• 제목/요약/키워드: L-shaped Beam

검색결과 42건 처리시간 0.019초

Study on the progressive collapse resistance of CP-FBSP connections in L-CFST frame structure

  • Xiong, Qingqing;Wu, Wenbo;Zhang, Wang;Chen, Zhihua;Liu, Hongbo;Su, Tiancheng
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.437-450
    • /
    • 2022
  • When the vertical load-bearing members in high-rise structures fail locally, the beam-column joints play an important role in the redistribution of the internal forces. In this paper, a static laboratory test of three full-scale flush flange beam-reinforced connections with side and cover plates (CP-FBSP connection) with double half-span steel beams and single L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) was conducted. The influence of the side plate width and cover plate thickness on the progressive collapse resistance of the substructure was thoroughly analyzed. The failure mode, vertical force-displacement curves, strain variation, reaction force of the pin support and development of internal force in the section with the assumed plastic hinge were discussed. Then, through the verified finite element model, the corresponding analyses of the thickness and length of the side plates, the connecting length between the steel beam flange and cover plate, and the vertical-force eccentricity were carried out. The results show that the failure of all the specimens occurred through the cracking of the beam flange or the cover plate, and the beam chord rotations measured by the test were all greater than 0.085 rad. Increasing the length, thickness and width of the side plates slightly reduced the progressive collapse resistance of the substructures. The vertical-force eccentricity along the beam length reduced the progressive collapse resistance of the substructure. An increase in the connecting length between the beam flange and cover plate can significantly improve the progressive collapse resistance of substructures.

800MHz 대역용 L형 급전구조를 이용한 U-Slot 광대역 안테나 설계 및 제작 (The Design and Manufactured of U-Slot Broadband Antenna using L-Shaped 800MHz Band)

  • 김갑기
    • 한국항행학회논문지
    • /
    • 제10권4호
    • /
    • pp.342-347
    • /
    • 2006
  • 본 논문에서는 마이크로스트립 안테나의 좁은 대역폭 문제를 개선하여 CDMA대역을 비롯한, GSM, TRS대역을 통합할 수 있는 800MHz대역 광대역 안테나를 설계하고자 한다. L형 급전구조를 갖고 U-slot을 추가하여 이중 공진 효과를 이용하였다. 또한 이득의 개선을 위해 수직으로 적층 하였다. 설계 및 제작된 안테나의 주파수 대역폭(VSWR 2:1)은 789MHz~1086MHz로 297MHz(33%)의 양호한 특성을 보였으며, 또한 E-평면과 H-평면 모두 이득은 9.4dBi 이상, 3dB 빔폭은 $61^{\circ}$이상의 개선된 특성을 보였다.

  • PDF

L형 급전구조를 이용한 800MHz대 광대역 안테나 설계 (The design of 800MHz band Broadband Antenna using L-Shaped)

  • 김평국;김갑기
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.219-222
    • /
    • 2006
  • 본 논문에서는 마이크로스트립 안테나의 좁은 대역폭 문제를 개선하여 CDMA대역을 비롯한, GSM, TRS대역을 통합할 수 있는 800MHz대역 광대역 안테나를 설계하고자 한다. L형 급전구조를 갖고 U-slot을 추가하여 이중 공진 효과를 이용하였다. 설계된 안테나의 주파수 대역폭(VSWR 2:1)은 $797MHz\sim1013MHz$로 215MHz(23.8%)의 특성을 보였다. 또한 E-평면과 H-평면 모두 이득은 9.3dBi 이상, 3dB 빔폭은 $60^{\circ}$이상의 특성을 보였다.

  • PDF

L형 급전구조를 이용한 800MHz대 광대역 안테나 설계 (The design of 800MHz band Broadband Antenna using L-Shaped)

  • 김갑기
    • 한국정보통신학회논문지
    • /
    • 제10권6호
    • /
    • pp.998-1002
    • /
    • 2006
  • 본 논문에서는 마이크로스트립 안테나의 좁은 대역폭 문제를 개선하여 CDMA대역을 비롯한, GSM, TRS대역을 통합할 수 있는 800MHz대역 광대역 안테나를 설계하고자 한다. L형 급전구조를 갖고 U-slot을 추가하여 이중 공진효과를 이용하였다. 설계된 안테나의 주파수 대역폭(VSWR 2:1)은 $797MHz\sim1013MHz$로 215MHz(23.8%)의 특성을 보였다. 또한 E-평면과 H-평면 모두 이득은 9.3dBi 이상, 3dB 빔폭은 $60^{\circ}$이상의 특성을 보였다.

Free vibration and elastic analysis of shear-deformable non-symmetric thin-walled curved beams: A centroid-shear center formulation

  • Kim, Nam-Il;Kim, Moon-Young
    • Structural Engineering and Mechanics
    • /
    • 제21권1호
    • /
    • pp.19-33
    • /
    • 2005
  • An improved shear deformable thin-walled curved beam theory to overcome the drawback of currently available beam theories is newly proposed for the spatially coupled free vibration and elastic analysis. For this, the displacement field considering the shear deformation effects is presented by introducing displacement parameters defined at the centroid and shear center axes. Next the elastic strain and kinetic energies considering the shear effects due to the shear forces and the restrained warping torsion are rigorously derived. Then the equilibrium equations are consistently derived for curved beams with non-symmetric thin-walled sections. It should be noticed that this formulation can be easily reduced to the warping-free beam theory by simply putting the sectional properties associated with warping to zero for curved beams with L- or T-shaped sections. Finally in order to illustrate the validity and the accuracy of this study, finite element solutions using the isoparametric curved beam elements are presented and compared with those in available references and ABAQUS's shell elements.

현장모형실험을 통한 AER옹벽의 지주보의 역학적 효과 (Mechanical Effects of Back Supporting Beam of Assembled Earth Retaining Wall on Field Model Tests Results)

  • 김홍선;임종철;최중현;서민수
    • 대한토목학회논문집
    • /
    • 제37권2호
    • /
    • pp.343-355
    • /
    • 2017
  • AER옹벽은 사면안정에 적용하는 억지말뚝을 옹벽에 결합한 구조로서 새롭게 개발되었으며, 종래의 옹벽보다 안정성과 경제성이 크게 향상 되었다. AER옹벽에 적용된 억지말뚝은 지주보로 명명하고, 지주보에 의해 구조적인 안정성을 증가될 것으로 판단되어 현장모형실험과 3D 수치해석을 실시하였다. 현장실험의 결과, L형 옹벽에 비해 토압이 상당히 감소하는 것을 확인할 수 있으며, 3D 수치해석을 통해 일반적인 L형 옹벽과 AER옹벽을 비교한 결과 최소 29.85%의 수평변위억제효과를 확인하였다. 즉, AER옹벽의 지주보의 뛰어난 역학적 안정성을 통해 경제성을 높일 수 있을 것으로 판단된다.

Behavior and crack development of fiber-reinforced concrete spandrel beams under combined loading: an experimental study

  • Ibraheema, Omer Farouk;Abu Bakar, B.H.;Joharib, I.
    • Structural Engineering and Mechanics
    • /
    • 제54권1호
    • /
    • pp.1-17
    • /
    • 2015
  • An experimental investigation is conducted to examine the behavior and cracking of steel fiberre-inforced concrete spandrel L-shaped beams subjected to combined torsion, bending, and shear. The experimental program includes 12 medium-sized L-shaped spandrel beams organized into two groups, namely, specimens with longitudinal reinforcing bars, and specimens with bars and stirrups. All cases are examined with 0%, 1%, and 1.5% steel fiber volume fractions and tested under two different loading eccentricities. Test results indicate that the torque to shear ratio has a significant effect on the crack pattern developed in the beams. The strain on concrete surface follows the crack width value, and the addition of steel fibers reduces the strain. Fibrous concrete beams exhibited improved overall torsional performance compared with the corresponding non-fibrous control beams, particularly the beams tested under high eccentricity.

Thin- Walled Curved Beam Theory Based on Centroid-Shear Center Formulation

  • Kim Nam-Il;Kim Moon-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.589-604
    • /
    • 2005
  • To overcome the drawback of currently available curved beam theories having non-symmetric thin-walled cross sections, a curved beam theory based on centroid-shear center formulation is presented for the spatially coupled free vibration and elastic analysis. For this, the displacement field is expressed by introducing displacement parameters defined at the centroid and shear center axes, respectively. Next the elastic strain and kinetic energies considering the thickness-curvature effect and the rotary inertia of curved beam are rigorously derived by degenerating the energies of the elastic continuum to those of curved beam. And then the equilibrium equations and the boundary conditions are consistently derived for curved beams having non-symmetric thin-walled cross section. It is emphasized that for curved beams with L- or T-shaped sections, this thin-walled curved beam theory can be easily reduced to the solid beam theory by simply putting the sectional properties associated with warping to zero. In order to illustrate the validity and the accuracy of this study, FE solutions using the Hermitian curved beam elements are presented and compared with the results by previous research and ABAQUS's shell elements.

도심-전단중심 정식화를 이용한 개선된 곡선보이론 (Curved Beam Theory Based On Centroid-Shear Center Formulation)

  • 김남일;경용수;김문영
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.1033-1039
    • /
    • 2006
  • To overcome the drawback of currently available curved beam theories having non-symmetric thin-walled cross sections, a curved beam theory based on centroid-shear center formulation is presented for the spatially coupled free vibration and elastic analyses. For this, the elastic strain and kinetic energies considering the thickness-curvature effect and the rotary inertia of curved beam are derived by degenerating the energies of the elastic continuum to those of curved beam. And then the equilibrium equations and the boundary conditions are consistently derived for curved beams having non-symmetric thin-walled cross section. It is emphasized that for curved beams with L- or T-shaped sections, this thin-walled curved beam theory can be easily reduced to tl1e solid beam theory by simply putting the sectional properties associated with warping to zero. In order to illustrate the validity and the accuracy of this study, FE solutions using the Hermitian curved beam elements are presented and compared with the results by previous research and ABAQUS's shell elements.

  • PDF

Enhanced UV-Visible Absorbance Detection in Capillary Electrophoresis Using Modified T-Shaped Post-Column Flow Cell

  • Lim, Kwan-Seop;Kim, Su-Hyeon;Hahn, Jong-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권2호
    • /
    • pp.295-300
    • /
    • 2002
  • The construction of the T-shaped post-column flow cell has been changed to enhance the practicability as a UV-visible absorbance detector for capillary electrophoresis. In this new design, a rectangular cube-shaped inner structure is employed, which completely fits the outer rectangular tubing. This arrangement has greatly facilitated the fabrication of the T-cells. In addition, the volume for the auxiliary flow has been dramatically reduced down to 300 ${\mu}L$, and its volume flow rate is optimized at 4.2 ${\mu}L$/min. The short optical path length in the sheath flows (500 ${\mu}m$ on each side) minimizes background absorption, and thus enhances its performance in low-UV wavelengths. We have optimized the auxiliary flow rate at 50 ${\mu}m$/s, so that migration times are insensitive to the flow rate. This optimization has improved repeatabilities in migration times and peak heights. A double-beam detection scheme using a pair of photodiodes is employed to increase the signal-to-noise ratio.