• Title/Summary/Keyword: Korean environmental standard method

Search Result 1,296, Processing Time 0.026 seconds

A Study on the Pro-Environmental Energy Supply Program of Urban Enterprises on the concept of BAT(Best Available Technology): Application of Air Environmental Indices and Benefit-Cost Analysis Based (한 도시 사업체 에너지 수급의 최적화 방안 연구 - 대기오염지수와 경제성 평가를 중심으로 -)

  • Kwon, Yong-Sik;Kim, Yong-Bum;Chung, Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.89-102
    • /
    • 1998
  • The purpose of this study is to seek AEI(Air Environmental Indices), PSI(Pollutant Standard Index) and the urban air quality control goal(the best available alternative energy program) by assessing the best ratio of energy types used in urban enterprises, based on harmful health effect and air quality standard and costs. This study is focused on an urban area(Puchun), where area sourcees are associated with heavy traffic, large population, and its industrial sources with large emissions. In the first step, air modeling, estimation of AEI and PSI, and benefit-cost analysis were carried out. In the second step, we assessed that 660 scenarios about the ratio of B-C oil, light oil and LNG used in urban enterprises with regard to air quality and cost. In the third step, the best available alternative energy program was selected for the ratio of energy species(B-C oil, light oil and LNG) by using the lexicographic method. From the emission analysis, main source of $NO_2$ is identified as industries and air quality is evaluated according to the ratio of B-C oil, light oil and LNG used in urban enterprise. The modeling data of TSP, $SO_2$, $NO_2$, CO, $O_3$, by ISC3 and PBM are respectively $118{\mu}g/m^3$, 0.027ppm, 0.025ppm, 2.0ppm, 0.55ppm in indurstrial area. That data are close to Environmental Air Quality Standard. By means of sensitivity analysis, we obtained the difference in concentration between the areas(Nae-dong, Joong-dong) according to the ratio of B-C oil, light oil and LNG used in the industries. From the result of alternatives assessment the lowest AEI value and cost, the ratio of B-C oil, light oil and LNG are 2.5%, 20%, 77.5%, respectively.

  • PDF

A Study on the Comparison of Measuring Methods and Development of Emssion Factor on Mercury from Large-Scale Emission Sources (대형배출원에서의 수은 측정방법 비교 및 배출계수 개발에 관한 연구)

  • Kim, Hyung-Chun;Kim, Rhok-Ho;Kim, Jong-Hyeon;Lim, Seung-young;Kang, Dae-Il;Hong, Ji-Hyung;Jang, Kee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.184-192
    • /
    • 2016
  • Recently, studies on reducing mercury have been actively conducted worldwide, which include the current status of mercury emissions and mercury control technology. Among the control technology, Sorbent Trap measurement method has been aggressively developed due to its reliability, easiness in measurement and analysis. The purpose of this study is to evaluate the applicability of the new international measurement method; Sorbent Trap. For this, the study compared the Sorbent trap method (US EPA Method 30B) and the Korean Standard Method for Examination of Air (ES 01408.1) to evaluate their reliability, and developed mercury emission factors. As the result, the relative standard deviations (% RSD) of the two methods were 3.5~13.4% at Coal-fired Power Plants (CPP), 4.0~18.4% at Cement Kilns (CK), and 3.0~11.3% at Medical Waste Incinerators (MWI). The emissions factors were developed as 14.50 kg/ton at CPP, 45.10 kg/ton at CK, and 1,290.2 kg/ton at MWI.

Optimization of Distribution Basin Weirs at a Sewage Treatment Plant Based on Computational Fluid Analysis Using the Taguchi and Minitab Method (전산유체해석과 다구찌 및 미니탭 방법을 활용한 하수처리장 분배조 웨어 최적화)

  • Jung, Yong-Jun;Park, Hae-Sik;Cho, Young-Man
    • Journal of Environmental Science International
    • /
    • v.30 no.12
    • /
    • pp.983-991
    • /
    • 2021
  • The role of the distribution basin role is to apportion incoming raw water to the primary sedimentation basin as part of the water treatment process. The purpose of this study was to calculate the amount of water in the distribution basin using computational fluid dynamics (CFD) analysis and to find a way to improve any non-uniformity. We used the Taguchi method and the minitab tool as optimization methods. The results of the CFD calculation showed that the distribution flow had a deviation of 5% at the minimum inflow, 10% at the average inflow, and 22% at the maximum inflow. At maximum flow, the appropriate heights of the 7 weirs(C, D, A, B, E, F, G) were 40 mm, 20 mm, 20 mm, 0, 0, 0, and 20 mm, respectively, according to the Taguchi optimization tool. Here, the maximum deviation of the distribution amount was 9% and the standard deviation was 23.7. The appropriate heights of the 7 weirs, according to the Minitab tool, were 40 mm, 20 mm, 20 mm, 0, 0, 0, and 20 mm, respectively, for weirs C, D, A, B, E, F, and G. Therefore, the maximum deviation of the distribution amount was 8% and the standard deviation was 17.1, which was slightly improved compared to the Taguchi method.

Improvement and Application for Environmental Conservation Value Assessment Map(ECVAM) of Nationwide Land in Korea

  • Lee, Moung-Jin;Jeon, Seong-Woo;Jo, Min-Jeong;Song, Won-Kyong;Kang, Byung-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.5
    • /
    • pp.335-346
    • /
    • 2007
  • This study is aiming at improving the Environmental Conservation Value Assessment Map(ECVAM) of National Land in Korea. The ECVAM items are composed of legal and environmental/ecological assessments. A popular method applied to ECVAM is an overlay environmental/ecological assessment items. The purpose of this study is to offer complementary items of the ECVAM by examining assessment items. In this study we assessed the ECVAM by five methods. Method 1 is Grade 1 areas of each administrative district; Method 2 is comparing overlapped areas of each assessment items Grade 1, 2 and permission of each assessment items duplication; Method 3 is Grade 1, 2 areas by only singular assessment items; Method 4 is Grade 1 areas only of Method 2; and Method 5 is Grade 2 areas only of Method 2. Method 1 showed Seoul and other metropolitan cities revealed a large proportion of Grade I regions by the legal assessment items. Gang won-Do, showed a large proportion of Grade I regions by the environmental/ecological assessment item. Method 2 showed 93.4% of diameter Grade II(standard for stability); forest diameter item accounted for 99.9% by Method 3, Method 4 showed 95.7% of forest diameter, and forest density accounted for 66.4% by Method 5. This study contributes to reduce the complexity in the process of manufacturing ECVAM of National Land, and to raise the flexibility in the process of managing and updating this map.

Comparison of Formaldehyde Emission of Wood-based Panels with Different Adhesive-hardener Combinations by Gas Chromatography and Standard Methods

  • Eom, Young Geun;Kim, Sumin;Baek, In-Chan;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.2 s.130
    • /
    • pp.29-39
    • /
    • 2005
  • Formaldehyde emissions from wood-based panels bonded with pine and wattle tannin-based adhesives, urea-formaldehyde resin (UF), melamine-formaldehyde resin (MF), and co-polycondensed resin of urea-melamine-formaldehyde (UMF) were measured by the Japanese standard method using a desiccator (JIS A 1460) and the EN 120 (European Committee For Standardization, 1991) method using the perforator value. In formaldehyde emission, all particleboards made using the wattle tannin-based adhesive with three different hardeners, paraformaldehyde, hexamethylenetetramine, and tris(hydroxyl)nitromethan (TN), satisfied the requirements of grade $E_1$. But only those made using the pine tannin-based adhesive with the hexamine as hardener met the grade $E_1$ requirements. Hexamine was effective in reducing formaldehyde emission in tannin-based adhesives when used as the hardener. While the UF resin showed a desiccator value of $7.1mg/{\ell}$ and a perforator value of 12.1 mg/100 g, the MF resin exhibited a desiccator value of $0.6mg/{\ell}$ and a perforator value of 2.9 mg/100 g. According to the Japanese Industrial Standard and the European Standard, the formaldehyde emission level of the MDF panels made with UF resin in this study came under grade $E_2$. The formaldehyde emission level was dramatically reduced by the addition of MF resin. The desiccator and perforator methods produced proportionally equivalent results. Gas chromatography, a more sensitive and advanced method, was also used. The samples for gas chromatography were gathered during the experiment involving the perforator method. The formaldehyde contents measured by gas chromatography were directly proportional to the perforator values.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

A Study on the Conversion of Annoyance using the Noise Standard in Korea (국내 소음기준을 이용한 성가심(annoyance) 변환에 관한 연구)

  • Kim, Deuk-Sung;Chang, Seo-Il;Lee, Ki-Jung;Lee, Yeon-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.754-758
    • /
    • 2006
  • The purpose of this study is to propose calculation and application method of a common factor from different noise source unit such as $L_{eq}$ and WECPNL, A calculation was conducted by method that propose TNO-PG. Also, An applied example is a noise environmental standard of Korea and Japan. After %HA of two country are calculated, noise standards of two countries were compared by using %HA. The result by a equation of %HA is to convert a noise level($L_{dn}$) into a %HA. To calculate a %HA, First $L_{eq}$ is converted into $L_{dn}$. Then, $L_{dn}$, has inputted into and %HA has deduced from a %HA equation of TNO-PG. If the same area is applied the same %HA value according to area categories, it can be applied the same %HA to different noise sources. As a results. a noise levels have computed different values because responses of human change in accordance with a noise sources. This results can be applied to the noise environmental assessment for a domestic railway and aircraft noise.

  • PDF

Determination of Physical Chemical Properties of Organic and Inorganic Substrates for Horticulture by European Standard Method (유럽표준배지분석법에 의한 원예용 유기·무기성 배지의 물리화학적 특성)

  • Kang, Ji-Young;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.3
    • /
    • pp.143-148
    • /
    • 2004
  • Organic and inorganic substrates commonly used in Korea include peat moss, coir, bark, rice hull, saw dust, perlite, vermiculite, rockwool granulate, clay ball, and so on. The objective of this study was to get analytical results about the physical and chemical properties of these substrates by European standard methods. Organic substrates showed different properties depending on the type, origin and manufacturing processes. Inorganic substrates showed different properties depending on the type and particle size. Further study on physical and chemical properties for more raw materials and commercially available growing media analyzed by European standard method and comparison of the results with those by Korean standard method is needed.

A Study on the Mercury Emission Characteristic and Comparison Tests for Applicability of Latest Mercury Measuring Methods - Focus on the Cement Kiln - (시멘트 소성시설에서의 수은 배출특성 및 최신 측정방법 적용성 평가 연구)

  • Kim, Hyung-Chun;Kim, Hee-Jin;Kim, Jong-Hyeon;Kang, Dea-Il;Park, Jung-Min;Kim, Jeong-Hun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.3
    • /
    • pp.241-250
    • /
    • 2017
  • Recently, there has been growing interest in the emission characteristics and behavior of anthropogenic mercury compounds from emission sources. It is required to establish a standard for reliable mercury measurement method. Therefore, this study has evaluated the applicability of the new measurement method; Continuous Emission Monitoring (US EPA 30A, CEM). In addition, the reliability evaluation was conducted through Ontario Hydro Method (ASTM D6784, OHM) and Sorbent trap method (US EPA Method 30B). As a monitoring result for three months via CEM from cement kiln, the maximum mercury compounds concentration was about $600{\mu}g/Sm^3$. This is because of the various of raw materials and fuel, and the absence of mercury-control device. The mercury compounds concentrations of OHM, Sorbent trap and CEM were 13.64 $(3.33{\sim}32.41){\mu}g/Sm^3$, $13.94(5.97{\sim}23.44){\mu}g/Sm^3$ and $14.68(6.19{\sim}26.75){\mu}g/Sm^3$, respectively. The relative standard deviations (% RSD) of the three methods were 5.1~40.9%. The result of this study suggest that it is possible to apply the CEM in the cement kiln when, QA/QC such as calibration is verified.

Implementation of PXIe platform based portable Automatic Test Equipment to improve reliability

  • Gwon, Hyeok-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.9-16
    • /
    • 2017
  • In this paper, we propose a development method of portable Automatic Test Equipment based on PXIe platform. Legacy VME form factor structured test equipment has limited reuse and expansion of modules due to unapplied bus specification. In particular, these limitations can cause development periods and costs to increase, and the reliability of environmental conditions is lacking due to non-standard modules. The test equipment of the proposed PXIe platform can use diverse COTS modules to shorten the development period and minimize the instability between developments. The PXIe development module works with standard Xilinx FPGAs, PXIe Windows device drivers, and applications on standard PXIe buses. The use of standard bus and COTS modules increases scalability and reusability, enabling rapid development and excellent maintenance. Through the test, we show the proposed test equipments can be implemented efficiently between the development processes and proved their reliability through function tests and environmental tests.