• Title/Summary/Keyword: Korean Hearing in Noise Test

Search Result 68, Processing Time 0.026 seconds

Construction of Sound Quality Index for the Vehicle HVAC System Using Regression Model and Neural Network Model (회귀모형과 신경망모형을 이용한 차량공조시스템의 음질 인덱스 구축)

  • Park, Sang-Gil;Lee, Hae-Jin;Sim, Hyun-Jin;Lee, Jung-Youn;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1443-1448
    • /
    • 2006
  • The reduction of the vehicle interior noise has been the main interest of NVH engineers. The driver's perception on the vehicle noise is affected largely by psychoacoustic characteristic of the noise as well as the SPL. In particular, the HVAC sound among the vehicle interior noise has been reflected sensitively in the side of psychology. Even though the HVAC noise is not louder than overall noise level, it clearly affects subjective perception in the way of making a diver become nervous or annoyed. Therefore, these days a vehicle engineer takes aim at developing sound quality as well as reduction of noise. In this paper, we acquired noises in the HVAC from many vehicles. Through the objective and subjective sound quality evaluation with acquiring noises caused by the vehicle HVAC system, the simple and multiple regression models were obtained for the subjective evaluation 'Pleasant' using the sound quality metrics. The regression procedure also allows you to produce diagnostic statistics to evaluate the regression estimates including appropriation and accuracy. Furthermore, the neural network model were obtained using three inputs(loudness, sharpness and roughness) of the sound quality metrics and one output(subjective 'Pleasant'). And then the models were compared with correlations between sound quality index outputs and hearing test results for 'Pleasant'. As a result of application of the sound quality index, the neural network was verified with the largest correlation of the sound quality index.

  • PDF

The Influence of Preemployment Medical Examination, Pure Tone Audiometry, and Simple Lumbar Spine X-ray Test on the Worker's Employment - The Result of Survey at Incheon Metropolitan City and Gyeonggi Province in Korea, the Year 2003 - (채용시 건강진단과 순음청력검사 및 요추부 단순방사선 검사가 근로자 채용에 미치는 영향 - 인천, 경기 지역 2003년 실태 조사 -)

  • Kim, Kyeong-Ja;Han, Sang-Hwan;Seong, Nak-Jeong
    • Korean Journal of Occupational Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.146-155
    • /
    • 2003
  • This study was conducted for investigating the status of management of preemployment health examination and to have an effect on the worker's employment. Health managers of 103 companies in Incheon metropolitan city and Gyeonggi were interviewed by telephone. Of 103 companies, 67(65.1%) said they don't hire the applicants who have an active pulmonary tuberculosis, 80(77.7%) companies said they health HBV carrier is acceptable but active HBV carrier is not 29(28.2%) companies said they don't hire the applicants who have a hypertension or diabetes mellitus, 42(40.8%) companies said they don't hire the applicants who have a hearing disturbance. If HIVD is suspicious in X-ray lumbar-sacral region, 37(78.7% of 47 companies) said they do not hire the applicants. 29(35% of 83 companies) said they cancel the employment of the applicants who are suspicious of noise induced hearing loss on preplacement health examination. From our survey, preemployment health examination was utilizing mainly as a tool for the selection of health employees who don't have a disease. Furthermore, in many companies, additional test items are being included and getting more strict the selection criteria for preemployment health examination. For the right use of preemployment health examination, author suggested that further studies were needed to select the adequate test items and establish the reasonable criteria for preemployment health examination.

  • PDF

A Fundamental Study on the Auditory Characteristics of Amberjack Seriola dumerili in the Coast of Jeju Island (제주 연안산 잿방어의 청각특성에 관한 기초적 연구)

  • 서익조;김성호;김병엽;이창헌;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.269-275
    • /
    • 2003
  • In this paper, We examined auditory threshold and critical ratio of amberjack seriola dumerili, in the Jeju Island coastal waters, to find out hearing ability of the fish. The auditory threshold level, critical ratio and hearing index of amberjack were determinded by conditioning method using a sound coupled with electric shock in the condition of ambient noise or white noise in an experimental water tank. The audio-signals of pure tone and electric shock were from 80 HZ to 800 Hz and DC 7 V, respectively. Values for the critical ratios were calculated in terms of the masked thresholds using the noise projected to stable spectrum levels at all measurement frequencies of background noise. Masking noises were in the spectrum level range of 65 dB∼75 dB $(re 1{\mu}Pa\sqrt{Hz})$. The auditory thresholds of amberjack within the test the frequencies were most sensitive at 300HZ as 94.5 dB. The critical ratios of fishes ranged from 36.4 to 52.8 dB. The noise spectrum level that started masking was about 58∼72 dB within frequencies.

A Basic Study on Acoustic Conditioning of Fish Suitable for a Marine Ranch -1. The Sound Sensitivity of Japanese Parrot Fish Oplegnathus fasciatus- (해양목장 대상 어류의 음향순치에 관한 기초적 연구 -1. 돌돔의 청각 특성-)

  • Kim Seong Ho;Lee Chang Heon;Seo Du Ok;Kim Yong Ju
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.6
    • /
    • pp.563-567
    • /
    • 2002
  • Developing base data on luring fish schools into netting position by the use of underwater audible sound on japanese parrot fish Oplegnathus fasciatus found in the coastal waters of Jeju Island, S. Korea. Auditory threshold was determined by the heartbeat condition technique using pure tones coupled with a delayed electric shock. The audible range of japanese parrot fish extended from 80 Hz to 500 Hz with a peak sensitivity at 200 Hz. The mean auditory thresholds at the frequencies of 80 Hz, 100 Hz, 200 Hz,300 Hz and 500 Hz were 104 dB, 95 dB, 91 dB, 99 dB and 113 dB, respectively. As the frequency became higher than 200 Hz, the auditory threshold increased almost linearly with increasing frequency. Critical ratios of fishes measured in the presence of masking noise in the spectrum level range of 69$\~$78 dB (0 dB re 1$\mu$Pa/$\sqrt{Hz}$) ranged from 21 dB to 40 dB at test frequencies. The noise spectrum level at the start of masking was about 70 dB within the test frequency range. The sound pressure level of 100$\~$200 Hz recognized by japanese parrot fish under the ambient noise is above 91 dB and the critical ratio for them is above 21 dB.

Influence of Stimulus Polarity on the Auditory Brainstem Response From Level-Specific Chirp

  • Dzulkarnain, Ahmad Aidil Arafat;Salamat, Sabrina;Shahrudin, Fatin Amira;Jamal, Fatin Nabilah;Zakaria, Mohd Normani
    • Korean Journal of Audiology
    • /
    • v.25 no.4
    • /
    • pp.199-208
    • /
    • 2021
  • Background and Objectives: No known studies have investigated the influence of stimulus polarity on the Auditory Brainstem Response (ABR) elicited from level-specific (LS) chirp. This study is important as it provides a better understanding of the stimulus polarity selection for ABR elicited from LS chirp stimulus. We explored the influence of stimulus polarity on the ABR from LS chirp compared to the ABR from click at 80 dBnHL in normal-hearing adults. Subjects and Methods: Nineteen adults with normal hearing participated. The ABRs were acquired using click and LS chirp stimuli using three stimulus polarities (rarefaction, condensation, and alternating) at 80 dBnHL. The ABRs were tested only on the right ear at a stimulus rate of 33.33 Hz. The ABR test was stopped when the recording reached the residual noise level of 0.04 μV. The ABRs amplitudes, absolute latencies, inter-peak latencies (IPLs), and the recorded number of averages were statistically compared among ABRs at different stimulus polarities and stimuli combinations. Results: Rarefaction polarity had the largest ABR amplitudes and SNRs compared with other stimulus polarities in both stimuli. There were marginal differences in the absolute latencies and IPLs among stimulus polarities. No significant difference in the number of averages required to reach the stopping criteria was found. Conclusions: Stimulus polarities have a significant influence on the ABR to LS chirp. Rarefaction polarity is recommended for clinical use because of its larger ABR peak I, III, and V amplitudes than those of the other stimulus polarities.

Influence of Stimulus Polarity on the Auditory Brainstem Response From Level-Specific Chirp

  • Dzulkarnain, Ahmad Aidil Arafat;Salamat, Sabrina;Shahrudin, Fatin Amira;Jamal, Fatin Nabilah;Zakaria, Mohd Normani
    • Journal of Audiology & Otology
    • /
    • v.25 no.4
    • /
    • pp.199-208
    • /
    • 2021
  • Background and Objectives: No known studies have investigated the influence of stimulus polarity on the Auditory Brainstem Response (ABR) elicited from level-specific (LS) chirp. This study is important as it provides a better understanding of the stimulus polarity selection for ABR elicited from LS chirp stimulus. We explored the influence of stimulus polarity on the ABR from LS chirp compared to the ABR from click at 80 dBnHL in normal-hearing adults. Subjects and Methods: Nineteen adults with normal hearing participated. The ABRs were acquired using click and LS chirp stimuli using three stimulus polarities (rarefaction, condensation, and alternating) at 80 dBnHL. The ABRs were tested only on the right ear at a stimulus rate of 33.33 Hz. The ABR test was stopped when the recording reached the residual noise level of 0.04 μV. The ABRs amplitudes, absolute latencies, inter-peak latencies (IPLs), and the recorded number of averages were statistically compared among ABRs at different stimulus polarities and stimuli combinations. Results: Rarefaction polarity had the largest ABR amplitudes and SNRs compared with other stimulus polarities in both stimuli. There were marginal differences in the absolute latencies and IPLs among stimulus polarities. No significant difference in the number of averages required to reach the stopping criteria was found. Conclusions: Stimulus polarities have a significant influence on the ABR to LS chirp. Rarefaction polarity is recommended for clinical use because of its larger ABR peak I, III, and V amplitudes than those of the other stimulus polarities.

Factors Associated with Dizziness in Korean Adults (한국 성인의 어지럼 경험과 관련 요인)

  • Seo, Yeong-Mi;Lee, Eun Sook
    • Journal of muscle and joint health
    • /
    • v.31 no.1
    • /
    • pp.53-63
    • /
    • 2024
  • Purpose: This study aimed to determine the prevalence of dizziness in adults and to identify factors associated with dizziness. Methods: This cross-sectional study used secondary data from the Eighth Korea National Health and Nutrition Examination Survey. Participants included 10,265 older adults aged≥40 years. Data were analyzed using descriptive statistics, the chi-squared test, and multinomial logistic regression with the SPSS/WIN 27.0 program. Results: The prevalence of dizziness was 26.2%, with 20.9% reporting episodic dizziness and 5.3% reporting chronic dizziness. Compared to that noted in the control group participants without dizziness, the risk of episodic or chronic dizziness was higher in women and in participants with older age, low education level, low income level, high perceived stress level, depression, tinnitus, and occupational noise exposure. Moreover, the risk of chronic dizziness was higher among those with a body mass index of <25 kg/m2, stroke, cardiovascular disease, or severe hearing loss. Conclusion: The study underscores the need to comprehensively identify risk factors associated with dizziness and to develop interventions to prevent and manage the occurrence and chronicity of dizziness in the general population.

Auditory Characteristics of Tiger shark Scyliorhinus torazame caught in the Coast of jeju Island (제주 연안에서 어획된 두툽상어의 청각 특성)

  • Ahn, Jang-Young;Choi, Chan-Moon;Lee, Chang-Heon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.3
    • /
    • pp.234-240
    • /
    • 2011
  • In order to obtain the fundamental data about the behavior of sharks by underwater audible sound, this experiment was carried out to investigate the auditory characteristics of tiger shark Scyliorhinus torazame which was caught in the coast of Jeju Island by heart rate conditioning method using pure tones coupled with a delayed electric shock. The audible range of tiger shark extended from 80Hz to 300Hz with a peak sensitivity at 80Hz including less sensitivity at 300Hz. The mean auditory thresholds of tiger shark at the frequencies of 80Hz, 100Hz, 200Hz and 300Hz were 90dB, 103dB, 94dB and 115dB, respectively. The positive response of tiger shark was not evident after the sound projection of over 300Hz. At the results, the sensitive frequency range of tiger shark is narrower than that of fish that has swim bladder. In addition, it is assumed that the most sensitive frequency in auditory thresholds of Chondrichthyes is lower than that of Osteichthyes. Critical ratios of tiger shark measured in the presence of masking noise in the spectrum level range of about 60-70dB (0dB re $1{\mu}Pa/\sqrt{Hz}$) increased from minimum 27dB to maximum 39dB at test frequencies of 80-200Hz. The noise spectrum level at the start of masking was distributed at the range of about 65dB within 80-200Hz.