• 제목/요약/키워드: Kim test

검색결과 52,850건 처리시간 0.082초

헬리콥터 로터 블레이드의 기본 물리량 및 비회전 동특성 시험 (Basic Properties Test and Non-rotating Dynamic Test of Helicopter Rotor)

  • 윤철용;김태주;기영중;심헌수;김승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.103-108
    • /
    • 2013
  • This paper describes basic properties tests and non-rotating dynamic test for rotor blade, flexbeam, and torque tube of which bearingless rotor in helicopter consists. A basic properties test are bending and twist test to find the flap stiffness, lag stiffness, and twist stiffness of specimens. The purpose of dynamic test is to find natural frequencies and modes in non-rotating state. The test results are used to update the analysis model. The updated analysis results using rotorcraft comprehensive code match the tests quite well. The updated model input based on the tests will be utilized to analysis the conditions of rotating whirl tower test before the whirl test and will be compared with the whirl tower test results.

  • PDF

765kV급 송전선로 공기절연거리 설정을 위한 시험전극의 섬락전압 특성 (The Flashover Characteristics of Test Electrodes against Clearance of Air Insulation for 765kV Transmission Line)

  • 김윤택;김영배;이형호;김정문;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1337-1340
    • /
    • 1995
  • For the purpose of rational design of air insulation, it is need to experiment with similar to real shape test object and conform the characterisics. But basic distances of air insulation of transmission line, tower, etc. can be acquired from flashover characteristic of rod-rod, rod-plane electrodes. In this paper, before field test of 765kV transmission line for determination of distances of phase to ground insulation, we execute lightning, switching impulse test with test electrod(rod-rod, rod-plane) against clearances of air insulation. Each tests use up-down method and consist of 30 times flashover test. Flashover data treatment program and air correction program following IEC 60-1(1987) standard were completely builted.

  • PDF

대용량 사이리스터 특성평가 장비의 설계 및 제작 (Design of Characteristics Test Equipment for a Large Capacity Thyristor)

  • 서길수;김형우;김기현;김남균;김은동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.567-572
    • /
    • 2005
  • Recently, application area of the thyristor is extends to power conversion systems, such as HVDC, BTB, SVC and FACTS. Therefore, reliability diagnostic technique on thyristor is needed to obtain stability and maintenance of power conversion systems. To measure the characteristics of the thyristor, test equipments which based on IEC 747-6 and KS C 7023 standard are needed. In this paper, we presents the design and manufacture of the test equipments for 6.5kV/4.2kA thyristor which used in thyristor valve of HVDC conversion systems by using test standard. Voltage, current, dv/dt and turn-off time test equipments were designed and manufactured. Each systems were made separately, but unity operation can possible.

재형상 비행제어 시스템의 비행시험 결과 분석 (Analysis on Flight Test Results of Reconfiguration Flight Control System)

  • 민병문;김성필;김봉주;김응태;탁민제
    • 제어로봇시스템학회논문지
    • /
    • 제14권12호
    • /
    • pp.1244-1252
    • /
    • 2008
  • This paper presents the analysis results obtained by the flight test of reconfiguration flight control system for an aircraft. The reconfiguration flight control system was designed by using control allocation scheme that automatically distributes the demanded control moments determined by control law to each actual control surface. In this paper, some control allocation algorithms for reconfiguration control of general aircraft with redundant control surfaces are summarized and their performance evaluation results through nonlinear simulation and Hardware-In-the-Loop-Simulation (HILS) test are shown. Also, Unmanned Aerial Vehicle (UAV) system adopted as a platform for the flight test of reconfiguration flight controller and the implementation procedure of reconfiguration flight controller into real-time UAV system were introduced. Finally, flight test results were analyzed.

실어증 선별검사 도구개발을 위한 예비연구 (A Preliminary Study for Development of the Aphasia Screening Test)

  • 김향희;이현정;김덕용;허지회;김용욱
    • 음성과학
    • /
    • 제13권2호
    • /
    • pp.7-18
    • /
    • 2006
  • An aphasia screening test can serve a main purpose of differentiating aphasics from non-aphasic patients in a quick as well as efficient manner. As a preliminary study for developing a standardized aphasia screening test for Korean patients, we constructed an aphasia screening test constituting items from the Paradise' Korean version-the Western Aphasia Battery(P K-WAB). All test items were analyzed in order to extract items with optimal item discrimination and adequate item difficulty indices. From the results, we were able to select some items from each subtest with optimal results of discriminant function analysis for aphasic and normal control groups. It is expected, thus, that information on the item analysis could be utilized in developing a Korean aphasia screening test.

  • PDF

단락시험에서 후비보호차단기와 투입스위치의 중요 역할 (The study of a primary role of Back up Breaker and Making Switch for Short Circuit Test)

  • 김선구;김선호;김원만;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.915-916
    • /
    • 2007
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, Exciter, CLR, Back Up Breaker, Making Switch and TRV etc. Especially Back up Breaker and Making Switch are very important equipments to test the short circuit test. A role of a Back up Breaker is to break high-voltage and high-current for short circuit test and a Making Switch should be operated always same speed/time and kept electrical-mechanical characteristics to make the voltage and current of short circuit test. This study introduces to the short circuit test also to kinds, principal movements and compare them of Back up Breaker and Making Switch.

  • PDF

PVA 시멘트 혼합토의 공학적 특성 연구 (A Study on the Engineering Characteristics of PVA (Polyvinyl Alcohol) Fiber-Cement-Soil Mixtures)

  • 김영익;연규석;김기성;유경완;김용성
    • 한국농공학회논문집
    • /
    • 제53권2호
    • /
    • pp.35-43
    • /
    • 2011
  • This study aimed to investigate the engineering characteristics of PVA fiber-cement-soil mixture used to prevent or reduce brittle failure of cement-soil mixtures due to the tensile strength increase from the addition of a synthetic fiber. The engineering characteristics of PVA fiber-cement-soil mixtures composed of PVA fiber, soil, and a small amount of cement was analysed on the basis of the compaction test, the unconfined compression test, the tensile strength test, the freezing and thawing test, and the wetting and drying test. The specimens were manufactured with soil, cement and PVA fiber. The cement contents was 2, 4, 6, 8, and 10%, and the fiber contents was 0.4, 0.6, 0.8, and 1.0% by the weight of total dry soil. To investigate the strength characteristics depending on age, each specimen was manufactured after curing at constant temperature and humidity room for 3, 7 and 28 days, after which the engineering characteristics of PVA fiber-cement-soil mixtures were investigated using the unconfined compression test, the tensile strength test, the freezing and thawing test, and the wetting and drying test. The basic data were presented for the application of PVA fiber-cement-soil mixtures as construction materials.

자체구동롤러 컨베이어의 신뢰성 평가기준 (Reliability Assessment Criteria of Motorized Roller Conveyor)

  • 김영주;고희양;한인섭;김용수
    • 한국생산제조학회지
    • /
    • 제24권5호
    • /
    • pp.521-529
    • /
    • 2015
  • Owing to a reliance on imported products from Europe and Japan, the use of logistics equipment with poor energy efficiency coupled with high maintenance costs can lead to high operating costs for some domestic logistic centers. To lower their operating costs, the logistic centers use motorized roller conveyors. In order to commercialize this process, it is necessary to establish the test criteria and assess the reliability of the process. Currently, there exists no standard verification method to test the reliability of motorized roller conveyors. In this study, we propose reliability assessment criteria for a: i) reliability test, ii) environmental test, iii) safety test, and iv) lifetime test.

대용량(50kA)의 Making Switch와 Back Up Breaker 접점 개발에 따른 검증시험의 연구 (The Study of the Verification Test for Development of Contacts(50kA) of Making Switch and Back Up Breaker)

  • 김선구;김원만;나대열;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.842-844
    • /
    • 2004
  • The Back Up Breaker and Making Switch are very important equipments for the short circuit test facility, and contacts are the most important parts of the above switches. There are very many kind of contacts according to switches characteristic and should be done the verification test before use, especially development contacts. This study describes the class of switches, arc chute, material of whole contacts and essential test for verification. The essential test for verification are dielectric test, mechanical operation test, short-time withstand current test, load current breaking test, and short-circuit making current test etc.

  • PDF