • PDF

Evaluation of Antioxidant Status and Correlation among Antioxidant Indices in Female College Students

  • Kim, Jung-Hee;Heajoon Ahn
    • Journal of Community Nutrition
    • /
    • v.5 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • This study was done to evaluate the antioxidant status of female college students by determining their intakes and plasma levels of antioxidnt vitamins (vitamin C, A and E) and total antioxidant status (TAS). Subjects were 46 healthy female college students aged 20 - 29 years. Body composition was determined by a multifrequency bioelectrical impedance analysis. Dietary intakes were examined by 24hr record method and nutrients intakes were analyzed by the Computer Aided Nutritional analysis program for professional (CAN-pro). Plasma vitamin C level were measured by spectrophotometric method and retinol, ${\beta}$-carotene, ${\alpha}$-tocopherol were measured by HPLC. Plasma TAS was measured with a Randox kit using the trolox equivalent antioxidant capacity (TEAC) method. Daily energy and protein intakes of the female college students were 1670.5㎉ (83% of RDA) and 63.3g (115.1% of RDA), respectively. However their intakes of Ca and Fe were below 75% of RDA. Their intakes of vitamin A and C were 596.6 ${\mu}$ gRE (85.2% of RDA) and 71.0mg (101.4% of RDA), respectively. Plasma levels of vitamin C, retinol, ${\beta}$-carotene and ${\alpha}$-tocopherol were 14.7mg/L, 0.7mg/L, 0.2mg/L and 9.1mg/L, respectively which were within normal range. There was no subject with deficiency or marginal level in plasma vitamin A and C. However 1.6% of the subjects had below adequate level in vitamin E. Plasma TAS level was 1.2mmol/L. Correlation data showed that all plasma antioxidant vitamins were positively correlated with plasma TAS. Overall data indicate that the antioxidant status of female college students were pretty good. However it might be necessary to educate them to eat more fruits and vegetables for preventing many chronic diseases in a later life. (J Community Nutrition 5(1) : 13∼20, 2003)