• 제목/요약/키워드: Kitchen Ventilation

검색결과 75건 처리시간 0.025초

주방 환기에 대한 조리사들의 인식도 연구 - 서울 지역을 대상으로 - (A Study on the Recognition of Cooks about the Kitchen Ventilation)

  • 반주원;허준
    • 한국조리학회지
    • /
    • 제11권4호
    • /
    • pp.228-244
    • /
    • 2005
  • The objective of the study is to observe cooks first from the kitchen and those who care health and to grasp the impression regarding the kitchen environment. Also, it grasped the recognition degree of cooks against the elements of kitchen ventilation and kitchen ventilation equipments. We surveyed against 385 cooks who work in the kitchen of special grade hotels and family restaurants, used 5 scales for the object, and executed the analysis. The results of this study are as follows: (1) Health condition of the cooks appeared most highly pain in the shoulder and the neck. (2) for the impression regarding the kitchen environment, temperature was high and the insufficiency of ventilation is answered highly. (3) The importance of kitchen ventilation of cooks was recognized very high. (4) The combustion gas was recognized as very high percentage and the most effective element of the kitchen on the human body to remove first inside the kitchen. (5) Most cooks were recognized that the improvement of ventilation equipments is necessary. (6) The object of ventilation equipments is appeared to maintain comfortable kitchen environment. (7) The optimum operation method of ventilation equipment uses the automatic system of ventilation equipment from the kitchen and it is necessary to maintain the optimum. This research is based on preceding studies, investigating special grade hotels and family restaurants in Seoul. The ventilation plan of the kitchen should be accomplished to improve the health of cooks and productivity.

  • PDF

경남지역 학교 급식조리실 개선 전후 환기성능 평가 (Evaluation of Ventilation Effectiveness Before and After Kitchen Renovation in Schools of Gyeongsangnam-do)

  • 손종원;김태형;하현철;김병훈
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.35-47
    • /
    • 2024
  • Objectives: Many cases of lung cancer have been reported by school kitchen workers as occupational cancer. Twenty-eight schools in Gyeongsangnam-do Province were selected to evaluate the effect of improved kitchen ventilation systems. Ventilation characteristics before and after renovation were compared and design techniques were identified. Methods: In the design stage for kitchen ventilation systems, expert intervention was used to improve the designs. Ventilation characteristics and air quality were evaluated before and after the renovations. Hood face velocity and fan flow rate were measured and the smoke visualization technique was used to evaluate the capability of protecting worker's breathing zone. The concentrations of PM0.3 were measured at points not adjacent to cooking equipment because these concentrations fluctuate greatly. Results: Mean hood face velocity increased from 0.29 m/s before renovation to 0.7m/s after renovation. The concentrations of PM0.3 showed a roughly 95% reduction. Concentrations of CO showed more than a 75% reduction. Smoke visualization showed greater protection of workers' breathing zone. Conclusions: Advanced design techniques for school kitchen ventilation systems were applied to renovate old kitchen ventilation systems. The performance of the new kitchen ventilation systems was nearly excellent. Further improvement of design techniques is still needed, however.

가스를 연료로 사용한 주방에서의 오염물질 발생 특성에 대한 연구 (A Study on the Occurrence Character of Contaminant in the Kitchen that Use Gas Fuel)

  • 박명길;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2001년도 학술발표대회논문집
    • /
    • pp.77-82
    • /
    • 2001
  • This paper is contents that measure the ventilation rates and temperature by driving condition of exhaust fan, vapor, contaminant occurrence amount of carbon dioxide etc. In kitchen of apartment house. The ventilation rates in the apartment kitchen measured by Tracer Gas Method. And, temperature of when cook by gas table hood lower part 10cm and floor upside 10cm of kitchen central part, 120cm, 210cm heights measure. As ventilation rates measurement result, ventilation number of times was 0.7(number of times/hour) when did not to operate exhaust fan. but we were measured by 2.3(number of times/hour) when drove strongly. As temperature measurement result at cooking by gas table, temperature showed highest in hood lower part 10cm of case that do not operate exhaust fan. Temperature at kitchen central was most low in 10cm height in talc floor, and 210cm were measured highest. Concentration of carbon dioxide is very high by 4,350ppm after measurement time 10 minutes in state who do not operate exhaust fan at cooking by gas table.

  • PDF

선박용 주방후드 환기시스템에 관한 수치해석 (Numerical Analysis of the Kitchen Hood Ventilation System for Marine Environment)

  • 이중섭
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.96-101
    • /
    • 2015
  • This study regards distributions of flow in the ventilation system used in the kitchen hood in a ship. In this study, for describing the flow in the ventilation system, three-dimensional steady-state turbulence was assumed for the governing equation. When the plume was formed, three gases, CO, CO2, and HCL, in the flow field of the hood were considered as the plume, and it was assumed that the sum of concentrations of the gases was 100%. As a result, it could be confirmed that the plume was smoothly discharged when the flow rate of the supply was ten times lower than that of the exhaust.

부엌공기 중에 함유되어 있는 가스량과 부엌 구조시설 연료관리와의 관계에 대한 연구 (A Study on the amount of Co gas in the kitchen related to facility enviromental condition and fuel management)

  • 장명욱
    • 대한가정학회지
    • /
    • 제8권1호
    • /
    • pp.146-158
    • /
    • 1970
  • It is a matter of amazing to realize that contamination of air by fuel gas in recent daily life at home directly effects to health of Korean housewives. A study in finding the status and the amount of co gas in the kitchen was con-ductedrelating the size of kitchen, door of exit, ventilation window, constraction of built in-brick stove (Boo Tu Mack), fuel management, in order to extend beneficial and improved management of housing. From the result of study, it was pointed out that constractional improvement of built-in-brick stove, heating floor (Ondol), timny, and ventilation window would been emergently needed. Demonstration studies were obtained in finding differences of the amount of co gas respectively in cooking time as 50-55ppm, and in not cooking time as 50-80p,p,m in the kitchen both, original and improved. Definite differences were found depend upon the condition with, without, or direction of the ventilation window. In addition to all above results, significant influence on gas pulling power of Ondol tunnel was shown. Many houses of Apartment house for have middle and low income groups been recognized so poor for health as indicated over 100ppm of co gas if window were not opened because of poor ventilation and weak gas pulling power of Ondol tunnel.

  • PDF

공동주택의 주방에서 사용되는 시판 환풍기의 환기 성능 평가에 관한 연구 (A Study on the Ventilation Performance Estimation of Marketing Ventilation Fan Used in the Apartment House Kitchen)

  • 송필동;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.315-320
    • /
    • 2002
  • Marketing ventilation fan 3 kinds been using in kitchen of apartment house into compensation discharge performance of contaminant measure. When propane gas burns by gas table, did waste heat into measurement compensation with carbon dioxide that it happens. In measured all type of exhaust fan, discharge performance of carbon dioxide and waste heat was high there are been much displacement. Among A, B, C three types, performance of A type exhaust fan was most superior and performance of C type exhaust fan was most poor

  • PDF

공동주택에서 환기장치류 가동특성에 따른 실내공기질 변화특성에 관한 연구 (The Effects to Indoor Air Quality as Ventilation System Operation in Apartment House Using CFD Simulation)

  • 김석근;이정재
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.142-148
    • /
    • 2007
  • The purpose of this study is to suggest the effective ventilation strategies and control methods that can minimize energy cost maintaining acceptable IAQ level in apartment house. The effects of the air-cleaning and heat-recovery ventilation system on IAQ under various operating conditions are investigated based on the experimental and CFD analyzed results. The results can be summarized as follows. (1) When a ventilator is not operated, the concentration of several pollutants may highly show in the house even though environment-friendly building materials are applied. Therefore, a mechanical ventilation system is required to obtain proper ventilation. (2) The pollutant concentration is noticeably deceased under air-cleaning/ventilation mode of air-clinic system, however, pollutant of kitchen is stagnant, because fresh air is not carried into the kitchen. (3) When air-clinic system is only equipped at master bedroom and living room, the system does not effectively deliver fresh air throughout the whole house, and then high pollutant concentration is obtained in each room. In contrast the average pollutant concentration meets the guideline when air-clinic system is installed at each room. (4) The air-cleaning/ventilation mode significantly affects on room ventilation in comparison with ventilation mode only.

기술사 마당 - 주방 후드 부스타 배기 방식

  • 진남기
    • 기술사
    • /
    • 제45권6호
    • /
    • pp.44-51
    • /
    • 2012
  • Local functional, closed the hood and exhaust are classified as open-style hood. Around the closed hood contaminants prevent the spread of contaminants. Surrounded Some pollutants (open-style hood is used in cases where the odor, vapor diffusion, and inferior) of indoor allowed to Hood expressions, which are used for kitchen, laboratory, factory canopy is typical. Contamination that occurs during cooking, kitchen ventilation barrier materials are the biggest problem, its solution by introducing fresh outside air in the kitchen troubleshoot and. Study on the kitchen exhaust airflow for my kitchen, and perform a number of each Institute and at the University of hydrodynamic analysis is investigated.

  • PDF

공동주택 주방의 급ㆍ배기효율을 고려한 기계환기 설계에 관한 연구 (A Study on the Mechanical Ventilation Design that Consider Supply and Exhaust Efficiency of the Apartment House Kitchen)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.101-108
    • /
    • 2004
  • To find more efficient exhaust effect, air curtain of upward or downward trend in gas table and left or right side of range hood were made. As result that film vapor from range hood lower part by digital camera, the air current change by moving existence and nonexistence of exhaust fan and direction of air curtain were known. Under all experiment condition, upward air curtain superior exhaust performance.

선박용 주방 환기후드의 성능평가에 관한 연구 (Study on Performance Evaluation of Marine Kitchen Ventilation Hood)

  • 김동규;정용현;금종수
    • 수산해양교육연구
    • /
    • 제26권6호
    • /
    • pp.1373-1379
    • /
    • 2014
  • The purpose of this research is to evaluate the performance of the Ventilation hood and to make better oil collection for improvement. In order to complete the purpose, the research range has limited a kitchen cooking utensil used in preparing food in vessels. Assessment was carried out with reference(ASTM F1704-09) to the specification. Evaluation items of ventilation hood were flow visualization, oil collection rate and noise levels. When filter angle was 40 degrees, oil collection rate was increased by 9%.