References
- IEEE Trans. Biomedical Engineering v.37 no.12 A moving-actuator type electromechanical total artificial heart-part I:linear type and mock circulation experiments B. G. Min;H. C. Kim;S. H. Lee;J. W. Kim;J. T. Kim;I. Y. Kim;S. W. Kim;P. D. Diegel;D. B. Olsen
- IEEE Trans. Biomedical Engineering v.37 no.12 A moving-actuator type electromechanical total artificial heart-part II: Circular type and animal experiment B. G. Min;H. C. Kim;J. W. Choi;G. H. Ryu;K. P. Seo;J. R. Rho;H. Ahn;S. W. Kim;P. D. Diegel;D. B. Olsen
- Waseda International Congress of Modeling and Simulation Technology for Artificial Organs Modeling technique for development of the moving-actuator total artificial heart B. G. Min;S. J. Kim;M. J. Choi;W. W. Choi;S. K. Park
- Waseda International Congress of Modeling and Simulation Technology for Artificial Organs Estimation of atrial pressure in a totally implantable artificial heart S. J. Kim;S. K. Park;M. J. Choi;B. G. Min
- Waseda International Congress of Modeling and Simulation Technology for Artificial Organs The compliance model of the inter-ventricular space in the moving-actuator type total artificial heart S. K. Park;M. J. Choi;S. J. Kim;B. G. Min
- KOSOMBE Spring Conference v.18 no.1 A simplified model for compliance determination of the moving-actuator type totally implantable artificial heart S. K. Park;W. W. Choi;J. M. Ahn;S. J. Kim;J. S. Choi;Y. H. Jo;K. S. Om;J. J. Lee;H. C. Kim;M. J. Choi;B. G. Min
- M. S. Dissertation, Dept. of Biomedical Engineering, Seoul National University Analysis of the interventricular pressure wave-form in the moving-actuator type total artificial heart Y. H. Jo
- J. of Korea Fuzzy Logic and Intelligent Systmes v.6 no.4 Relation between multidimensional linear interpolation and fuzzy reasong K. S. Om;B. G. Min
- J. of Korea Fuzzy Logic and Intelligent Systems v.7 no.3 Relation between multidimensional linear interpolation and regularization networks K. S. Om;B. G. Min
- KOSOMBE Spring Conference Experimental approach for the estimation of cardiac out-put of left ventricular assist device using multi-dimensional interpolation technique K. S. Om;W. W. Choi;J. M. Ahn;S. K. Park;Y. H. Jo;J. S. Choi;J. J. Lee;H. C. Kim;B. G. Min
- Fundamentals of Digital Image Processing A. K. Jain
- IEEE Trans. on Syst. Man, and Cybern. v.SMC-24 no.2 Interpolation, completion, and learning fuzzy rules T. Sudkamp;R. J. Hammell II
- Numerical Recipes in C W. H. Press
- Ph. D. Dissertation, Dept. of Biomedical Engineering, College of Engineering, Seoul National University Preload-sensitive Control and Cardiac Output Estimation using Fuzzy Logic Algorithm in the Moving-actuator type Total Artificial Heart W. W. Choi
- IEEE Trans. Circuits and Syst. v.CAS-38 no.9 Center weighted median filters and their applications to image enhancement S. J. Ko;Y. H. Lee
- KOSOMBE Fall Conference v.18 no.2 Static arotic pressure model for a moving-actuator type total artificial heart K. S. Om;J. M. Ahn;S. K. Park;Y. H. Jo;H. C. Kim;B. G. Min
- J. of Artificial Organs v.15 no.2 Investigation of parameter estimator and adapive controller for assist pump by comptuter simulation T. Shimooka;Y. Mitamura;T. Yuhta
- IEEE Trans. Biomedical Engineering v.37 no.4 An adaptive aortic pressure observer for the penn state electric ventricular assist device U. Tasch;J. W. Koontz;M. A. Ignatoski;D. B. Geselowitz
- J. of KOSOMBE v.17 no.3 Adaptively trained artificial neural network identification of left ventricular assist device S. H. Kim;H. M. Kim;J. W. Ryu