• Title/Summary/Keyword: L20 method

Search Result 2,327, Processing Time 0.034 seconds

The study on the measurement of formaldehyde in saliva and urine by GC-MS (가스크로마토그래프-질량분석기에 의한 타액 및 뇨 중 포름알데하이드 분석법 연구)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.149-154
    • /
    • 2006
  • A gas chromatography-mass spectrometric method was developed for the determination of formaldehyde in urine and saliva. In a 20 mL glass tube, 0.2 mL of urine or saliva was taken. Further, 1.8 mL of 0.1 M HCl, 0.1 mL of 2,000 mg/L 2,4-dinitrophenyl hydrazine and $20{\mu}l$ of 500 mg/L acetone-$d_6$ as internal standard were added in the tube and sealed tightly with cap. The solution was shaken for 20 min at room temperature and extracted using 4 mL of toluene. The extract was concentrated and redissolved with $100{\mu}l$ of acetonitrile, and then measured by gas chromatography-mass spectrometer (selected ion monitoring). The detection limit was 2.0 ng/mL and 0.5 ng/mL in saliva and urine, respectively. The calibration curves showed good linearity with r = 0.997 and 0.998 for saliva and urine, respectively. The method was used to analyze formaldehyde in rat urine after oral exposure. The developed method may be use ful to the monitoring for formaldehyde exposure in human.

The Simultaneous Analysis of Benzene, Toluene, Ethylbenzene, o,m,p-Xylenes and Total Petroleum Hydrocarbons in Soil by GC-FID after Ultra-Sonication

  • Sin, Ho Sang;Gwon, O Seung
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.11
    • /
    • pp.1101-1105
    • /
    • 2000
  • A simultaneous determination method of BTEX (benzene, toluene, ethylbenzene, o,m.p-xylene) and TPH (kerosene, diesel, jet fuel and bunker C) in soil with gas chromatography/flame ionization detection (GC-FID) was described. The effects of extracti on method, extraction solvent, solvent volume and extraction time on the extraction performance were studied. A sonication method was simpler and more efficient than Soxhlet or shaking methods. Sonication with 10 mL of acetone/methylene chloride (1 : 1, v/v) for 10 min was found to be optimal extraction conditions for 20 g of soil. Peak shapes and quantification of BTEX and TPH were excellent, with linear calibration curves over a wide range of 1-500 mg/L for BTEX and 10-5000 mg/L for TPH. Good reproducibilities by sonication were obtained, with the RSD values below 10%. By using about 20 g of soil, detection limits were 0.8 mg/L for BTEX and 10 mg/L for TPH. The advantages of this procedure are the use of simple and common equipment, reduced volumes of organic solvents, rapid extraction periods of less than 20 min, and simultaneous analysis of volatile and semivolatile compounds.

Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

  • Yoon, Yoon Yeol;Kim, Yongcheol
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.142-146
    • /
    • 2020
  • Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial. Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analysis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs. Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was approximately 3.60 ± 0.29 cpm when the 145-mL vial was used and 2.22 ± 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial. Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.

The Analysis of Soil Salinity in Saemangeum Agricultural Land using Spatial Analysis Method (공간분석 기법을 활용한 새만금 농업용지 토양 염도 분석)

  • KIM, Young-Joo;LEE, Geun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.3
    • /
    • pp.37-50
    • /
    • 2019
  • In this study, we analyzed the soil salinity of Saemangeum agricultural land using GIS spatial interpolation method. Dominant soils series of experimental sites were Munpo (coarseloamy, mixed, non-acid, mesic, typically fluvaquents), which was based on the fluvio-marine deposit. Soil samples were periodically collected at 0~20cm and 20~40cm layer from each site. First, the distribution characteristics of EC, ESP, and SAR according to spatial interpolation were analyzed using 142 sample points. Through the error analysis of 143 validation points, the IDW method for EC and SAR, and the Kriging interpolation method for ESP were selected as the optimal interpolation method. Using the optimal interpolation method, the characteristics of EC, ESP, and SAR were analyzed for the change of soil salinity from 2014 to 2016. As a result, EC, ESP and SAR were decreased by 0.26mg/L, 5.97mg/L and 0.73mg/L respectively due to the dilution effect caused by rainfall.

Adhesion control of Campylobacter jejuni in chicken skin using emulsifiers (유화제를 이용한 계육 표면에서 Campylobacter jejuni의 부착 제어)

  • Oh, Do Geon;Kim, Kwang Yup
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.6
    • /
    • pp.670-677
    • /
    • 2020
  • To prevent contamination by Campylobacter jejuni during chicken carcass processing, the effect of emulsifiers on C. jejuni inoculated on chicken skin was investigated using confocal laser scanning microscopy. Among the 8 emulsifiers (SWA-10D, L-7D, M-7D, S-1670, L-1695, P-1670, polysorbate 20, polysorbate 80) tested for antimicrobial activity by the paper disk method, 4 emulsifiers (L-7D, L-1695, polysorbate 20, polysorbate 80) were screened further. Emulsifier L-1695 showed the largest clear zone at a concentration of 200 mg/mL. The 4 emulsifiers subjected to primary screening were screened for heat and pH stability. In the contact surface test, emulsifier L-1695 showed the lowest log CFU/㎠ value on both stainless steel and ceramic surfaces. When emulsifier L-1695 was applied via general and electrostatic spray methods, the number of C. jejuni entrapped inside chicken skin follicles was significantly reduced in both methods. In conclusion, the emulsifier L-1695 could be employed as a microbial detachment agent in the chicken carcass processing industry.

An optimized microwave-assisted extraction method for increasing yields of rare ginsenosides from Panax quinquefolius L.

  • Yao, Hua;Li, Xuwen;Liu, Ying;Wu, Qian;Jin, Yongri
    • Journal of Ginseng Research
    • /
    • v.40 no.4
    • /
    • pp.415-422
    • /
    • 2016
  • Background: Rare ginsenosides in Panax quinquefolius L. have strong bioactivities. The fact that it is hard to obtain large amounts of rare ginsenosides seriously restricts further research on these compounds. An easy, fast, and efficient method to obtain different kinds of rare ginsenosides simultaneously and to quantify each one precisely is urgently needed. Methods: Microwave-assisted extraction (MAE) was used to extract nine kinds of rare ginsenosides from P. quinquefolius L. In this article, rare ginsenosides [20(S)-Rh1, 20(R)-Rh1, Rg6, F4, Rk3, 20(S)-Rg3, 20(R)-Rg3, Rk1, and Rg5] were identified by high performance liquid chromatography (HPLC)-electrospray ionization-mass spectrometry. The quantity information of rare ginsenosides was analyzed by HPLC-UV at 203 nm. Results: The optimal conditions for MAE were using water as solvent with the material ratio of 1:40 (w/v) at a temperature of $145^{\circ}C$, and extracting for 15 min under microwave power of 1,600 W. Seven kinds of rare ginsenosides [20(S)-Rh1, 20(R)-Rh1, Rg6, F4, Rk3, Rk1, and Rg5] had high extraction yields, but those of 20(S)-Rg3 and 20(R)-Rg3 were lower. Compared with the conventional method, the extraction yields of the nine rare ginsenosides were significantly increased. Conclusion: The results indicate that rare ginsenosides can be extracted effectively by MAE from P. quinquefolius L. in a short time. Microwave radiation plays an important role in MAE. The probable generation process of rare ginsenosides is also discussed in the article. It will be meaningful for further investigation or application of rare ginsenosides.

The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT (PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가)

  • Hong, Gun-Chul;Park, Sun-Myung;Jung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.172-176
    • /
    • 2010
  • Purpose: The patients' moves occurred at PET/CT scan will cause the decline of correctness in results by resulting in inconsistency of Attenuation Correction (AC) and effecting on quantitative evaluation. This study has evaluated the utility of reconstruction method using AC position changing method when having inconsistency of AC depending on the position change of emission scan after transmission scan in obtaining PET/CT 3D image. Materials and Methods: We created 1 mL syringe injection space up to ${\pm}2$, 6, 10 cm toward x and y axis based on central point of polystyrene ($20{\times}20110$ cm) into GE Discovery STE16 equipment. After projection of syringe with $^{18}F$-FDG 5 kBq/mL, made an emission by changing the position and obtained the image by using AC depending on the position change. Reconstruction method is an iteration reconstruction method and is applied two times of iteration and 20 of subset, and for every emission data, decay correction depending on time pass is applied. Also, after setting ROI to the position of syringe, compared %Difference (%D) at each position to radioactivity concentrations (kBq/mL) and central point. Results: Radioactivity concentrations of central point of emission scan is 2.30 kBq/mL and is indicated as 1.95, 1.82 and 1.75 kBq/mL, relatively for +x axis, as 2.07, 1.75 and 1.65 kBq/mL for -x axis, as 2.07, 1.87 and 1.90 kBq/mL for +y axis and as 2.17, 1.85 and 1.67 kBq/mL for -y axis. Also, %D is yield as 15, 20, 23% for +x axis, as 9, 23, 28% for -x axis, as 12, 21, 20% for +y axis and as 8, 22, 29% for -y axis. When using AC position changing method, it is indicated as 2.00, 1.95 and 1.80 kBq/mL, relatively for +x axis, as 2.25, 2.15 and 1.90 kBq/mL for -x axis, as 2.07, 1.90 and 1.90 kBq/mL for +y axis, and as 2.10, 2.02, and 1.72 kBq/mL for -y axis. Also, %D is yield as 13, 15, 21% for +x axis, as 2, 6, 17% for -x axis, as 9, 17, 17% for +y axis, and as 8, 12, 25% for -y axis. Conclusion: When in inconsistency of AC, radioactivity concentrations for using AC position changing method increased average of 0.14, 0.03 kBq/mL at x, y axis and %D was improved 6.1, 4.2%. Also, it is indicated that the more far from the central point and the further position from the central point under the features that spatial resolution is lowered, the higher in lowering of radioactivity concentrations. However, since in actual clinic, attenuation degree increases more, it is considered that when in inconsistency, such tolerance will be increased. Therefore, at the lesion of the part where AC is not inconsistent, the tolerance of radioactivity concentrations will be reduced by applying AC position changing method.

  • PDF

R. L. Moore's Moore Method and its meaning in Korea (Robert Lee Moore의 교수법과 한국에서의 의미)

  • Lee, Sang-Gu;Ree, Sang-Wook;Kim, Duk-Sun
    • Journal for History of Mathematics
    • /
    • v.21 no.1
    • /
    • pp.79-96
    • /
    • 2008
  • In early 21st century, universities in Korea has been asked the new roles according to the changes of educational and social environment. With Korea's NURI and Brain Korea 21 project support, some chosen research oriented universities now should produce "teacher of teachers". We look 100 years back America's mathematics and see many resemblances between the status of US mathematics at that time and the current status of Korean mathematics, and find some answer for that. E. H. Moore had produced many good research mathematicians through his laboratory teaching techniques. R. L. Moore was his third PhD students. He developed his Texas/Moore method. In this article, we analyze what R. L. Moore had done through his American School of Topology and Moore method. We consider the meaning that early University of Texas case gives us in PBL(Problem Based Learning) process.

  • PDF

The Effect of $_L$=lysine on Growth Inhibition of Microcystis sp. ($_L$ =lysine에 의한 Microcystis sp.의 선택적 성장억제)

  • 송석환;신규철;한명수;최영길
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.2
    • /
    • pp.216-221
    • /
    • 2003
  • Various physico-chemical and biological methods have been used to remove. cyanobacteria which causes blooms and releases toxin. The purpose of the following experiment is aimed finding out which cyanobacteria are affected by $_L-lysine $ and what concentration of$_L-lysine $ inhibits cyanobacteria. The 20 samples of Microcystis sp. have been tested. To prove the growth inhibition on Microcystis sp., double-layered agar method and microplate method have been used. When the concentration of $_L-lysine $ is as heavy as 100 ${\mu}g\; ml^{-1}$~300 ${\mu}g\; ml^{-1}$, some Microcystis sp. have made halo zone. Some Microcystis sp. have shown so high activity as to be inhibited in their growth by the $_{L}$-lysine of concentration 10 ${\mu}g\; ml^{-1}$ with microplate method. These activities are various in accordance with every species. In additions, the microplate method has been proven to be an easy way which examine the lytic activity on the species of algae.e.