• Title/Summary/Keyword: Korea Design Standard

Search Result 3,774, Processing Time 0.036 seconds

A Study on Determination of Capacity for Pump and Detention Pond in Small Basins for Flood Control (소유역에서 홍수조절용 펌프 및 유수지 규모의 결정에 관한 연구)

  • Ahn, Tae-Jin;Park, Jong-Yoon;Lyu, Heui-Jeong;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.3 s.134
    • /
    • pp.385-398
    • /
    • 2003
  • The concept of the effective storage ratio has been suggested to determine the size of detention pond by the previous researchers. The 11 pump - pond facilities in Dongdu-chun city were selected to analyze the critical duration for design rainfall and the storage ratio for each rainfall duration in this study It has been then found that the criteria of the maximum storage ratio is not reasonable for determining the size of detention pond because the difference of storage ratio with respect to each rainfall duration is too small. Moreover, since the size of pond compared with the pump capacity is not always big enough, the pump should be frequently operated, which may result in pump failure. Thus, the pond should be sufficiently sized to prevent the possibility of the pump failure due to frequent operation. According to the analyses for changing pump capacity, it has been found that if the function of the pond compared with the pump is concentrated, determining the size of pond based on the storage ratio is operationally feasible for even small basin. Thus, an improved procedure based on the storage ratio for determining the size of detention pond in small basin has been suggested. The results by the proposed procedure considering pump switching frequency may lead to reasonable pump operation. A simple linear programming model has been also adopted to figure out the relationship between pump capacity and pond size. It has been shown that the determination lot the size of detention pond based on conventional hydrologic flood routing in pond is feasible for only urban districts not rural areas.

A Study on the Effects of Various Disk Shape of Hydrant on the Pressure Drop (옥외소화전의 디스크 형상을 고려한 압력손실에 관한 연구)

  • You, Woo Jun;Shim, Myoung Gyu;Sung, Kun Hyuk;Yu, Jae Bum;Youm, Moon Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.1-7
    • /
    • 2013
  • In this study, the effects of various disk shapes of hydrant on the pressure drop are experimentally and numerically analyzed. The test methods for measuring pressure drop of hydrant are comply with standard of Underwriters Laboratory (UL). The hydrant as used in this study has one inlet, diameter 150 mm, and three outlet, 114.3 mm diameter for one outlet and 63.5 mm diameter for the others. The pressure of the hydrant are measured in the range 760 L/min~2,270 L/min for 63.5 mm outlet and 3,030 L/min~6,060 L/min for 114.3 mm outlet. Also, the numerical results of pressure drop are compared with the experiments to verify the accuracy and to analyze the of various valve shape of hydrant on the pressure drop. The engineering parameters, flow coefficients, are reduced from 181.57 to 136.35 ($L/min/kPa^{0.5}$) with inclined angle of disk from $0^{\circ}$ to $45^{\circ}$. These results are able to practical use for design hydrant to minimize pressure drop.

Case Study for Analysis of Technology Convergence Structure with Social Network Analysis (기술융합 구조 분석을 위한 사례연구: 2-mode 네트워크분석 활용)

  • Lee, Kwang-Min;Hong, Jae-Bum
    • Journal of Technology Innovation
    • /
    • v.24 no.2
    • /
    • pp.1-20
    • /
    • 2016
  • This case is to analyze the structure of technology convergence with social network analysis. More specifically, the convergence structure among input technologies mediated with products is analyzed with 2-mode social network analysis. Products are identified in project's goal and coded as the Korea Standard Industrial Classification. The input technologies are coded as the National Science Technology Classification. The subjects were 401 R&D projects applied to '2012 Convergence Technology Development Project for Small and Medium Businesses' promoted by Korea Technology & Information Promotion Agency for Small and Medium Enterprises. IT sectors had the structure of a particular input technology connected to many products, BT sectors also had a few input technology connected to many products but most were connected to specific products. Therefore We have realized that each convergence area had different convergence structure. There were the difference of connectivity centrality between input technologies and input technologies mediated with products. For IT sectors, the embedded S/W were the highest in both cases. For BT sectors, functional cosmetic development and fermentation technology were the highest in input technologies but fermentation technology was not the highest in input technologies mediated with products. This case defines the convergence based on the real projects and the use for managing and planing projects. Therefore, this case was to make a tool to analyze and design technology convergence projects.

The Comparative Quantitative Risk Assessment of LNG Tank Designs for the Safety Improvement of Above Ground Membrane Tank (지상식 멤브레인 LNG저장탱크 안전성 향상을 위한 설계형식별 정량적 위험성 비교 평가)

  • Lee S.R.;Kwon B.G.;Lee S.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.4 s.29
    • /
    • pp.57-61
    • /
    • 2005
  • The objective of paper is to carry out a comparative Quantitative Risk Assessment (QRA) of two KOGAS tank designs using a fault tree methodology, a standard 'Full Containment' tank and a 'Membrane' tank. For the membrane tank, both the initial KOGAS design and 4 modified KOGAS designs have been assessed, giving six separate cases. In this paper, the frequencies of releases are quantified using a fault tree approach. For clarity in the analysis, and to ensure consistency, all cases have been quantified using the same fault tree. Logic within the fault tree is used to select each of the cases. Full quantification of risks is often difficult, owing to a lack of relevant failure data, but the aim of this study has been to be as quantitative as possible, with full transparency of failure information. The most significant general cause of external LNG leaks is predicted to be a seismic event, which has been quantified nominally. 4modified KOGAS desiens to Prevent damage of bottom membrane panels that was shown in preparatory estimation could quantitively confirm safety improvement. According to result, the predicted frequencies of an external LNG leak for the full containment and modified membrane tanks are very similar, failures due to dropped pumps are predicted to be significantly greater for the membrane tank with thickened plate than for the full containment tank.

  • PDF

An Establishment of Functional Test Facility for ICT-Convergence Equipment of Vessel : Focused on Maritime Digital Interfaces and Main Navigation Communication Systems (선박 ICT융합 장비 기능시험 시설 구축 연구 : 선박 디지털 인터페이스 및 주요 항해통신장비를 중심으로)

  • Hwang, Hun-Gyu;Kim, Bae-Sung;Woo, Snag-Min;Woo, Yun-Tae;Shin, Il-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.5
    • /
    • pp.754-763
    • /
    • 2018
  • The maritime ICT-convergence equipment are essentially required to a type approval (TA) certification that needs environmental and functional tests, to install in vessel. The environmental test is to experiment the possession for required durabilities of the target device in maritime environment, and the functional test is to check the required functions of target equipment based on international standard. In Korea, the environmental testing facilities amount to 227 sites, but there is no functional testing facility. Because of this, we establish a function test facility for the maritime ICT-equipment. In this paper, we analyze and design the functional testing requirement and required interlocking simulators for digital interfaces and navigation communication equipment. We propose the 2-steps of functional testing procedures, which are single test and integration test, to improve the reliability of testing result. The single test is to examine own functions of the target device, and the integration test is to check harmonized operation with other navigation and communication devices.

A Study of Innovation Policy regarding Technical Regulation and Conformity Assessment Procedure on ICT Equipments - Focused on Privatization Plan (CT 분야의 기술기준 및 적합성평가시스템의 혁신정책에 관한 연구: 민간화 방안을 중심으로)

  • Lee, Yong-Kyu
    • Journal of Korea Technology Innovation Society
    • /
    • v.19 no.3
    • /
    • pp.439-464
    • /
    • 2016
  • The technical regulation and conformity assessment procedure of our country on ICT equipments is currently required to have more innovation due to the request of main trade countries, the second phase conclusion of MRA, necessity of expansion of conformity assessment service market and demand of manufacturers. The world's leading advanced countries have already proceeded with innovation based on privatization plan. According to the comparative analysis of the level, it turned out that Japan obtained the highest level of privatization while South Korea ranked the lowest level. According to the research result of examination and certification ability of private institutions of our country, it turned out that our country is expected to have possibility of achieving higher level of privatization than that of the present. Moreover, according to the questionnaire survey conducted to the persons concerned regarding privatization direction, they gave positive response to all the indicated survey contents of privatization direction in terms of "delegation of certification services to private sectors (contracting-out)", "transformation of EMC into private voluntary standard" and "changeover of conformity assessment agent". However, from the view of acceptance and conflict model, it is estimated that starting from "delegation of certification services to private sectors (contracting-out)" seems to be the most advisable plan. Also, prior to privatization, it is required to improve relevant systems such as certification examiner system.

An Analysis and Industrial Classification of Modeling and Simulation Service Industry (모델링 및 시뮬레이션 서비스 산업 분류 및 현황 분석)

  • Kim, Myungil;Jung, Jaeyun;Han, Yuri;Park, Sung-Uk;Kim, Jaesung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.185-198
    • /
    • 2017
  • Since the year 2000, the growth rate of domestic manufacturing has declined and the sales and employment have decreased. Major developed countries have established a variety of strategies to strengthen their manufacturing competitiveness, and promote manufacturing innovation through the convergence of technology and ICT. The key to manufacturing innovation is to reduce the time and cost for developing new products using modeling and simulation (M&S) technology in the product design stage. M&S industries, which belong to the top sector of the industry value chain, have a huge ripple effect across other industries. On the other hand, the competitiveness of the domestic M&S industry is weak compared to developed countries and even the definition and classification of domestic M&S companies have not been made. In this paper, by analyzing the Korea Standard Industry Classification (KSIC), five fine industry classifications included in M&S service companies were derived. In addition, the 307 M&S service companies were derived in accordance with the selection procedure of 3 steps from the 11,822 related companies. To analyze the capabilities of domestic M&S service companies, the current status of the selected M&S service companies was investigated. Considering the Korean economy's high dependence on the manufacturing industry, strengthening the competitiveness of manufacturing industry is required by enhancing the capacities and building an ecosystem in domestic M&S services for future sustainable economic growth.

Design of a Block-Based 2D Discrete Wavelet Transform Filter with 100% Hardware Efficiency (100% 하드웨어 효율을 갖는 블록기반의 이차원 이산 웨이블렛 변환 필터 설계)

  • Kim, Ju-Young;Park, Tae-Guen
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.12
    • /
    • pp.39-47
    • /
    • 2010
  • This paper proposes a fully-utilized block-based 2D DWT architecture, which consists of four 1D DWT filters with two-channel QMF PR Lattice structure. For 100% hardware utilization, we propose a new method which processes four input values at the same time. On the contrary to the image-based 2D DWT which requires large memories, we propose a block-based 2D DWT so that we only need 2MN-3N of storages, where M and N stand for filter lengths and width of the image respectively. Furthermore, the proposed architecture processes in horizontal and vertical directions simultaneously so that it computes the DWT for an $N{\times}N$ image within a period of $N^2(1-2^{-2J})/3$. Compared to existing approaches, the proposed architecture shows 100% of hardware utilization and high throughput rate. However, the proposed architecture may suffer from the long critical path delay due to the cascaded lattices in 1D DWT filters. This problem can be mitigated by applying the pipeline technique with maximum four level. The proposed architecture has been designed with VerilogHDL and synthesized using DongbuAnam $0.18{\mu}m$ standard cell.

Analysis of Cyclic Loading Transferred Mechanism on Geosynthetic-Reinforced and Pile-Supported Embankment (토목섬유로 보강된 성토지지말뚝 시스템의 반복하중 전이 메커니즘 분석)

  • Lee, Sung-Jee;Yoo, Min-Taek;Lee, Su-Hyung;Baek, Min-Cheol;Lee, Il-Wha
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.12
    • /
    • pp.79-91
    • /
    • 2016
  • Geosynthetic-reinforced and Pile-supported (GRPS) embankment method is widely used to construct structures on soft ground due to restraining residual settlement and their rapid construction. However, effect of cyclic loading has not been established although some countries suggest design methods through many studies. In this paper, cyclic loading tests were conducted to analyze dynamic load transfer characteristics of pile-supported embankment reinforced with geosynthetics. A series of 3 case full scale model tests which were non-reinforced, one-layer-reinforced, two-layer reinforced with geosynthetics were performed on piled embankments. In these series of tests, the height of embankment and pile spacing were selected according to EBGEO (2010) standard in Germany. As a result of the vertical load parts on the pile and on the geosynthetic reinforcement measured separately, cyclic loads transferred by only arching effect decreased with strength geosynthetic-reinforced case. However, final loads on the pile showed no differences among the cases. These results conflict with previous studies that reinforcement with geosynthetics increases transfer load concentrated on piles. In addition, it is observed that the load transferred to pile decreases at the beginning of cycle number due to reduction of arching effected by cyclic loading. Based on these results, transferred mechanism for cyclic load on GRPS system has been presented.

Strength Parameters and Shear Behaviors of North-Cheju Basalt Rubble Using Large-scale Triaxial Test (대형삼축압축시험을 이용한 북제주현무암 사석재의 강도정수 및 전단거동)

  • 정철민;김종수;채영수
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.2
    • /
    • pp.147-160
    • /
    • 2002
  • According to the Korean Design Code for port and harbor facilities, bearing capacity of rubble mound under eccentric and inclined load is calculated by the simplified Bishop method, and strength parameters are recommended to be c=0.2kg/$cm^2$ and \phi=35^P\circ}$ fur standard rubble if the compressive strength of parent rock is greater than 300kg/$cm^2$, according to research results by Junichi Mizukami(1991). But this facts have never been verified in Korea because there was no large-scale triaxial test apparatus until 2000 in Korea. For the first time in Korea, the large-scale triaxial test(sample diameter 30cm ; height 60cm) on the rubble originated from porous basalt rock in North-Cheju was accomplished. Then strength parameters for basalt rubble produced in North-Cheju are recommended to be c:0.3kg/$cm^2\; and \phi=36^{\circ}$ if the compressive strength of parent rock is greater than 400kg/$cm^2$. And the shear behavior characteristics of rubble, represented as particle breakage and dilatancy, are investigated.