• Title/Summary/Keyword: Korean Standard

Search Result 34,688, Processing Time 0.061 seconds

Establishment of National Standard System for 20.000 A Current Transformer (20,000 A 전류변성기 국가표준 시스템 구축)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jean-Hong;Kim, Myung-Soo;Kim, Yoon-Hyoung;Han, Sang-Gil;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.6-13
    • /
    • 2008
  • National standard system for calibrating current transformer(CT) up to primary current of 20,000A have been established. The system consists of 20,000 A AC high current source, CT comparator, standard CT, CT under test and CT burden. An AC high current is applied tn the primary windings of both the standard CT and the CT under test, and then the CT comparator measures the ratio error and the phase displacement by comparing the secondary currents of the two transformers. As a validity check for 20,000 A CT calibration system, the comparison with the two national standard institutes(NMIs) has been performed using same CTs. The comparison results of the CTs are consistent with those measured at two NMIs within 0.004 % for ratio error and 0.1 min for phase displacement in the primary current ranges of Ip = 10 - 20,000 A with a secondary current of Is = 5 A.

A Case Study of Status and Characteristics of the BIM Standard in China (중국 BIM 표준의 현황과 특성에 관한 사례 분석)

  • Shin, Kyoo-Chul
    • Journal of KIBIM
    • /
    • v.8 no.3
    • /
    • pp.20-30
    • /
    • 2018
  • The Standard for BIM in Construction of China was released in 2017. The Unified Standard for BIM of China also took effects on 2017. The BIM standards of China needs to be compared with those related guidelines of Korea to find the status and characteristics for future development of BIM application in both countries' construction industries. The research methodology is a case study of comparing various standards of both countries. The case study results reveals many interesting issues for future BIM application and guidelines for practice of design and construction process. The research foundings include followings : LOD (Level of development) are well defined including LOD 350 in Chinese Standard. P-BIM(Practice based BIM) concepts and series of standards are set for the well-defined design and construction process by work stage in China. Korean standards shows more processes of design and documentation in detail. Major three aspects, particularity in BIM standard by work trade, practicality in BIM work process of design and construction, and professionality in subjects of BIM application, are analyzed and compared with various Guidelines of BIM in both countries.

A Study on the Evaluation of the Pipe Fracture Characteristic (실배관 파괴특성 평가에 관한 연구)

  • Park Jae-Sil;Kim Young-Jin;Seok Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.107-114
    • /
    • 2005
  • In order to analyze the elastic-plastic fracture behavior of a structure, the fracture resistance curve of the material should be known first. The standard CT specimen was used to obtain the fracture resistance curves of a piping system. However, it is known that the fracture resistance curve by the standard CT specimen is very conservative to evaluate the integrity of a structure. Also the fracture resistance curve is effected by the specimen geometry and the dimensions because of the constraint effect. The objective of this paper is to be certain the conservativeness of the fracture resistance curve by the standard CT specimen and to provide an additional safety margin. For these, the fracture tests using a real pipe specimen and the standard CT specimen test were performed. A 4-point bending jig was manufactured for the pipe test and the direct current potential drop method was used to measure the crack extension and the length for the pipe test. Also finite element analyses were performed with a CT specimen and a pipe in order to prove the additional safety margin. From the result of tests and analyses of the pipe and the standard CT specimen, it was observed that the fracture analysis with the standard CT specimen is conservative and the additional safety margin was proved.

A Structural Equation Model on Standard Precautions Compliance of Nursing Students (간호대학생의 표준주의 수행 구조모형)

  • Ha, Hey Jin;Kim, Eun A
    • Research in Community and Public Health Nursing
    • /
    • v.33 no.3
    • /
    • pp.321-331
    • /
    • 2022
  • Purpose: This study is to establish a structural model for standard precautions compliance of nursing students. This conceptual model was based on the IMB (Information-Motivation-Behavioral skills) model of Fisher and Fisher. Methods: Data were collected from October 12 to December 1, 2020, and the subjects were nursing students from G metropolitan city and J province, and the data of a total of 334 subjects were analyzed. For data analysis, this study used the SPSS 24.0 and AMOS 24.0 programs. Results: The hypothetical model showed a good fit to the data: 𝑥2=106.46 (p<.001), 𝑥2/df=2.54, RMSEA=.07, SRMR=.04, CFI=.96, TLI=.94. It was confirmed that the variables that have a statistically significant influence on the standard precautions compliance in nursing students were in the order of self-efficacy, social support, personal attitude, and standard precautions knowledge. The model explained 48.3% of the variance in standard precautions compliance of nursing students. Conclusion: It is necessary to develop and apply various specialized extracurricular programs that can induce an individual attitude toward observing standard precautions compliance in a positive direction in relationships with teachers and peers and gain their support.

Study to evaluate the correlation between structural core strength and strength development of standard cured specimens in a summer environment (하절기 환경에서 구조체 코어 강도와 표준양생 공시체 강도의 압축강도 발현 상관성 평가 연구)

  • Jeong, Min-Gu;Kim, Han-Sol;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.143-144
    • /
    • 2023
  • The compressive strength of concrete varies depending on various factors. Among them, based on the curing temperature, the KCS 14 20 10 Standard Specification for General Concrete calculates the nominal strength by applying the temperature correction value (Tn) based on the compressive strength of the standard cured concrete at 20±2℃ when designing the formulation strength. However, Tn is a correction value that considers only the temperature, and the correction of strength difference due to heat of hydration is not applied. Therefore, in this study, one-component and two-component concrete are mixed in the summer, structural concrete are manufactured, standard concrete specimen are manufactured, and coring is performed on the central and boundary parts of the structural concrete to calculate the correction value applied to the nominal strength by comparing the compressive strength of standard cured concrete on the 28th day of curing and the compressive strength of structural concrete on the 91st day of curing.

  • PDF

Assessment of Appropriateness of Standard for Insurance Coverage on Chemotherapy used in Non-small Cell Lung Cancer (NSCLC) (비소세포폐암에 사용되는 항암화학요법의 요양급여기준 적절성 평가)

  • Kim, Jeong-Yeon;Park, Eun-Ji;Bae, Min-Kyung;Yoon, Jeong-Hyun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.21 no.3
    • /
    • pp.193-207
    • /
    • 2011
  • Purpose: The purpose of this study is to assess appropriateness of current standard for insurance coverage by Health Insurance Review & Assessment Service (HIRA) on chemotherapy used in the treatment of advanced non-small cell lung cancer (NSCLC), by reviewing a variety of clinical evidences, and thereby, if needed, to propose an updated evidence-based recommendations. Methods: We collected data from HIRA regarding on the insurance standard which includes the scope and conditions for coverage on systemic chemotherapy of NSCLC. We performed a search for clinical databases and examined the most current clinical evidence from clinical literature including various clinical practice guidelines. Based on the collected data the appropriateness of HIRA standard for insurance coverage of chemotherapy of NSCLC was assessed. Results: Collected data demonstrated that HIRA standard did not reflect the most current clinical practice and evidence. Some were inappropriately listed in HIRA formulary and accepted as a chemotherapy being covered by insurance, despite the lack of evidences of clinical efficacy or superiority over other chemotherapeutic agents or regimens. In addition, there seems to be a need for a modification on the standard for insurance coverage of certain newer chemotherapeutic agents based on the current accumulated data showing their clinical efficacy and benefits in the selected group of NSCLC patients. Therefore, we concluded that current HIRA standard for insurance coverage on chemotherapy of NSCLC needs to be revised and we proposed an updated recommendation based on these latest clinical evidences. Conclusion: The standard for insurance coverage of chemotherapy should be continually examined its appropriateness based on the most recent clinical evidences in a timely manner so as to provide the most effective and safe therapy to cancer patients.

Histological study of the primo vascular system on the falciform ligament (Falciform ligament(간겸상인대)에서 관찰되는 프리모 조직의 조직학적 특성 연구)

  • Yeon, Sun-Hee;Kwon, O-Sang;Lee, Sae-Bhom;Cho, Seong-Jin;Choi, Kwang-Ho;Lee, Sang-Hun;Choi, Sun-Mi;Ryu, Yeon-Hee
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.2
    • /
    • pp.131-137
    • /
    • 2012
  • Objectives : Primo vascular system is known to new circulatory system and suggested as a anatomical structure of meridian system. Primo-vessels are present throughout the whole body. The purpose of this study is to identify primo tissues taken from falciform ligament and to compare with organ surface primo tissue, blood vessel and lymph vessel. Methods : Male Sprague-Dawley rats (8weeks old, 250~320g) used for this study. The medial line of the abdomen was dissected and searched for primo tissues in falciform ligament and on the internal organs using stereomicroscope. We performed serial cross section and histological investigations. The tissues were stained with hematoxylin-eosin and Masson's trichrome. Results : 1. The primo tissues attached on the falciform ligament had white color and length of 5~8mm. 2. We could observe primo tissues are classified with ligament tissues. 3. Histologically, primo tissue on falciform ligament and organ surface primo tissue could be considered same tissue. Conclusions : In this study, we observed primo tissue discovered on the falciform ligament. And we also histologically compared such discovered primo tissue with organ surface primo tissue. Consequently, we could consider that two tissues have histological similarity and possibility of connection in one network system.

A Study on the Comparison and Characteristics of Public Standard Housing Unit Plan before and after the Independence from the Japan Occupation (광복전후(光復前後) 공영주택(公營住宅)의 평면비교(平面比較)와 변화특성(變化特性)에 관한 연구(硏究))

  • Yoo, Jae-Woo
    • Journal of architectural history
    • /
    • v.11 no.2 s.30
    • /
    • pp.23-35
    • /
    • 2002
  • Even though there have been greate changes in the types and contents of the housing plan in Korea since the Modem age, it seems that the identity of traditional dwelling culture is still remains within it. The purpose of this study is to examine the characteristics and features in the development of the 'Public Standard' Housing Unit Plan by comparing the differences and similarities in unit plans in housings built on Japanese occupation period and those built after the period. From the study, we can conclude as follows: 1. The public standard housing unit plans on both periods have shown the common features in the composition of their physical forms in the way that the front-row area still remains the traditional housing culture and the rear-row area reflects the desires of the modem lives. The structure of the dual-row unit plan appeared in the public standard housing plan was caused by the cultural acculturation in Japanese occupation period. 2. The public standard housing unit plans, however, show the differences in the contents and meaning in units plans with the them of the Japanese housing because of the cultural differences. These differences took placed autonomously through the change of housing plans in the modern time, and have the common features such that 1) the changes in the Maru-centered plan type differ in composition from the inner-corridor plan type used Japanese housing, and 2) the composition of the open-inner spaces in the double-row housing plan reflects the single-row outer open space In the traditional housing. All of these cultural progresses in the public standard housing unit plans was took place as the result of the inner-oriented and notional circulations derived from the modernity. However, the transformed unit plans still contains the identity derived from the variation of the traditional Korean building elements such as Maru and Ondol. In other words, those are the Maru-centered and composed housing plans with juxtaposition of the inner block and the outer block. As the conclusion, though the public standard dwelling unit plan has the similarity in the physical form, it is different in the cultural Identity and meaning from the public standard plans before the independence from the Japan occupation.

  • PDF

A Working Standard Technique far Determination of Interference Correction Factors and Preparation of Standard Materials for CHIME Dating (CHIME 연대 측정의 간섭 보정 계수 결정과 표준 물질의 준비를 위한 실험실 표준법)

  • Cho, Deung-Lyong;Kato, Takenori;Suzuki, Kazuhiro
    • Journal of the Korean earth science society
    • /
    • v.27 no.5
    • /
    • pp.521-527
    • /
    • 2006
  • The EPMA analysis for CHIME dating requires standard materials, which include nuclear fuel materials that are rare and sensitive to handle. Any laboratory that does not meet these standards has had difficulties adopting the CHIME dating method. We have developed a working standard technique for CHIME dating to prepare standard materials without use of nuclear fuel materials. Mineral samples, such as small pieces of monazite that are homogeneous in X-ray intensities, are calibrated using well-characterized primary standards in one laboratory. Once this procedure is done, they can be readily usable as working standards in the other laboratories, only with measurement of X-ray intensities. This method is applicable in preparing standard materials for both chemical compositions and determination of X-ray interference correction factors, and it is independent from chemical composition of mineral standard.

A Study on Standard for State Assessment of Tunnel Structures (터널 구조물의 상태평가 기준에 관한 연구)

  • Oh, Hyuk-Hee;Shin, Yung-Suk;Lee, Jong-Woo;Park, Nam-Seo;Kim, Young-Geun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.4
    • /
    • pp.35-55
    • /
    • 2001
  • Recently, as tunnel structures are getting older and decrepit, many tunnel inspections are carried out for evaluating the tunnel state and safety. But, because there is no exact standard for tunnel state and safety, depending on subjective decision, the new standard to assess the tunnel state is required. The existing standard including mainly the assessment of the state of tunnel lining is not considered the characteristics of tunnel as underground structures. Also, the item of assessment and process of grading and classifying the state of tunnel is not objective and systemetic. In this study, new standard for assessment of tunnel state is presented for improving the problems in evaluating the tunnel state and safety. In the new standard, the new items of assessment including geotechnical condition were selected and graded, the process in classifying the tunnel state is quantitative for objective assessment for tunnel state. This new standard and method is practically used in effective safety inspection and diagnosis and tunnel maintenance.

  • PDF