• Title/Summary/Keyword: Korean Artificial Heart

Search Result 283, Processing Time 0.028 seconds

Development of an Automatic Cardiac Output Control Algorithm for the Total Artificial Heart (완전 이식형 인공심장의 심박출량 자동 제어 알고리즘 개발에 관한 연구)

  • 최원우;김희찬;민병구
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.3
    • /
    • pp.38-47
    • /
    • 1995
  • A new automatic cardiac output control algorithm for the motor-driven electromechanical total artificial heart(TAH) was developed based on the motor current waveform analysis without using any extra transducer. The basic control requirements of artificial heart can be described in terms of three features : preload sensitivity, afterload insensitivity, and balanced ventricular outputs. In the previous studies, many transducers were utilized to obtain informations of hemodynamic states for the automatic cardiac output control, But such automatic control systems with sensors have had reliability problems. We proposed a new sensorless automatic cardiac output control algorithm providing adequate cardiac output to the time-varying physiological demand without causing right atrial collapse, which is one of the critical problem in an active-filling type device. In-vitro tests were performed on a mock circulation system to evaluate the performance of the developed algorithm and the results show that the new algorithm satisfied the basic control requirements on the cardiac output response and the possibility of application of the developed algorithm to in vivo experiments.

  • PDF

A Study on the Practical Estimation of Nonlinear Hemodynamic Variables for the Moving-Actuator type Total Artificial Heart (인공심장의 비선형 혈류 역학 변수 예측에 관한 연구)

  • 엄경식;안재목
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 1998
  • It is needless to say that the nonlinear hemodynamic variables estimation is a very important study for the artificial heart. Even though it is important, there have not been satisfactory results which can be applied to the real world situations, In this paper, the problem of hemodynamic variables estimation for the moving-actuator type total artificial heart(MA-TAH) was studed. Multidimensional linear interpolation(MDI)scheme was used for the estimation. Proposed method was verified by in vitro test and showed good performance.

  • PDF

Application of Endoscopic Ultrasound-based Artificial Intelligence in Diagnosis of Pancreatic Malignancies (악성 췌장 병변 진단에서 인공지능기술을 이용한 초음파내시경의 응용)

  • Jae Hee Ahn;Hwehoon Chung;Jae Keun Park
    • Journal of Digestive Cancer Research
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2024
  • Pancreatic cancer is a highly fatal malignancy with a 5-year survival rate of < 10%. Endoscopic ultrasound (EUS) is a useful noninvasive tool for differential diagnosis of pancreatic malignancy and treatment decision-making. However, the performance of EUS is suboptimal, and its accuracy for differentiating pancreatic malignancy has increased interest in the application of artificial intelligence (AI). Recent studies have reported that EUS-based AI models can facilitate early and more accurate diagnosis than other preexisting methods. This article provides a review of the literature on EUS-based AI studies of pancreatic malignancies.

Changes of the Electrocardiogram and Blood Picture of Frogs in Four Seasons (개구리 심전도(EKG) 및 혈액상의 계절에 따른 변화)

  • Rhee, Jung-Moo;Bae, Sung-Ho;Shin, Hyun-Chan;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.33-44
    • /
    • 1974
  • The electrocardiogram of frogs were obtained in winter (January), spring (April), summer (July) and autumn (September and November). Electrocardiograms were recorded applying electrodes to the atria, ventricle and apex of the heart by unipolar or bipolar leads. V wave was recorded prior to P wave, for the presence of the sinus venosus which controls the automaticity of the frog heart, in four seasons. Regardless of the leads or the position of the electrodes P wave was diphasic and wide. According to the rise of temperature the rate of heart beat was increased, and V-P and P-R interval were shortened. Two regression line between R-R interval and both V-P interval and P-R interval were drawn. These were calculated as V-P interval=1 0.276R-R $interva1+0.067{\pm}0.15$ (sec.) and P-R interval=0.179R-R $interva1+0.155{\pm}0.1$ (sec). From these calculation the larger gradient of V-P interval than P-R interval was suggestive that the heart rate is more dependent on the changes of V-P interval than that of P-R interval. Changes of the heart rate were also measured in four seasons and artificial temperatures. Two regression lines between the heart rate (H.H.) and both seasonal temperature (T) and artificial temperature, were drawn. These two lines were calculated as H.R.=20+3.71 (T-10) and H.R.=32+1.425 T respectively. From two gradients of the above equations it is considered that the changes of the heart rate in artificial temperature were milder than that in seasonal temperature. The number of RBC and WBC of frogs were measured in four seasons and a tendency of the changes was observed according to the seasonal variation.

  • PDF

In vitro study of downstream flow passing through heart valve prostheses (인공 심장판막 하류 유동의 in vitro 연구)

  • Kim Hyoung-Bum;Lanning Craig
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.1
    • /
    • pp.47-55
    • /
    • 2006
  • The left ventricular filling flow is now considered as an indicator which can be used for early diagnosing of cardiovascular diseases. Because the understanding of left ventricular flow physics is critical for this purpose, the downstream flow characteristics of the artificial heart valve are investigated using particle image velocimetry (PIV) method. In this study, we investigated the wake characteristics of flows passing through three different artificial valves (St.Jude medical bileaflet mechanical valve. Bjork-Shiley monostrut mechanical valve and St.Jude medical Biocor bio valve). The downstream flow field has remarkably altered according to the different valves. SJM MHV has the flow field similar to the pulsating circular jet and BS MHV has oblique pulsating jet. SJM BHV shows the similar flow field of clinical data of normal heart.

  • PDF

Nonlinear Analysis of the Monoleaflet Polymer Valve According to Shape of Supporting Members (지지대 형상에 따른 단엽식 고분자 판막의 비선형 해석)

  • 한근조;안성찬;심재준;김성윤
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.748-751
    • /
    • 2001
  • Monoleaflet polymer artificial heart valve was known to show remarkable improvement in antithrombosis and pressure drop compared with other type of artificial valve. In this investigation monoleaflet the vertical and horizontal deflection pattern of polymer heart valve with three types of supporting members straight member, and two curved members was analysed using the large deformation nonlinear finite element method.

  • PDF

Design and Analysis of Motor-Driven Artificial Heart ( II );Analysis (모터 구동형 인공심장의 설계 및 해석(II) 해석)

  • 천길정;한동철;민병구
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.3
    • /
    • pp.855-868
    • /
    • 1991
  • 본 연구에서는 위에서 언급한바와 같은 제반사항들에 대해 이론적인 해석을 행하고, 그 결과를 이용하여 설계된 모델이 생체내에 이식될 수 있는 가능성의 여부를 판단하며 생체내에 이식 되었을 때의 성능과 생체에 미치는 영향등을 예측하고자 한다.

A Study of the Acoustical Properties of the Mechanical Heart Valve Using MUSIC (MUSIC을 이용한 기계식 심장 판막의 음향 신호 특성 연구)

  • Yi S. W.;Choi M. J.;Min B. G.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.131-134
    • /
    • 1999
  • This paper considers the acoustical characteristics of the mechanical valve employed in the Korean type Artificial Heart. $Bj\"{o}rk-Shiley$ tilting disc valve was chosen for the study and acoustic measurements were performed for the artificial heart operated in a mock circulation system as well as implanted to an animal as a Bi Ventricular Assist Device (BVAD). In the mock system, three different conditions of the valve were examined which were normal, damaged (torn off), pseudothrombus attached. Microphone measurements for the BVAD were carried out at a regular time interval for 5 days after the implantation operation. Of the recorded acoustic emissions from the artificial heart, click sounds mainly originated from the valves were further analyzed using Multiple Signal Classification (MUSIC) for estimating their spectral properties. It was shown that the spectral peaks below 4 kHz and the optimal order number for MUSIC, equivalent to the number of the spectral component, might be the key parameters which were highly correlated to the physiological states of the valve like the mechanical damage of the valve or the formation of thrombus on the valves.

  • PDF

Design of a Mechanical Artificial Heart Valve Prosthesis Appliing Design Methodology (설계방법론을 이용한 기계식 인공심장판막의 설계)

  • 천길정;류형태
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.291-296
    • /
    • 1998
  • A new mechanical heart valve prosthesis has been designed appling systematic design methodology. The function of the heart valve was defined, and search for design variation has been carried out according to the functional structure, Optimal model among the various variations was determined in view of the design specificationn. Proto type valve was fabricated and test has been carried out using a mock circulation system. It has been observed that the pressure profile, cardiac output and behavior characteristics are generally satisfactory.

  • PDF