• Title/Summary/Keyword: Kim. Han-sup

Search Result 1,128, Processing Time 0.026 seconds

Properties of Shrinkage and Strength of Concrete Incorporating Blast-furnace Slag (고로슬래그 치환율 변화에 따른 고강도 콘크리트의 강도 및 수축 특성)

  • Son, Ho Jung;Noh, Sang-Kyun;Kim, Seoung Hwan;Han, Min Cheol;Baek, Joo Hyun;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.99-102
    • /
    • 2008
  • This study investigates the properties of the flow, air content, strength, hydration heat, and the autogenous shrinkage, and the results are summarized as following. As a properties of fresh concrete, the flow increased and the air content decreased as the replacement ratio of BS increased. The time of set delayed as the replacement ratio of BS increased by latent hydraulicity. The compressive strength of hardening concrete was smaller than OPC as the replacement ratio of BS increased at young concrete, however it was more than equal after 28th day and from then on. The rising temperature ratio which occurs by simplicity insulation decreased as the replacement ratio of BS increased, but it increased by latent hydraulicity reaction at the latter half. The length ratio of autogenous shrinkage of OPC was 319×10-6, however it was shorter when the replacement ratio was 40% as showing 290×10-6.

  • PDF

Safety and efficacy of pemetrexed for the treatment of lung adenocarcinoma in patients with various stages of chronic kidney disease

  • Yang, Jieun;park, Ji Eun;Jo, Jaemin;Kim, Young Ree;Chang, Jee Won;Han, Sang Hoon;Han, Chi Wha
    • Journal of Medicine and Life Science
    • /
    • v.19 no.1
    • /
    • pp.14-19
    • /
    • 2022
  • We investigated the safety and efficacy of pemetrexed monotherapy in patients with lung adenocarcinoma and various renal conditions, including chronic kidney disease. We also analyzed whether baseline renal function affected progression-free survival (PFS). We retrospectively analyzed 71 patients who received maintenance-and second-line pemetrexed monotherapy. Patients were divided into two groups according to estimated glomerular filtration rate (eGFR): fair eGFR (>60 mL/min/1.73 m2) and lower eGFR (59 mL/min/1.73 m2 or less). The safety and efficacy were evaluated for each group. Median ages were 73.2 years in the lower eGFR group (n=28) and 64.5 years in the fair eGFR group (n=43). Patients with a lower eGFR achieved a median PFS of 4.7 months, while the median PFS for patients with a fair eGFR was 2.7 months. The difference between the two groups was not statistically significant (P=0.075). Both groups showed treatment-related low-grade hematological and non-hematological adverse events. Pemetrexed monotherapy is safe and effective in patients with lung adenocarcinoma with a lower eGFR.

Ergonomic and performance analysis of rail-type boom sprayer for agro-photovoltaic power system

  • Rack-Woo Kim;Jae-Woong Han;Woong Kim
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.1
    • /
    • pp.151-162
    • /
    • 2022
  • This study was conducted to develop a rail-type boom sprayer, performing safe spraying with improved ergonomic postures during pesticide spraying of agro-photovoltaic power system. The sprayer was designed to reduce labor cost and to be safe from pesticide exposure, and was analyzed through a comparison with a conventional spray method. The rail-type boom sprayer, consisted of a self-propelled spray and hose winder, hose, and boom sprayer parts, was designed to automatically pull and spray in the vertical and horizontal directions. The performance of the sprayer for an agro-photovoltaic power system was appropriate. From the analysis of postures with the Ovako Working posture Analysis System (OWAS), Rapid Entire Body Assessment (REBA), and Rapid Upper Limb Assessment (RULA) methods, the musculoskeletal risk factors to the body using the rail-type boom sprayer were less than those with the conventional power sprayer. In addition, the possibility of pesticide poisoning was reduced compared to the conventional power sprayer. The working capacity with the rail-type boom sprayer was more than five times greater, compared with the conventional power sprayer. After performing pesticide spraying with the rail-type boom sprayer, the labor cost was reduced to 42,750 won·yr-1, which was 90% (402,750 won·yr-1) less than the cost with the use of a conventional power sprayer (445,500 won·yr-1).

Assessment of Radionuclide Deposition on Korean Urban Residential Area

  • Lee, Joeun;Han, Moon Hee;Kim, Eun Han;Lee, Cheol Woo;Jeong, Hae Sun
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.101-107
    • /
    • 2020
  • Background: An important lesson learned from the Fukushima accident is that the transition to the mid- and long-term phases from the emergency-response phase requires less than a year, which is not very long. It is necessary to know how much radioactive material has been deposited in an urban area to establish mid- and long-term countermeasures after a radioactive accident. Therefore, an urban deposition model that can indicate the site-specific characteristics must be developed. Materials and Methods: In this study, the generalized urban deposition velocity and the subsequent variation in radionuclide contamination were estimated based on the characteristics of the Korean urban environment. Furthermore, the application of the obtained generalized deposition velocity in a hypothetical scenario was investigated. Results and Discussion: The generalized deposition velocities of 137Cs, 106Ru, and 131I for each residence type were obtained using three-dimensional (3D) modeling. For all residence types, the deposition velocities of 131I are greater than those of 106Ru and 137Cs. In addition, we calculated the generalized deposition velocities for each residential types. Iodine was the most deposited nuclide during initial deposition. However, the concentration of iodine in urban environment drastically decreases owing to its relatively shorter half-life than 106Ru and 137Cs. Furthermore, the amount of radioactive material deposited in nonresidential areas, especially in parks and schools, is more than that deposited in residential areas. Conclusion: In this study, the generalized urban deposition velocities and the subsequent deposition changes were estimated for the Korean urban environment. The 3D modeling was performed for each type of urban residential area, and the average deposition velocity was obtained and applied to a hypothetical accident. Based on the estimated deposition velocities, the decision-making systems can be improved for responding to radioactive contamination in urban areas. Furthermore, this study can be useful to predict the radiological dose in case of large-scale urban contamination and can support decision-making for long-term measurement after nuclear accident.

Transdermal Permeation-enhancing Activities of some Inorganic Anions

  • Ko, Young-Il;Kim, Sung-Su;Han, Suk-Kyu
    • Archives of Pharmacal Research
    • /
    • v.18 no.4
    • /
    • pp.231-236
    • /
    • 1995
  • Effects of sodium salts of various monovalent inorganic anions on transdermal permeation of salicylic acid were investigated. In in-vitro experiment using a Franz-type diffusion cell and excisicylic acid were investigated. In-vitro experiment using a Franze-type diffusion cell and excised mouse skin, the permeation-enhancing activities of the sodium salts of inoraganic anions were rougly proportional to lyotropic Hofmeister serlling abilities of the anions l F/sup -/

  • PDF

Quantitative analysis of myxosporean parasites (Enteromyxum leei and Parvicapsula anisocaudata) detected from emaciated olive flounder (Paralichthys olivaceus) and rearing water (여윔증상 넙치 및 사육수 내 검출된 점액포자충(Enteromyxum leei and Parvicapsula anisocaudata)의 정량적 분석)

  • Lee, Young Juhn;Jun, Lyu Jin;Kim, Ye Ji;Han, Ji Eun;Lee, Eung Jun;Jeong, Joon Bum
    • Journal of fish pathology
    • /
    • v.34 no.2
    • /
    • pp.161-168
    • /
    • 2021
  • Quantitative analysis of myxosporean parasites (Enteromyxum leei and Parvicapsula anisocaudata) were performed using real-time PCR on the internal organs (head kidney, body kidney, intestine, spleen, brain, liver, heart, muscle, blood, and eye) of emaciated Paralichthys olivaceus from farm-A. The highest DNA copy number of E. leei was shown in the intestine (1.3 × 108 copies/mg tissue) of emaciatied P. olivaceus and DNA copy number in the other internal organs (1.3 × 103~4.6 × 105 copies/mg tissue) showed lower than in intestine. From the result of real-time PCR for P. anisocaudata, it was considered mildly infected, due to the low DNA copy numbers of the head kidney (1.3 × 103 copies/mg tissue) and body kidney (9.1 × 103 copies/mg tissue). In order to investigate whether myxosporean parasites can be detected in a non-invasive way, quantitative analysis of E. leei and P. anisocaudata from rearing water of three farms were performed by real-time PCR. The DNA copy number of E. leei from rearing water of farm-A and farm-B were 8 × 104 and 5 × 105 copies/L, respectively. However, it was not detected in farm-C. For P. anisocaudata from rearing water, farm-A, farm-B and farm-C showed 0, 2.0 × 106 and 5.1 × 106 copies/L, respectively.

Comparison of tolerance of red seabream, Pagrus major exposed to hypoxia with body size (저산소에 노출된 참돔(Pagrus major)의 개체 크기에 따른 내성 비교)

  • Ji-Do Han;Heung-Yun Kim
    • Journal of fish pathology
    • /
    • v.36 no.2
    • /
    • pp.379-388
    • /
    • 2023
  • Experiments were performed to investigate hypoxia tolerance with body size of red seabream (Pagrus major) at 24℃. The rate of oxygen consumption was measured at an interval of 10 min using automated intermittent-flow respirometry. The weight-specific standard metabolic rate (SMR, mg O2 kg-1hr-1) and critical oxygen saturation (Scrit, % air saturation) of the fish were measured under normoxic condition and progressive hypoxia with 0.6-786 g of fish weight (W), respectively. SMR typically decreased with increasing body weight based on SMR=351.59·W-0.195 (r2=0.934). Scrit was higher in larger fish than those of smaller fish in the range of 17.3-24.4%. The result of this study suggests that the smaller seabream can withstand in hypoxic waters better than the larger ones.

Tb3+ and Ce3+ Intercalated Laponite Powder: The Influence of Ce3+ Ions on Thermal Stability and Optical Properties of Tb3+ Intercalated Laponite

  • Lee, Han-Na;Kim, You-Hyuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1273-1276
    • /
    • 2011
  • Laponite samples intercalated with $Tb^{3+}$ or $Tb^{3+},Ce^{3+}$ ions were prepared by exchange of Na+ ions in interlayers with $Tb^{3+}$ or $Ce^{3+}$ ions. Strong green and weak blue emissions under vacuum ultraviolet (VUV) excitation (${\lambda}$ = 158 nm) were observed due to the $^5D_4{\rightarrow}^7F_J$ and $^5D_3{\rightarrow}^7F_J$ emission lines, respectively. $Tb^{3+}$ ions in an interlayer of laponite mainly existed in ion pairs or clusters, as evidenced by the concentration-dependent luminescence of the $Tb^{3+}$ ions on the relative intensities of the $^5D_3{\rightarrow}^7F_J$ and the $^5D_4{\rightarrow}^7F_J$ emission lines, due to the action of a cross-relaxation process. The addition of $Ce^{3+}$ ions increased the thermal stability of $Tb^{3+}$ intercalated laponite up to $650^{\circ}C$ and quenched the $^5D_3{\rightarrow}^7F_J$ emission lines, probably by promoting the formation of $Tb^{3+}$ ion pairs at relatively low $Tb^{3+}$ concentrations.

Literature review on the job competency of paramedics and paramedic students in Korea (국내 응급구조사 및 응급구조학과 학생의 직무역량 관련 연구에 대한 문헌고찰)

  • Min-Ju Kang;Keun-Young Kim;Hye-Jin Seo;Seung-Tae Han
    • The Korean Journal of Emergency Medical Services
    • /
    • v.27 no.2
    • /
    • pp.41-50
    • /
    • 2023
  • Purpose: This study aimed to identify research trends related to the job competency of paramedics and paramedic students in Korea. It also presents further research directions. Methods: Papers from three databases (RISS, KISS, and DBpia) were reviewed. The keywords were 'paramedi* and competency,' 'paramedi* and job competency,' 'paramedi* and student and competency,' and 'paramedi* and student and job competency.' No limit was imposed on the research period. Four researchers conducted the inclusion and exclusion processes. Differences in opinion were resolved through sufficient discussion. Results: Twelve studies were selected for review, of which 11 were descriptive survey research studies and 1 was quasi-experimental. Eight studies aimed to determine the current level of competency, and three aimed to identify competency. The remaining study was designed for the development of and application in competency-related programs. The subject of most studies was competency during disasters. Conclusion: Based on these results, future research on paramedic job competency should include a wider variety of methods and subjects.

Comparison of applicability of HVAC and air cleaners in a subway station platform against airborne infection of SARS-CoV-2 (지하역사 승강장에서 코로나19 바이러스 공기감염 대응 공기조화기와 공기청정기의 적용 효과 비교)

  • Lee, Gunhee;Kim, Sang Bok;Park, Inyong;Hong, Kee Jung;Lee, Yeawan;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2022
  • In this work, virion concentration and its dose changes by HVAC and air cleaners were estimated in a subway station platform to control airborne infection of SARS-CoV-2. Collection efficiencies with particle size were measured for the air filter equipped in a HVAC in one subway station in Daejeon. Indoor PM2.5 changes according to outdoor PM2.5 with time were also measured to estimate air infiltration rate in the subway station platform. When infected persons generate virions by 104, 105, 106, 3 × 106 and 5 × 106 h-1 in a 2,400 m3 volume platform, the concentration and dose were estimated as 9, 92, 275 and 458 virions/m3 and 4, 43, 130 and 217 virions after 1 hour exposure, respectively. The concentration and dose were reduced by 70%, and 64%, respectively by operations of both HVAC (with a flow rate of 16,000 m3/h, MERV 11) and ten air cleaners(with total CADR 10,740 m3/h) compared to those without operation of both HVAC and air cleaners. However, virion dose in the platform was estimated to be too low at the general conditions due to a large space, a high air infiltration (3 h-1) and a short residence time (usually < 10 mins) in the platform irrespective of the operations of HVAC or air cleaners. HVAC with filters and air cleaners would be more necessary in the concourse or shopping areas in the subway stations to reduce the infection dose from a few hundred to several tens virions in a hour.