• Title/Summary/Keyword: KRS site

Search Result 15, Processing Time 0.016 seconds

Integration, Verification, Qualification Activities for KASS System (KASS 시스템 통합 및 검증 활동)

  • Hwanho Jeong;Minhyuk Son;ByungSeok Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.782-787
    • /
    • 2023
  • Korea augmentation satellite system (KASS) integration, verification, qualification (IVQ) activity is verification of requirements for KASS system and its sub-system that were performed based on the inspection, analysis, review of design, test (IART) method from factory acceptance test (FAT) to test readiness review (TRR) after critical design review (CDR) was closed. In the FAT phase, developed equipment was installed on the test platform and we were verified interfaces between sub-systems and coupling test with the kass control station (KCS). In the site aceeptance test (SAT) phase, on-site verification was conducted by installing equipment verified by FAT such as kass reference station (KRS), kass processing station (KPS), kass uplink station (KUS), KCS. However, considering the developed plan and status, SAT was divided into 3 phases and coupling test was performed. In the TRR phase, the KASS system verification was performed through FAT's test list and additional test list using the satellite based augmentation system (SBAS) broadcast signal from geostationary earth orbit (GEO) 1.

A Numerical Study of the Performance Assessment of Coupled Thermo-Hydro-Mechanical (THM) Processes in Improved Korean Reference Disposal System (KRS+) for High-Level Radioactive Waste (수치해석을 활용한 향상된 한국형 기준 고준위방사성폐기물 처분시스템의 열-수리-역학적 복합거동 성능평가)

  • Kim, Kwang-Il;Lee, Changsoo;Kim, Jin-Seop
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.221-242
    • /
    • 2021
  • A numerical study of the performance assesment of coupled thermo-hydro-mechanical (THM) processes in improved Korean reference disposal system (KRS+) for high-level radioactive waste is conducted using TOUGH2-MP/FLAC3D simulator. Decay heat from high-level radioactive waste increases the temperature of the repository, and it decreases as decay heat is reduced. The maximum temperature of the repository is below a maximum temperature criterion of 100℃. Saturation of bentonite buffer adjacent to the canister is initially reduced due to pore water evaporation induced by temperature increase. Bentonite buffer is saturated 250 years after the disposal of high-level radioactive waste by inflow of groundwater from the surrounding rock mass. Initial saturation of rock mass decreases as groundwater in rock mass is moved to bentnonite buffer by suction, but rock mass is saturated after inflow of groundwater from the far-field area. Stress changes at rock mass are compared to the Mohr-Coulomb failure criterion and the spalling strength in order to investigate the potential rock failure by thermal stress and swelling pressure. Additional simulations are conducted with the reduced spacing of deposition holes. The maximum temperature of bentonite buffer exceeds 100℃ as deposition hole spacing is smaller than 5.5 m. However, temperature of about 56.1% volume of bentonite buffer is below 90℃. The methodology of numerical modeling used in this study can be applied to the performance assessment of coupled THM processes for high-level radioactive waste repositories with various input parameters and geological conditions such as site-specific stress models and geothermal gradients.

Demonstration of Heat Dissipation Performance of Copper Plate in Engineered Barrier System

  • Minsoo Lee;Jin-Seop Kim;Min-Seop Kim;Seok Yoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.22 no.2
    • /
    • pp.105-115
    • /
    • 2024
  • In this study, we employed a small-scale experiment to demonstrate the introduction of a thin copper heat dissipation plate into a bentonite buffer layer of an engineered barrier system. This experiment designed for spent nuclear fuel disposal can effectively reduce the maximum temperature of the bentonite buffer layer, and ultimately, make it possible to reduce the area of the disposal site. For the experiment, a small-scale engineered barrier system with a copper heat dissipation plate was designed and manufactured. the thickness of the cylindrical buffer was about 2 cm, which was about 1/20 of KAERI Repository System (KRS). At a power supply of 250 W, the maximum buffer temperature reduced to a mere 1.8℃ when the thin copper plate was introduced. However, the maximum surface temperature reduced to a remarkable 9.1℃, when a U-collar copper plate was introduced, which had a good contact with the other barrier layers. Consequently, we conclude that the introduction of the thin copper plate into the engineered barrier system for spent nuclear fuel disposal can effectively reduce the maximum buffer temperature in high-level radioactive waste disposal repositories.

A SYSTEMS ASSESSMENT FOR THE KOREAN ADVANCED NUCLEAR FUEL CYCLE CONCEPT FROM THE PERSPECTIVE OF RADIOLOGICAL IMPACT

  • Yoon, Ji-Hae;Ahn, Joon-Hong
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.17-36
    • /
    • 2010
  • In this study, we compare the mass release rates of radionuclides(1) from waste forms arising from the KIEP-21 pyroprocessing system with (2) those from the directly-disposed pressurized-water reactor spent fuel, to investigate the potential radiological and environmental impacts. In both cases, most actinides and their daughters have been observed to remain in the vicinity of waste packages as precipitates because of their low solubility. The effects of the waste-form alteration rate on the release of radionuclides from the engineered-barrier boundary have been found to be significant, especially for congruently released radionuclides. the total mass release rate of radionuclides from direct disposal concept is similar to those from the pyroprocessing disposal concept. While the mass release rates for most radionuclides would decrease to negligible levels due to radioactive decay while in the engineered barriers and the surrounding host rock in both cases even without assuming any dilution or dispersal mechanisms during their transport, significant mass release rates for three fission-product radionuclides, $^{129}I$, $^{79}Se$, and $^{36}Cl$, are observed at the 1,000-m location in the host rock. For these three radionuclides, we need to account for dilution/dispersal in the geosphere and the biosphere to confirm finally that the repository would achieve sufficient level of radiological safety. This can be done only after we have known where the repository site would by sited. the footprint of repository for the KIEP-21 system is about one tenth of those for the direct disposal.

Coupled 3D thermal-hydraulic code development for performance assessment of spent nuclear fuel disposal system

  • Samuel Park;Nakkyu Chae;Pilhyeon Ju;Seungjin Seo;Richard I. Foster;Sungyeol Choi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3950-3960
    • /
    • 2024
  • As a solution to the problem of spent nuclear fuels (SNFs), the disposal of SNF has gained attention from nations using nuclear energy because of hazards posed to the ecosystem. Among many proposed solutions, the most promising method is to dispose of SNF in a deep geological repository (DGR) which utilizes the multi-barrier concept developed by Finland and Sweden. Here, a new fully-coupled Thermal-Hydraulic (TH) code HADES (High-level rAdionuclide Disposal Evaluation Simulator) is developed using the MOOSE framework. This new code suggests basic numerical tools, such as a non-linear solver and finite element discretization, to assess the safety performance of disposal systems. The new TH code considered various TH behavior using Richards' flow approach, assuming gas pressure is constant. The HADES showed promising results when it was compared to various TH codes validated from DECOVAELX-THMC projects. When the single-canister model was utilized to estimate the TH behavior of the Korean Reference disposal System, although it showed significant saturation reduction due to the evaporation of water, the temperature was maintained under the thermal criteria limit, which is 100 ℃. In addition, the new code estimated temperature and degree of saturation of the multi-canisters model, considering two or three canisters, it showed a slightly lower temperature, 5 ℃, than the single-canister model. From these results, the following are concluded: (1) the new TH code contribute to an additional integrity by estimating TH behavior of KRS; (2) however, due to limitations in single-canister simulation, it is recommended to use multi-canisters simulation to estimate TH behavior accurately. Therefore, this model is anticipated not only to help licensing applications and estimation of various multi-physics phenomena and multi-canister at the disposal site.