• Title/Summary/Keyword: KRISS

Search Result 589, Processing Time 0.027 seconds

A study on the development of phthalate plasticizers CRM in ABS resin (ABS 중 phthalates 가소제 CRM 개발에 대한 연구)

  • Jung, Jung-Sul;Park, Jung-Woo;Yoo, Seok;Kweon, Seong-Il;Hong, Sung-Taeg;Sun, Yle-Shik;Park, Cheon-Min;Choi, Chang-Hyoo
    • Analytical Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.273-283
    • /
    • 2012
  • Phthalate plasticizers are regulated by RoHS, REACH and CPSC as hazardous substances. Responding to these international environmental restrictions, we developed ABS certified reference material (CRM) for determination of phthalate plasticizers such as DMP, DEP, DBP, BBP, DEHP and DnOP. The candidate material has been made with ABS resin widely used in electric and electronic products and 6 kinds of phthalate plasticizers. The making of the material involved a series of processes like extruding, cooling, pelletizing, and drying using twin screw extruder. Then it has been certified according to ISO Guide 35. Using isotope dilution-gas chromatography/mass spectrometry (ID-GC/MS), homogeneity, short-term stability, and long-term stability were evaluated. The certified values were determined by using primary reference material (PRM) of KRISS for traceability. From now on, we will provide ABS CRM to national and international companies and research institutes after certification as certified reference material and registering on COMAR (code of reference material).

Proficiency Test of Water Flow Rate for Measurement Equivalence Among KOLAS Accredited Laboratories (KOLAS 교정기관의 측정동등성 확립을 위한 물유량 숙련도 시험)

  • Chun, Sejong;Yoon, Byung-Ro;Kim, Soo-Jin
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.105-113
    • /
    • 2017
  • KOLAS (KOrea Laboratory Accreditation Scheme) belongs to APLAC (Asia Pacific Laboratory Accreditation Cooperation). KOLAS manages the accreditation scheme for measurement traceability to SI units. As per June 2016, there are 22 KOLAS laboratories for liquid flow metering. Among them, 12 laboratories participated in the proficiency test (PM2015-08) for water flow metering, organized by KASTO (Korea Association of Standards and Testing Organizations). This proficiency test was performed with three kinds of flow ranges ($3.6m^3/h{\sim}12m^3/h$, $40m^3/h{\sim}80m^3/h$, $40m^3/h{\sim}200m^3/h$) considering the CMC (calibration and measurement capability) of the participating laboratories. The purpose of the proficiency test was to find out measurement equivalence of the CMC's between each participating laboratory and the reference testing laboratory (KRISS). The measurement equivalence was tested by the number of equivalence ($E_n$). If ${\mid}E_n{\mid}$ < 1, the measurement equivalence was established. All the participating laboratories passed this proficiency test.

Development of Automatic Evaluation Equipment for Burden of Instrument Transformer using Resistor Simulator (저항기를 이용한 계기용 변성기 부담 자동 평가 장치 개발)

  • Lee, Young Seob;Jung, Jae Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.589-595
    • /
    • 2014
  • The error of instrument transformers is measured by connecting the external burden with the secondary terminal of the instrument transformers. Because the error of transformer is affected by the apparent power and power factor of the external burden, an accurate measurement of burden is important for transformer evaluation. We have developed the burden evaluation equipment for both potential transformer and current transformer by employing the series resistor in the range of $20m{\Omega}{\sim}5{\Omega}$ and the parallel resistor in the range of $1M{\Omega}{\sim}500{\Omega}$, respectively, together with visual basic program. We could reduce testing time more than 5 times by employing method developed in this study, compared with that developed in past. This method shows more better reliability by analyzing the evaluation results and fitting graphs of burden measurements. The test results of the developed system is compared with those obtained in the power meter analyzer to verify the validity.

Compliant Ultrasound Proximity Sensor for the Safe Operation of Human Friendly Robots Integrated with Tactile Sensing Capability

  • Cho, Il-Joo;Lee, Hyung-Kew;Chang, Sun-Il;Yoon, Euisik
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.310-316
    • /
    • 2017
  • The robot proximity and tactile sensors can be categorized into two groups: grip sensors and safety sensors. They have different performance requirements. The safety sensor should have long proximity range and fast response in order to secure enough response time before colliding with ambient objects. As for the tactile sensing function, the safety sensor need to be fast and compliant to mitigate the impact from a collision. In order to meet these requirements, we proposed and demonstrated a compliant integrated safety sensor suitable to human-friendly robots. An ultrasonic proximity sensor and a piezoelectric tactile sensor made of PVDF films have been integrated in a compliant PDMS structure. The implemented sensor demonstrated the maximum proximity range of 35 cm. The directional tolerance for 30 cm detection range was about ${\pm}15^{\circ}$ from the normal axis. The integrated PVDF tactile sensor was able to detect various impacts of up to 20 N in a controlled experimental setup.

Solvent Vapor Annealing Effects in Contact Resistances of Zone-cast Benzothienobenzothiophene (C8-BTBT) Transistors

  • Kim, Chaewon;Jo, Anjae;Kim, Heeju;Kim, Miso;Lee, Jaegab;Lee, Mi Jung
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.4
    • /
    • pp.411-416
    • /
    • 2016
  • Benzothienobenzothiophene ($C_8-BTBT$) is a soluble organic small molecule material with high crystallinity resulting from its strong self-organizing properties. In addition, the high mobility and easy fabrication of $C_8-BTBT$ make it very attractive in terms of organic thin-film transistors. In this work, we made $C_8-BTBT$ thin films by using the zone-casting method; we also used an organic solvent to treat the devices with solvent vapor annealing to improve the electrical properties. As a result, we confirmed improved mobility, threshold voltage, and subthreshold swing after solvent vapor annealing. To prove the effect of solvent vapor annealing, we used the simultaneous extraction model to extract the contact resistance from the current-voltage curve. We confirmed that the electrical properties improved with decreasing contact resistance.

Nondestructive Evaluation Technology and Reliability of Products

  • Lee, Joon-Hyun;Lee, Seung-Suck
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.235-238
    • /
    • 2001
  • It is well known that the reliability of materials of mechanical products is becoming more and more important not only for assurance of quality, but for international competition of products. In order to assure the reliability of materials or mechanical products nondestructive evaluation (NDE) techniques are playing more important roles. The existence of Internal defects in materials or mechanical parts is served as crack initiation site during the various loading condition. Historically, nondestructive evaluation (NDE) technique has been used almost exclusively for detecting microscopic discontinuities In materials or mechanical parts after they have been in service to expand the role of the NDE to include all aspects of materials production and application. Research efforts are being directed at developing and perfecting NDE techniques capable of monitoring (1) materials production processes (2) material integrity following transport, storage and fabrication and (3) the amount and rate of degradation during service. In addition, efforts are underway to develop technique capable of quantitative discontinuity sizing, permitting determination of response using fracture mechanics analysis, as well as techniques for quantitative materials characterization to replace the qualitative techniques used in the past. In this paper, the important role of NDE technology for reliability assurance of materials/mechanical parts is introduced.

  • PDF

Estimation of Neutron Energy Spectrum of Cf-252 using Single Bonner Sphere with TLD-600 and TLD-700 (단일 보너구와 TLD-600 및 TLD-700을 이용한 Cf-252의 중성자 에너지 스펙트럼 평가)

  • Kim, Sunghwan;Cheon, Jongkyu;Lee, Jae Jin;Nam, Uk-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.223-226
    • /
    • 2013
  • We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from $10^{-1}$ to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.

Separation Algorithm for 2D Refractive Index Distribution and Thickness Measurement of Transparent Objects using Multi-wavelength Source (다파장 광원을 이용한 위상 물체의 2 차원 굴절률 분포와 두께 측정을 위한 분리 알고리즘)

  • Lee, Kwang-Chun;Ryu, Sung-Yoon;Lee, Yun-Woo;Kwak, Yoon-Keun;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.72-78
    • /
    • 2009
  • We propose the separation algorithm to simultaneously measure two-dimensional refractive index distribution and thickness profile of transparent samples using three wavelengths. The optical system was based on the Mach-zehnder interferometer with LD (Laser Diode)-based multi-wavelength sources. A LCR (Liquid Crystal Retarder) was used to obtain interference images at four phase states and then the optical phase of the object is calculated by four-bucket algorithm. Experimental results with a glass rod are provided at the different wavelengths of 635nm, 660nm and 675nm. The refractive indices of the sample are distributed with accuracy of less than 0.0005 and the thickness profile of sample was cylindrical type. This result demonstrates that it is possible to separate refractive index distribution and thickness profile of samples in two dimensions using the proposed algorithm.

Improvement of Sensitivity to In-plane Strain/Deformation Measurement by Micro-ESPI Technique (마이크로 ESPI 기법에 의한 면내 변형 측정 민감도 향상)

  • Kim D.I.;Huh Y.H.;Kee C.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1442-1445
    • /
    • 2005
  • Several test methods, including micro strain/deformation measurement techniques, have been studied to more reliably measure the micro properties in micro/nano materials. Therefore, in this study, the continuous measurement of in-plane tensile strain in micro-sized specimens of thin film materials was introduced using the micro-ESPI technique. TiN and Au thin films 1 and $0.47\;\mu{m}$ thick, respectively, were deposited on the silicon wafer and fabricated into the micro-sized tensile specimens using the electromachining process. The micro-tensile loading system and micro-ESPI system were developed to measure the tensile strain during micro-tensile test. The micro-tensile stress-strain for these materials was determined using the algorithm for continuous strain measurement. Furthermore, algorithm for enhancing the sensitivity to measurement of in-plane tensile strain was suggested. According to the algorithm for enhancement of sensitivity, micro-tensile strain data between interfringe were calculated. It is shown that the algorithm for enhancement of the sensitivity suggested in this study makes the sensitivity to the in-plane tensile strain increase.

  • PDF

National Vacuum Standards from Low to Ultra-high Vacuum (저진공에서 초고진공까지의 국가 진공표준)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • Vacuum laboratory in Korea Research Institute of Standards and Science (KRISS) was opened in 1983 for establishing and disseminating vacuum standard in Korea. The major three systems such as the ultrasonic interferometer manometer (UIM), the static expansion system (SES) and the dynamic expansion system (DES) with orifice and porous plug conductance are developed. In this study, the standard systems from low to ultra-high vacuum, uncertainty analysis by ISO regulation, and key and bilateral comparison results will be described.