• Title/Summary/Keyword: Korean dual system

Search Result 1,904, Processing Time 0.033 seconds

Optimal Tuning of Nonlinear Parameters of a Dual-Input Power System Stabilizer Based on Analysis of Trajectory Sensitivities (궤도민감도 분석에 기반하여 복입력 전력시스템 안정화 장치(Dual-Input PSS)의 비선형 파라미터 최적화 기법)

  • Baek, Seung-Mook;Park, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.915-923
    • /
    • 2008
  • This paper focuses on optimal tuning of nonlinear parameters of a dual-input power system stabilizer(dual-input PSS), which can improve the system damping performance immediately following a large disturbance. Until recently, various PSS models have developed to bring stability and reliability to power systems, and some of these models are used in industry applications. However, due to non-smooth nonlinearities from the interaction between linear parameters(gains and time constants of linear controllers) and nonlinear parameters(saturation output limits), the output limit parameters cannot be determined by the conventional tuning methods based on linear analysis. Only ad hoc tuning procedures('trial and error' approach) have been used. Therefore, the steepest descent method is applied to implement the optimal tuning of the nonlinear parameters of the dual-input PSS. The gradient required in this optimization technique can be computed from trajectory sensitivities in hybrid system modeling with the differential-algebraic-impulsive-switched(DAIS) structure. The optimal output limits of the dual-input PSS are evaluated by time-domain simulation in both a single machine infinite bus(SMIB) system and a multi-machine power system in comparison with those of a single-input PSS.

A Study on Korean Dual System: K-Dual System (한국형 듀얼 시스템(K-Dual 시스템)의 구축 및 운영방안에 관한 연구)

  • Lee, Moon-Su;Lee, Woo-Young;Oh, Chang-Heon
    • Journal of Practical Engineering Education
    • /
    • v.5 no.2
    • /
    • pp.139-149
    • /
    • 2013
  • In this paper, we proposed a new Korean Dual system, K-Dual System, and discussed the concepts and details about three sub-models of the system, IPP, W3 and corporate university models. Propose K-Dual system is a new and unique educational model that combines academic study and industrial work in order to solve the various problems of existing work-study parallel educational systems in Korea. K-Dual System has two tracks, Academic and Vocational tracks. Academic track has a long-term field experience training program, IPP program. On the other hands, Vocational track can be divided into two sub-models and those are $W^3$ and corporate university. Finally, we summarized several key points for the successful setup and operation of K-Dual system.

Implementation of Dual Cycle in Container Yard based on Ad-hoc Networks (Ad-hoc 네트워크 기반의 컨테이너장치장의 Dual Cycle 구현)

  • Park, Doo-Jin
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.4
    • /
    • pp.998-1007
    • /
    • 2013
  • At container terminals, a major measurement of productivity can be work efficiency. For improving the productivity of container crane, the more efficient container yard operation method is necessary in container terminals. Recently, container terminal operators make an experiment on the dual cycle operation, which ship loading/unloading were carried out simultaneously, for increasing the productivity of container crane. In this paper, propose a system operating efficient dual cycle methods as utilize Ad-hoc technology in distributed port operation system. The dual cycle methods that proposed recognizes position information of Y/T during an action in Ad-hoc networks in case of container transfer works by real time as load an Ad-hoc module to Y/T taking charge of a container transfer with quay and yard. Utilize Ad-hoc networks technology in an operating system of container yard, and efficiently distributed processing done Y/T to container crane compare with operation systems of the existing dedicated method, and an improvement can do an operating system of an yard.

A Study on the Implementation of a Control System with Dual Structure and Its Reliability Analysis (이중구조를 갖는 제어시스템의 구현과 신뢰도 분석에 관한 연구)

  • ;;;Zeung Nam Bien
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1351-1363
    • /
    • 1990
  • In this paper, a reliable control system structured with dual CPU modules and dual I/O modules is implemented as a means of achieving a highly reliable fault tolerant control system. For this, faults in the system modules are first examined, and a fault detection technique consisting of self diagnostic, comparison process, and exception processing is applied. Self diagnostic is used to locate which components in the modules have been failed, while comparison process is to cmpare control outputs computed by both CPU modules and protect the plant from malfunction by blocking failed control outputsin advance. Finally exception processing is used to determine the faults that are not detected immediately by the self diagnostic and comparison process, e.g. bus error processing when acknowledge signal for data transfer is not activeted in the I/O modules. Also reliability analysis is conducted for the discrete time Markov model with dual structure. It is shown quantitatively that the reliability is improved in the control system with dual structure in comparison with a system with single module structure.

  • PDF

Performance analysis of dual source heat pump system with single unit dual source evaporator (SUDS증발기를 사용한 2중열원 열펌프의 성능해석)

  • 우정선;이세균;이재효;박효순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF

Analysis of Organizational Performance of Employees of the Work-Learning Dual System Training Center (일학습병행 공동훈련센터 전담인력 조직성과 진단 및 분석 )

  • Tae-Seong Kim;Jun-Ki Min
    • Journal of Practical Engineering Education
    • /
    • v.15 no.1
    • /
    • pp.199-208
    • /
    • 2023
  • Performance analysis for work-learning dual system has been mainly conducted from the perspective of diagnosing the effectiveness of policies at the macro level. This study aims to analyze issues in organizational management of the work-learning dual system training center by conducting an analysis focusing on the organizational performance of the work-learning dual system training center's employees. As a result of the analysis, it was confirmed that the perception and attitude of employees toward the work-learning dual training center differed depending on the type of work-learning dual system and the type of employment contract. Among the types of work-learning dual system, overall, in the case of IPP, the organizational performance of employees was low, while the apprenticeship was relatively high. As for the type of employment contract, the need for institutional improvement has been derived, especially for the project contract workers.

Operation Analysis and New Current Control of Parallel Connected Dual Converter System without Interphase Reactors (상간리액터 없는 병렬연결 듀얼컨버터 시스템의 동작해석과 새로운 전류제어)

  • Ji, Jun-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.7
    • /
    • pp.488-493
    • /
    • 2000
  • In this paper, a predictive current control of 12-pulse parallel connected dual converter system without interphase reactors(IPR) is presented. Firstly, the characteristics of system without IPR are analyzed and compared with that of system with IPR. And the predictive current control of this system is discussed. Finally the validity of the presented system and the excellence of the predictive current control response is proved through the simulation results and experimental results.

  • PDF

Production of inulooligosaccharides from inulin by a dual endoinulinase system

  • Jo, Yeon-Jeong;Sinha, Jayanta;Park, Jong-Pil;Yun, Jong-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.587-589
    • /
    • 2000
  • The production of inulooligosaccharides from inulin by a dual endoinulinase system of Pseudomonas sp and Xanthomonas sp. was investigated the optimum conditions for a dual endoinulinase reaction were as follows : pH,5.8; temperature, $50^{\circ}C$; substrate concentration, 50 g/l; enzyme ratio, 3:1 as Xanthomonas endoinulinase to Pseudomonas endoinulinase. Under optimum conditions, the maximum yield of oligosaccharides was 90.5% in total sugar basis by dual endoinulinase system

  • PDF

Double-Pitch Dual Grating Method for Detecting the Axial Offset in Roll System (2 배수 피치비를 갖는 이중 격자 측정법을 이용한 축방향 롤 회전 오차 측정)

  • Kim, Geehong;Ten, Aleksey-Desen;Lim, Hyungjun;Lee, Jaejong;Choi, Keebong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.12
    • /
    • pp.1273-1279
    • /
    • 2013
  • We propose a dual grating alignment technique for roll-to-roll positioning which allows achieving nanometer scale alignment by using micro-size marks. The high precision alignment system were designed and manufactured. It was confirmed that the optical system was properly adjusted and fully aligned with the dual gratings. The experiment and computer simulation results were presented. Alignment accuracy below 50 nm was achieved.

A Study on the Effects of Dual Dynamic Vibration Absorber for Damped Vibration System (감쇠진동계에 부착된 복합동흡진기의 효과에 관한 연구)

  • 안찬우;최석창;김동영
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.1039-1048
    • /
    • 1997
  • This paper describes the effects of dual dynamic vibration absorbers attached to a primary vibration system with damping. The efficiency of dual dynamic vibration absorbers was investigated with the height of amplitude ratio at the resonance frequency ratio of the damped vibration system according to mass ratio, natural frequency ratio and damping ratio. The variation of amplitude ratio related to frequency ratio of primary vibration system is verified experimentally and theoretically according to dual dynamic vibration systems using computer program designed to find mutual relationship between two absorbers.

  • PDF