• Title/Summary/Keyword: KS Certification

Search Result 64, Processing Time 0.022 seconds

A Study on the Evaluation of Uncertainty of Rockwell Hardness C Scale According to the Korean Industrial Standards(KS) (한국산업표준(KS)에 따른 로크웰 경도 시험기의 불확도 산정에 관한 연구)

  • Bahng, G.W.;Tak, Nae-Hyung
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.3
    • /
    • pp.163-169
    • /
    • 2000
  • Recently, uncertainty of hardeness became a major concem for the people working on the laboratory evaluation and accreditation. It is required to indicate uncertainty of hardness tester on the report after calibration. In addition to this, uncertainty of certified hardness reference block is also required to indicate on the certification sheet. Method on the evaluation of uncertainty in hardness measurement is agreed only recently for Rockwell hardness C scale. In this paper, a preliminary calculation of uncertainty based on type B evaluation has been made for hardness testers which satisfies the requirements of Korean Standards. It was found that the tolerance limit of mean value specified in KS should be increased to be compatible with the calculated uncertainty.

  • PDF

A Study on the Integrated Management Systems Establishment and Operation of the KS, QMS and EMS (KS, QMS, EMS 통합경영시스템 구축 및 운영에 관한 연구)

  • Kim, Kwang-Soo;Lee, Sang-Hun;Chung, Sun-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.175-189
    • /
    • 2010
  • With the foundation of the WTO in 1995, the era of boundless and unlimited competition between many of the countries around the world has begun. In order to elevate the competitiveness in the international market, we have incorporated the QMS and the EMS system, establish by the International Standardization Organization, and the process has been operated under the authorization. However, many Korea companies' separate enforcement of the QMS and the EMS system is causing the dissipation of the labor force and the invested capital. As we can see through studying the contents on this paper, the number of documents has been reduced down to 54% (From 139 of them to 64 of them), and the conflict and the chaos that could have happened between the documents has been prevented. Its' outcome is attributed to the foundation and the embarkation on the Integrated Management Systems of the KS, QMS, and EMS. Not only that, it has also reduced the waste elements up to greater than 40%.

  • PDF

A Study on the Integrated Management Systems Establishment and Operation of the KS, QMS and EMS (KS, QMS, EMS 통합경영시스템 구축 및 운영에 관한 연구)

  • Kim, Kwang-Soo;Lee, Sang-Hun;Chung, Sun-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.229-238
    • /
    • 2010
  • With the foundation of the WTO in 1995, the era of boundless and unlimited competition between many of the countries around the world has begun. In order to elevate the competitiveness in the international market, we have incorporated the QMS and the EMS system, establish by the International Standardization Organization, and the process has been operated under the authorization. However, many Korea companies' separate enforcement of the QMS and the EMS system is causing the dissipation of the labor force and the invested capital. As we can see through studying the contents on this paper, the number of documents has been reduced down to 54% (From 139 of them to 64 of them), and the conflict and the chaos that could have happened between the documents has been prevented. Its' outcome is attributed to the foundation and the embarkation on the Integrated Management Systems of the KS, QMS, and EMS. Not only that, it has also reduced the waste elements up to greater than 40%.

A Study on Floor Slip Resistance Standard and Test Method for BF Certification (BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구)

  • Shin, Dong-Hong;Seong, Ki-Chang;Park, Kwang-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.

A Survey on the Perception of Agricultural Food Accreditation and Traditional Food Quality Certification (농식품 인증 및 전통식품 품질인증에 관한 인식조사)

  • Huh, Jung-In;Jin, So-Yeon
    • Journal of the Korean Society of Food Culture
    • /
    • v.26 no.3
    • /
    • pp.220-229
    • /
    • 2011
  • This study attempted to understand the perception and the degree of trust that consumers had in the national agricultural food accreditation system, to inquire into and examine the consumers' perception of traditional food quality certification performed for the protection of excellent traditional food, and to propose the right direction for the policies on the traditional food quality certification system and the plans to improve consumers' perception of the system. According to the results of this survey performed in married women, based on the 'the recognition of accreditation system' and 'the recognition of certification marks' of 'the seventh national agricultural food accreditation system' presently being used by the Ministry for Food, Agriculture, Forestry and Fisheries, the household food purchasers showed high recognition for eco-friendly agricultural product accreditation, processed food KS certification, and organically processed food certification in that order. Meanwhile, it was shown that they indicated low recognition for the traditional food-related accreditation systems such as 'traditional food quality certification' and 'food grand master'. It was found that reliability of the certification mark provided by the agricultural food accreditation system gained 3.54 points (on a 5-point scale), and 68.1% of the study subjects referred to the certification marks while purchasing agricultural foods. And most of them answered to the question of 'why they referred to the certification marks' saying that it was done 'to choose safe food'. The most frequent answer to question of 'the means to recognize the traditional food quality certification system' was 'broadcasting, advertising'. 57.3% of the subjects had a previous experience of buying a product certified by the traditional food quality certification system, and 93.2% of all the subjects had the intention to buy a product certified by the traditional food quality certification system later. And most of them answered that 'strengthening government policies' would be the most ideal way to inform the public of the traditional food quality certification system. According to the results of this study, while 'relying on the traditional food quality certification system in general' was relatively high among the consumers, 'intention to buy quality certified products by visiting a distantly located store' was low; thus, from this analysis, it can be seen that there is a need for diversification of places selling these quality certified products and to establish a distribution network for these products.

A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size (창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석)

  • Kim, Seong-Beom;Lee, Su-Yeul;Kim, Dong-Yoon;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

Analysis of Electrical Characteristics of CCFL Exit Light (CCFL유도등의 전기적 특성 분석)

  • Jung, Jong-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.184-193
    • /
    • 2021
  • Purpose: In this study, since the operation principle of the CCFL Exit light is the same as that of general lighting equipment, the characteristics of the CCFL Exit light were analyzed by deriving test items that can affect the characteristics of the light source from the KS standard, which is the standard for lamp ballast performance certification of general lighting equipment. Method: The samples used in the experiment were performed on products of two manufacturers for each size, such as large, medium, and small, and the test items were power factor, crest factor, and current harmonic distortion. Result: As a result of the experiment, the power factor showed a value between 0.4 and 0.6 in all samples, which was smaller than the 0.9 value set by KS. The crest factor ranged from 3.6 to 3.7 for large, 4.4 to 4.7 for medium, and 3.5 to 3.7 for small. It showed a value more than two times higher than the KS standard of 1.7. Current total harmonic distortion ranged from 81% to 110%, and considering that the KS standard was less than 20%, it could be confirmed that all samples had a value significantly exceeding the KS standard. Conclusion: The crest factor and current total harmonic distortion may affect the temperature rise of the light source and the burnout of the device. When developing an exit light, if this item is developed within the scope of the KS standard, the quality improvement and maintenance of the exit light will be greatly improved.

Research on Functionality Extension of Certification System for High Speed Power Line Communication Device based on KS ${\times}$ 4600-1 Class A (KS ${\times}$ 4600-1 고속전력선통신 클래스 A 장치 인증 시험 시스템의 기능 확장에 대한 연구)

  • Na, Eun-Chong;Kim, Dong-Ha;Lee, Sung-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06d
    • /
    • pp.415-417
    • /
    • 2012
  • 최근 간단한 연결방식과 손쉬운 네트워크의 구축이 가능하고 무선 통신에서의 음영지역 해소 등의 이유로 홈 네트워크와 스마트 그리드를 구축하는데 용이한 전력선통신이 주목받고 있다. 이에 본 논문에서는 옥내 또는 옥외에서의 고속전력선통신에 대해서 서술하고 이더넷 인터페이스를 통한 고속전력선통신 Class A 기준장치의 MAC 계층 적합성 및 상호운용성을 시험하고 이를 위한 통합 프로그램의 개발 및 보완을 수행하였다.

An Study KS Standardization for Acoustic noise measurement of the Wind Turbine (풍력발전시스템 소음평가의 KS 규격화에 관한 연구)

  • Son, C.Y.;Kim, J.H.;Oh, D.H.;Park, J.B.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.406-410
    • /
    • 2005
  • The wind turbine, Europe and the United States are different with the standards process each other when the manufacturing company which in order to demand the standards process to a construction in the multi country with interested parties of the corresponding nation to, always the re-agreement is difficult. Korean wind turbine also detail there is not a standard, when it produces and establishes of wind turbine, the problem point occurs. It is like that investigation of international standards system it leads and when it prepares the Acoustic noise measurement of the Wind Turbine Systems of Korea, it prepares the base for industrial development wind turbine of Korea.

  • PDF

Design and Implementation of a ZigBee Nework-based Integrated AFCI (지그비 네트워크 기반 복합형 AFCI 설계 및 구현)

  • Chang, Ki-Heung;Kim, Kee-Min;Kim, Jae-O;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.41-48
    • /
    • 2010
  • In this paper, a new type of integrated AFCI is designed and implemented by combining individual circuit breaker characteristics, which can effectively detect arc fault signals in real-time. The proposed integrated AFCI satisfies the UL1699, the USA certification standard, and the Korean circuit breaker standards such as KS C4613 and KS C8321. Data signals are transferred to the management server via ZigBee network to analyze dangerous factors and to prevent unwanted trip. It is also shown by experiments that arc fault signals are detected and analyzed by using the integrated AFCI with ZigBee networks.