• Title/Summary/Keyword: KS (Korea Standard)

Search Result 424, Processing Time 0.028 seconds

Utilization of Mine failings from the Jeonju-Il Mine (전주일(全州一) 금속광산(金屬鑛山) 폐광미(廢鑛尾)의 활용(活用) 방안(方案) 연구(硏究))

  • Jeong, Soo-Bok;Chae, Yeung-Bae;Hyun, Jong-Yeong;Kim, Hyung-Seok;Yoon, Sung-Moon
    • Resources Recycling
    • /
    • v.16 no.1 s.75
    • /
    • pp.44-53
    • /
    • 2007
  • The Jeonju-Il mine tailings contain large quantities of $SiO_2\;and\;Al_2O_3$ and lesser quantities of metallic components. In this study, we studied about the possibility of using mine tailings as a raw material in various industries. it was found that the sintered mine tailings had a good quality in every respect such as chromaticity, firing shrinkage and water absorption etc. Therefore if can substitute clay mineral in the ceramic industry. Also it can substitute about 2.94% of the raw materials of ordinary portland cement. We can use the coarse tailing as the fine aggregate for the ready-mixed mortar; and the fine tailing, as the filler for the bituminous paving mixture; because both products were not only suitable for Korea industrial standard in quality, but also environmentally harmless.

Comparison on Color Preference of BRICs Consumers (BRICs 지역 소비자 색채선호 비교)

  • Choi Mi-Young;Shim Young-Wan;Syn Hye-Young
    • Journal of the Korean Society of Costume
    • /
    • v.56 no.5 s.104
    • /
    • pp.118-131
    • /
    • 2006
  • Color is one of the most effective factor in visual aspect influencing consumer's choice. However, the color preference varies as time passes, society changes, new culture develops, that is variable in its nature. And the underlying meaning or accompanying color image differs in every area. We believe the study on the color preference is meaningful, especially on BRICs market, recently gathering attentions for their market competitiveness and growth potential. For this research, data collected from 5 countries(including Korea) by 1:1 interview during 3 weeks in Aug. 2005. Usable data from 923 adult urban residents were used for final data analysis. Color chart for research was categorized by using COS Color System into KS standard color 10grades plus 1 neutral, with 5 grades of tones. Through this empirical study, the data were analyzed by mean, ANOVA, Duncan-test of SPSS Win(ver.10.0). The result generated from this study are as follows : First, analysis through hue & tone system reveals that preference on principle colors (R, Y, G, B, P) is higher than intermediate colors and pale, light, vivid tones were preferred to dare and deep tones. Second, personal color preference is reflected in color preference in fashion items. Thus, we may conclude color preference in fashion item largely influenced by country characteristics. Third, biggest difference by country from hue analysis are neutral and PB colors. Neutral, widely preferred color in every county, more preferred in India, Russia, Brazil than China. We expect this result can be utilized as a basic material for developing BRICs market.

A Study of Factors Affecting the Grid-test (X선격자 성능시험에 미치는 인자의 검토)

  • Lee, In-Ja;Shin, Wha-Soo;Kim, Chang-Kyun;Huh, Joon;Kang, Hong-Seok;Park, Jun-Chul;Yoon, Chul-Ho
    • Journal of radiological science and technology
    • /
    • v.10 no.1
    • /
    • pp.61-67
    • /
    • 1987
  • Authors tested the grid functions with various thickness of acryl phantom, radiation field size and diameter of shielding lead. The results are as followed: 1. The characteristic values of grid are affected by phantom thickness, but free from radiation field size in the diagnostic useful range. 2. The quantity of scattered radiation was decreased according to the diameter of shielding lead under 20mm, and then the diameter the smaller the better, in accordance with proposed KS standard. 3. The quantity of primary radiation was increased a little at the 80mm diameter radiation field size, but did not have much differences. Therefore, it was thought that it is needed to limit beam size in case of absolute values in accordance with any standards, but it has no matter to use 100 mm diameter in case of relative values just to campare with.

  • PDF

Performance of KICT-type Large Penetration Test (LPT) (한국형 대형관입시험 장비의 개발 및 현장 적용성 평가)

  • Kim, Young-Seok;Kim, Young-Chin;Hong, Sung-Wan;Kang, Jae-Mo;Ji, Wan-Goo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.603-610
    • /
    • 2007
  • It is well known that the standard penetration test (SPT) has been used in all over the world to get geotechnical properties of the ground. However, it is difficult to apply the SPT to the dense sand, gravel, weathered rock, etc. For the application of the SPT in these grounds, it is necessary to change in the diameter and the impact energy of the SPT. For the improvement of site investigation technology, Large Penetration Testing device (KICT-type LPT) was developed and applied to the in situ condition. The drop height and weight of the hammer in developed system were decided as 760 mm and 150 kg, respectively. Semi-auto hammer drop system identical with KS F2307 and JI A1259S was adopted. And the developed sampler has the inner diameter of 63 mm and the length of 500 mm with the adjustment of energy ratio to the SPT of 1.5. The hammer energy level was measured during the performance of the KICT-type LPT using SPI system (quality control system from driven piles).

  • PDF

The Failure Analysis of Double Pipe for Insulation Used Power Plant by Grooving Corrosion (발전소용 이중보온용 강관의 홈부식(Grooving Corrosion)에 의한 파손 분석)

  • Ham, Jong-Oh;Park, Ki-Duck;Park, Sung-Jin;Sun, Il-Sik
    • Journal of Applied Reliability
    • /
    • v.15 no.3
    • /
    • pp.197-206
    • /
    • 2015
  • Failure analysis of pre-insulated pipe (SPPS 380, 400A) transporting high temperature water ($95{\sim}110^{\circ}C$) for a plant was carried out. The damaged area (${\Phi}5mm$) of pre-insulated pipe was found only on welds. The chemical composition of damaged pipe meets specification of carbon steel pipes for pressure service (KS D 3562). As results of microstructure analysis, crack propagated from outer to inside after pitting corrosion occurred on the outside surface. The non-metallic inclusion existed on the end of crack. And the non-metallic inclusion continuously and linearly formed along with the bond line of welds. Based on SEM-EDS analysis, the nonmetallic inclusions have higher Manganese (Mn) and Oxygen (O) content but sulfur (S) was not detected. As results of water quality analysis, hydrogen ion concentration and minerals like Fe, Mg, Si were in low level. But the content of dissolved oxygen (11.2 ppm) was slightly higher than that of standard. It seems that the cause of damaged pipe is grooving corrosion due to MnO inclusion formed on bond line and corrosion took place nearby welds.

Decay Resistance and Anti-mold Efficacy of Wood Treated with Fire Retardants (난연처리 목재의 방미 및 방부성능)

  • Son, Dong Won;Kang, Mee Ran;Lee, Dong-Heub;Park, Sang-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.559-565
    • /
    • 2013
  • This study evaluated the ability of white and brown rot fungi to decompose fire retardant-treated wood by measuring mass loss. Anti efficacy of FRT against sapstain and mold fungi was evaluated. Wood was treated with liquid sodium silicate and boric acid, ammonium borate, di-ammonium phosphate. Retardant treated wood was then subjected to fungal decay resistance tests performed according to KS standard method using a brown-rot fungus, Fomitopsis palustris and white rot fungus Trametes versicolor. Aspergillus niger, Penicillium funiculosum, Rhizopus nigricans, Aureobasidium pullulans, Tricoderma virede fungi were used anti-sapstain and mold test. Boron and phosphorus chemicals used in this study increased the resistance of fire retardant treated wood against both fungal attack. Anti mold and sapstain efficacy of the fire retardant treated wood was excellent but there were difference depend on mold. After the liquid sodium silicate treatment, the second chemical treatment process could lead chemical fixation into wood, which effects decay resistance.

Emission Characteristics of Fine Particles from Thermal Power Plants (화력발전소의 미세먼지 배출특성)

  • Park, Sooman;Lee, Gayoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.455-460
    • /
    • 2020
  • In order to identify the characteristics of fine particle emissions from thermal power plants, this study conducted measurement of the primary emission concentration of TPM, PM10 and PM2.5 according to Korea standard test method (ES 01301.1) and ISO 23210 method (KS I ISO 23210). Particulate matters were sampled in total 74 units of power plants such as 59 units of coal-fired power plants, 7 units of heavy oil power plants, 2 units of biomass power plant, and 6 units of liquid natural gas power plants. The average concentration of TPM, PM10, PM2.5 by fuel are 3.33 mg/m3, 3.01 mg/m3, 2.70 mg/m3 in coal-fired plant, 3.02 mg/m3, 2.99 mg/m3, 2.93 mg/m3 in heavy oil plant, 0.114 mg/m3, 0.046 mg/m3, 0.036 mg/m3 in LNG plant, respectively. These results of TPM, PM10 and PM2.5 were satisfied with the standards of fine dust emission allowance in all units of power plants, respectively. Also, this study evaluated the characteristics of fine particle emissions by conditions of power plants including generation sources, boiler types and operation years and calculated emission factors and then evaluated fine particle emissions by sources of electricity generation.

Development of an Oraganic-Inorganic Hybrid Coating Solution for Improvement in Flame Retardant Properties of Wallpapers (벽지의 방염특성을 개선하기 위한 유-무기 하이브리드 코팅 용액 개발)

  • Jeong, Gyu Jin;Kang, Tae Wook;Kim, Jin Ho;Kim, Bong Man;Seo, Eun Kyung;Bae, Byungseo;Kim, Sun Woog
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.178-183
    • /
    • 2022
  • For enhancing the flame-retardant properties of wallpapers, we developed an organic-inorganic hybrid solution with ZrSiO4 as a functional ceramic powder, coated on non-woven fabric using dip coating, spray coating, and slot-die coating methods. Their flame retardant properties were characterized by a 45° combustion tester, which is manufactured according to the flame-retardant performance standard (KOFEIS 1001 and KS F 2819). In organic-inorganic hybrid solution, with increasing the concentration of acid-catalyst (acetic acid), the precipitation of ZrSiO4 powders increased, and the flame retardant properties decreased. The highest flame retardant result was obtained for the solution adding 5 wt% acetic acid. The optimization of the coating method and coating number resulted in the most excellent flame-retardant properties being obtained for the non-woven fabric coated for 5 or 7 times by dip coating method, and their flame-retardant properties corresponded to class 2 flame-retardant performance of wallpapers.

A Study on the Safety of Carbon Manufacturing By-product Gas Emissions (카본제조 부생가스 배출 안전성에 관한 연구)

  • Joo, Jong-Yul;Jeong Phil-Hoon;Kim, Sang-Gil;Sung-Eun, Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.99-106
    • /
    • 2024
  • In the event of an emergency such as facility shutdown during process operation, the by-product gas must be urgently discharged to the vent stack to prevent leakage, fire, and explosion. At this time, the explosion drop value of the released by-product gas is calculated using ISO 10156 formula, which is 27.7 vol%. Therefore, it does not correspond to flammable gas because it is less than 13% of the explosion drop value, which is the standard for flammable gas defined by the Occupational Safety and Health Act, and since the explosion drop value is high, it can be seen that the risk of fire explosion is low even if it is discharged urgently with the vent stock. As a result of calculating the range of explosion hazard sites for hydrogen gas discharged to the Bent Stack according to KS C IEC 60079-10-1, 23 meters were calculated. Since hydrogen is lighter than air, electromechanical devices should not be installed within 23 meters of the upper portion of the Bent Stack, and if it is not possible, an explosion-proof electromechanical device suitable for type 1 of dangerous place should be installed. In addition, the height of the stack should be at least 5 meters so that the diffusion of by-product gas is facilitated in case of emergency discharge, and it should be installed so that there are no obstacles around it.

3D Face Dimensions and New Fit Test Panels for the Labor Population Using Respirators in South Korea (호흡보호구 사용 노동인구의 3차원 얼굴사이즈 특징 및 한국형 밀착도 검사 패널 개발)

  • Jung-Keun Park;Se-Dong Kim;Hyoun-Min Cho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.247-264
    • /
    • 2023
  • Objectives: The study was to examine the features of three-dimensional(3D) face dimensions and to develop fit test panels for the labor population using respirators in South Korea. Methods: This study was part of the first-year work of a two-year-project conducted at Occupational Safety and Health Research Institute in 2021. After 3D head dimensions data were collected from Size Korea Center managing Sixth Size Korea databases, 3D face dimensions DB for the South Korean labor population was established for 21 items of face dimensions in line with the ISO/TS 16976-2 and KS A ISO 15535. With the South Korean labor population 3D face dimensions DB, in accordance with the ISO/TS 16976-2, the descriptive statistics of 3D face dimensions were calculated and two fit test panels were developed. Results: A total of 2,752 subjects were finally determined and they were 52.9% for male, 41.2% for the highest age-group of 15-29, and residents in the capital area. Mean and standard deviation were obtained for each of the 21 3D face dimensions items for the South Korean labor population. Among the items, male and female face widths were 137.6±5.7 mm, 133.2±5.0 mm, respectively. Male and female face lengths were 116.6±7.0 mm, 107.8±6.8 mm, respectively. Two new South Korean fit test panels, a bivariate test panel and a principal component analysis test panel, were developed using the 3D face dimensions DB as well. Conclusions: Using the 3D face dimensions DB, the mean and standard deviation were featured for each of the 21 items and also the two fit test panels were newly developed in the study. It is suggested that the study outputs should be utilized practically and effectively in selection, use, and management of respirators at work, expecting that respiratory protection can be furthermore improved for respirator users including labor population across the country.