• Title/Summary/Keyword: L-필터

Search Result 449, Processing Time 0.037 seconds

Convergence Analysis of Adaptive L-Filter (적응 L-필터의 수렴성 해석)

  • Kim, Soo-Yong;Bae, Sung-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1210-1216
    • /
    • 2009
  • In this paper we analyze the convergence behavior of the recursive least rank (RLR) L-filter. The RLR L-filter is an order statistics filter, filter coefficients of which are the weights according to the order of magnitude of inputs. And RLR L-filter is a non-linear adaptive filter, that uses RLR algorithm for coefficient updating. The RLR algorithm is a non-linear adaptive algorithm based on rank estimates in Robust statistics. The mean and mean-squared convergence behavior of the RLR L-filter is examined with variable step-sizes. The RLR L-filter adapts the median filter type to the heavy-tailed distribution function of impulse noise, and adapts the average filter type to Gaussian noises.

  • PDF

An Adaptive RLR L-Filter for Noise Reduction in Images (영상의 잡음 감소를 위한 적응 RLR L-필터)

  • Kim, Soo-Yang;Bae, Sung-Ha
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.1
    • /
    • pp.26-30
    • /
    • 2009
  • We propose an adaptive Recursive Least Rank(RLR) L-filter which uses an L-estimator in order statistics and is based on rank estimate in robust statistics. The proposed RLR L-filter is a non-linear adaptive filter using non-linear adaptive algorithm and adapts itself to optimal filter in the sense of least dispersion measure of errors with non-homogeneous step size. Therefore the filter may be suitable for applications when the transmission channel is nonlinear channels such as Gaussian noise or impulsive noise, or when the signal is non-stationary such as image signal.

  • PDF

The RMS Current Stress Reduction Technique in Link Capacitor of Two-stage AC/DC Converter (2단 AC/DC 컨버터의 링크 캐패시터 전류 스트레스 저감 기법)

  • Jang, Doo-Hee;Jung, Young-Jin;Roh, Chung-Wook;Hong, Sung-Soo;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.449-456
    • /
    • 2009
  • The RMS(Root Mean Square) current stress reduction technique for the PFC link capacitor is proposed. Although the various parameter is exist for optimizing the link capacitor, the RMS current stress is the most weighty practical parameter. The proposed C-L filter can reduce effectively the RMS current stress by filtering the output current. And with the C-L-L-C filter proposed in this paper, the more RMS current stress can be reduce because it filters not only the output current, like C-L filter, but also the input current of DC/DC stage. The proposed filter is simple to design and have no effect on the control part of the PFC because of the very low crossover frequency. To confirm the validity of proposed filter, theoretical analysis, the design guide, verification of experimental results are presented.

Analysis of Switching Harmonics Attenuation in Resonance Frequency Variation by Elements of LCL Filter (LCL 필터요소에 의한 공진주파수 변화에 따른 스위칭고조파 감쇄성능 분석)

  • Kim, Yong-Jung;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.157-158
    • /
    • 2016
  • LCL 필터는 스위칭 고조파를 저감하는 저역통과필터로써 L 필터에 비해 경제적이며 효과적인 스위칭고조파 감쇄능력을 갖는다. 하지만 LCL 필터는 L 필터에서 존재하지 않은 공진문제를 야기한다. 이러한 LCL 필터의 공진현상은 계통주입전류의 품질을 저하시키고 LCL 필터의 고조파 억제성능을 저하시킬 수 있는 잠재적 요소이다. 최근에는 스위칭 고조파 및 LCL 필터 공진성분 뿐만 아니라 기본파 주파수 부근의 저차 고조파 성분도 계통주입전류를 왜곡시키는 원인의 하나로 밝혀져다. 그러므로 LCL 필터를 설계하기 위해서는 주요 주파수 영역에서의 정확한 필터동작해석이 요구된다. 본 논문은 기본파 주파수, 공진주파수, 스위칭주파수에 대한 L 필터와 LCL 필터의 주파수응답을 통해 필터의 동작을 해석하며, 시뮬레이션을 통해 계통주입전류의 스위칭 고조파 및 저차 고조파를 저감하기 위한 최적의 필터인덕터 비율을 제안한다.

  • PDF

Experimental Study on the Effect of Filter Layers on Pumping Capacity and Well Efficiency in an Unconfined Aquifer (자유면대수층에서 필터층이 취수량 및 우물효율에 미치는 영향에 대한 실험적 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Choi, Yong-Soo;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.405-416
    • /
    • 2017
  • This study evaluated a model unconfined aquifer comprising a sand or gravel layer, a filter layer, a pumping well, and an observation well. The model was employed in step drawdown tests and then used to assess the permeability of each test tank. The optimal yield and well efficiency were then calculated. Evaluation of yield by step in sand layer filters of equal thickness gave optimized watering rates of 22.03 L/min in the double filter and 19.71 L/min in the single filter. The double filter's yield was 115.0% that of the single filter. A comparison of double and single filters, each 10 cm thick, showed the double filter to have a maximum yield of 182.7%. Yields for the gravel layer were 73.56 L/min for a double filter and 65.47 L/min for a single filter of the same thickness; the former value is 112.3% of that of the latter. Comparison of double and single filters with 10-cm-thick gravel layers revealed that the double filter had a maximum yield of 160.9%. Results for sand wells showed the double filter to have a maximum efficiency of 70.4% and the single filter to have a minimum efficiency of 37.1%. Gravel-layer well efficiencies were >66.5% for both double and single filters (each 30 cm thick), but only 22.5% for a 10-cm-thick single filter. This study confirms that permeability improved as the filter material became thicker; it also shows that a double filter has a higher yield and well efficiency than a single filter. These results can be applied to the practical design of wells.

A basic study on the filter to reduce harmornic current of grid connected single phase multi-level converter (계통 연계형 단상 멀티레벨 컨버터의 고조파 전류 저감을 위한 필터에 관한 연구)

  • Han, Sang-Hyup;Kim, Heung-Geun;Cha, Honnyong;Chun, Tae-Won;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.182-183
    • /
    • 2016
  • 계통 연계형 인버터에서는 고조파 전류를 저감하기 위하여 필터가 필요하다. 이러한 고조파 저감을 위하여 LCL 필터나 LCL 필터의 커패시터 단에 직렬로 L을 추가한 직렬 공진을 이용한 LLCL 필터가 있다. 이러한 필터들은 특정 주파수 대역의 고조파를 효과적으로 제거할 수 있으며 기존의 L 필터보다 용량이 줄어든다. 본 논문에서는 단상 멀티 레벨 컨버터의 PWM 주파수 성분의 고조파 저감 효과를 갖는 L, LLCL 필터를 설계하고 비교한다.

  • PDF

정지형 능동전력 필터

  • 최규하
    • 전기의세계
    • /
    • v.36 no.9
    • /
    • pp.673-682
    • /
    • 1987
  • 본고에서는 교류전원측에 발생하는 고조파를 제거하기 위한 정지형 능동전력필터에 관해 기술하였다. 능동필터는 기존의 L-C필터와는 달리 능동소자인 전류원을 사용하여 계통으로 직접 고조파보상전류를 주입합으로써 고조파를 상쇄시키는 장치이다. 이러한 정지형 필터가 갖는 특성을 요약하면 다음과 같다. 1. 정지형 필터는 한대만으로 다수대의 L-C 수동필터를 부착한 것과 같은 효과를 발휘한다. 2. 필터가 전류를 주입한 만큼 고조파를 제거시키게 되므로 과부하로 되는 일이 전혀 없다. 3. 능동필터내 전류형 인버터에 인가되는 신호를 조작해서 제거하는 고조파의 차수들과 양을 얼마든지 가변시킬 수 있다. 4. 정지형 필터는 수동필터의 경우처럼 주파수와 L및C의 변동에 따라 고조파 억제특성이 변하지 않는다. 이상과 같은 장점을 지니는 정지형 필터는 설비비의 면에서도 수동필터보다 불리하지는 않을 것이다. 더구나 저렴한 대용량의 반도체소자들이 지속적으로 개발될 것으로 미루어 다음 세대의 교류필터로서 각광받을 것이다. 그리고 현존하는 능동필터에 무효전력보상의 기능까지 추가시켜 하나의 장치로 구성시키는 문제는 금후 이루어져야 할 좋은 연구과제라고 사료된다.

  • PDF

Configuration of low-cost hybrid grid-connected filter (저가형 하이브리드 계통 연계 필터의 구성)

  • Kim, Jeong-Hun;Kim, Hyo-Seon;Wang, Zhi-ming;Chung, Dae-Won;Yang, Seung-Hak;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.76-77
    • /
    • 2013
  • 최근 풍력발전등의 분산전원 설치가 많아짐에 따라 계통연계 인터페이스 필터에 대한 연구가 활발히 진행되고 있다. 이러한 인터페이스 필터는 LCL 필터인 경우가 대다수인데 그 제작과 설치 비용이 만만치않음이 현실이다. 그 중 코어와 코일의 복합체인 인덕터의 설치에 노력과 비용이 가장 크게 들어간다고 볼 수 있다. 본 논문은 최근의 하이브리드 타입의 코어에 착안하여 인덕터 설계에 있어서 페라이트/더스트코어 혹은 하이브리드타입 코어를 인입쪽의 인덕터(L1)요소로 하고 계통 인출쪽 인덕터(L2)를 규소강판으로 하는 혼합형 LCL 필터를 제안한다. 인입쪽의 L1C필터는 LPF로 작동하므로 L2를 저주파수용 규소강판으로 설계하여 결과적으로 비용을 저감함이 본 논문의 초점이다. 그 효과는 선형 재질을 사용한 PSIM 시스템 시뮬레이터를 활용하여 검증한다.

  • PDF

The Clinical Effects of Leukocyte-Depleting Filter on Cardiopulmonary Bypass (체외순환 시 백혈구 제거필터 사용의 임상효과)

  • 박경택;최석철;최국렬;정석목;최강주
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.454-464
    • /
    • 2001
  • Background: It has been recognized that systemic inflammatory reaction and oxygen free radical formed by activated leukocyte in the procedure of cardiopulmonary bypass(CPB) frequently produce postoperative cardiac and pulmonary dysfunction. The purpose of this study was to evaluate the efficacy of leukocyte-depleting filters in the cardiopulmonary bypass circuit for patients undergoing open heart surgery(OHS). Material and method: The study involved 15 patients who underwent OHS with a Leukoguard-6 leukocyte filter placed in the arterial limbs of the bypass circuit(filter group, n=15) and 15 patients who did not have the filter(control group, n=15). We analyzed the differences between the groups in intraoperative changes of peripheral blood leukocyte and platelet counts, pre- and postbypass changes of malondialdehyde(MDA), troponin-T(TnT), 5'-nucleotidase(5'-NT) in coronary sinus blood, spontaneous recovery rate of heart beat after CPB, pre-and postoperative cardiac index(Cl) and pulmonary vascular resistance(PVR), and the amounts of postoperative bleeding and sternal wound complication. Result: During CPB, total leukocyte count of the filter group(9,567$\pm$ 842/㎣) was significantly less than that of the control group(13,573+1,167/㎣) (p<0.01), but there was no significant difference in platelet count between the groups. Postoperative levels of MDA(3.78+0.32 $\mu$mol/L vs 5.86+0.65 $\mu$mo1/L, p<0.01), TnT(0.40$\pm$0.04 ng/mL vs 0.59$\pm$0.08 ng/mL, p<0.05) and 5'-NT(3.88$\pm$0.61 U/L vs 5.80$\pm$0.90 U/L, p<0.05) were all significantly lower in the filter group than the control group. Postoperative Cl was higher in the filter group than the control group(3.26$\pm$0.18 L/$m^2$min vs 2.75$\pm$0.17 L/$m^2$/min, p=0.05). PVR of the filter group was lower than that of the control group(65.87$\pm$7.59 dyne/sec/cm$^{5}$ vs 110.80+12.22 dyne/sec/cm$^{5}$ , p<0.01). Spontaneous recovery rate of heart beat in the filter group was higher than that in the control group(12 patients vs 8 patients, p<0.05). Postoperative wound infection occurred in one case in the filter group and 4 case in the control group(p<0.05). Postoperative 24 hour blood loss of the filter group was more than that of the control group (614$\pm$107 mL vs 380+71 mL, p=0.05).

  • PDF

Active Power Filter with low DC link current ripple (낮은 직류단 전류 리플을 갖는 능동전력필터)

  • Hong, Seung-Pyo;Jung, Young-Gook;Oh, Seung-Yeol;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.23-24
    • /
    • 2012
  • 본 연구에서는 스너버로 동작하는 커패시터 C를 갖는 3상 능동전력필터의 직류측에 인덕터 L을 추가하여 직류단 전류의 리플을 감소시키는 방법을 제안하였다. 능동전력필터는 종전의 스너버 만을 이용하여 능동필터 기능을 수행하는 회로에 L을 추가하여 직류단 전류의 리플을 절반 정도 감소시켜 능동전력 필터의 소자에 스트레스가 줄어드는 것을 실험을 통하여 확인할 수 있었다.

  • PDF