• Title/Summary/Keyword: KEPCO System

Search Result 1,670, Processing Time 0.042 seconds

A study on the Algorithm for the Economic Dispatch of Thermal Units Considering Dynamic Characteristics of Load (부하의 동특성을 고려한 화력발전기의 경제부하배분 앨고리즘에 관한 연구)

  • Song, Kil-Yeong;Park, Kyeng-Soo;Choi, Jae-Suck;Park, Hyun-Sin
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.92-94
    • /
    • 1988
  • One of the recurring problems facing energy control center dispatchers each day is how to operate the system during the periods of high load pick up and fluctuation. This method reduces the problem to a forward - revised by backward - sequence of dispatch problem, with the generator Limits being carefully adjusted between each time interval in the total intervals to be optimized. It is applied to system of 31 units. It is observed that the method presented here achieves that generation fellows the load changes without any mismatch.

  • PDF

Application of Genetic Algorithm for Loss Minimization in Distribution Systems (배전계통에서 손실 최소화를 위한 유전자 알고리즘의 적용)

  • Jeon, Young-Jae;Kim, Hoon;Lee, Seung-Youn;Son, Hag-Sig;Park, Soung-Ok;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.156-158
    • /
    • 2000
  • This paper presents a efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in distribution systems of radial type. To apply genetic algorithm to reconfiguration of distribution system, in this paper we propose the string type and efficient reconfiguration procedure. We also discuss the more elaborate search techniques of solution space as well as the simple genetic algorithm. The experimental results show that the proposed genetic algorithm have the ability to search a good solution.

  • PDF

Scheduling of Combined Cycle Gas Turbine Using Lagrangian Relaxation Method (Lagrangian Relaxation 법을 이용한 복합 화력 발전기의 기동 정지 계획)

  • Nam, Young-Woo;Park, Jong-Keun;Kim, Sung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.334-336
    • /
    • 2000
  • In Korea, the CCGTs have been installed to about 25% of the total generating capacity. Generally CCGTs determine the System Marginal Prices(SMP) in Cost Based Generation Pool. So the scheduling of CCGTs is very important in daily generation scheduling. This paper describes the scheduling of CCGTs which considers the operating characteristics of them. We use lagrangian relaxation method which decomposes the unit committment problem into the subproblems of the individual unit. In the CCGT subproblem, we define the cost function of CCGT in two way. In Case study, the daily generation scheduling is performed using the data of Korean thermal system.

  • PDF

A Study of applying Optimal MLF for Zonal Pricing Electricity market (지역가격체계의 전력시장에 최적 한계손실계수 적용에 관한 연구)

  • Shin, Dong-Joon;Ko, Yong-Joon;Kim, Jin-O;Lee, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.13-15
    • /
    • 2000
  • This paper suggests the optimal dispatch method by MLF, that gives the appropriate price signal considering power flow and system losses under zonal pricing market. This price signal with MLF effects to dispatch merit order and customer price in the short term, and to connection point of new plant in the long term. In the case study, optimal MLF dispatch method applied to simplified Korean power system. The result shows reduction of loss and northward flow.

  • PDF

Load shedding case study of the refinery plant power system considering dynamic characteristic (정유공장 전력계통 동특성을 고려한 부하차단 적용 사례연구)

  • Lee, Kang-Wan;Lim, Joo-Il;Kim, Hyung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.61-65
    • /
    • 2000
  • This paper presents the load shedding case studies and recommendations of load shedding scheme For improving the reliability to suit the requirements of LG-Caltex refinery plant power sγstem. It is recommended for LG-Caltex to decrease the total generation for the economic dispatch. When the LG-Caltex refinery is isolated from KEPCO utility system, the proper load shedding scheme should be implemented since total generation in LG-Caltex refinery plant is less than the load demand. According to the studies carried out the logic-based load shedding is recommended as the main protection scheme, with the combination of the under-frequency relay load shedding.

  • PDF

Development of Contingency Screening Module for Transient Stability Analysis Program (과도 안정도 해석 프로그램을 위한 상정사고 스크리닝 모듈 개발)

  • Hwang, Jung-Hee;Kim, Chon-Hoe;Jang, Gil-Soo;Lee, Byung-Jun;Kwon, Sae-Hyuk;Cho, Yoon-Sung;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.335-337
    • /
    • 2005
  • The purpose of this work is to explain techniques achieved while developing a transient stability program which is suitable to Korean power system, and to add a module for contingency screening. It concentrates on the development of Contingency Screening Module. In this thesis, a fast contingency screening algorithm SIME(Single Machin Equivalent), which is one of the Hybrid methods for the transient stability assessment is used to develop the contingency screening module. The proposed module is applied to a KEPCO system, and simulation results obtained from the program are compared to those of commercial programs.

  • PDF

Factors Influencing Transient Stability in Network Connected to Wind Power Generation System (풍력발전시스템이 연계된 계통의 과도안정성에 영향을 미치는 요소)

  • Kim, Se-Ho;Oh, Sung-Bo;Ko, Seoung-Min;Ahn, Jae-Hyun;Lee, Soo-Mook;Jang, Si-Ho;Lee, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.535-536
    • /
    • 2006
  • This paper reports investigation into the factors that influence the transient behavior of the wind power generation system following network fault conditions. It is shown that the critical clearing time(CCT) can be affected by various factors contributed by the host network. Such factors include capacity of wind power, power factor, the length of the interfacing line, etc. This investigation is conducted en a simulated grid-connected wind farm using Digsilent Power Factory.

  • PDF

A Study on electrical equipment effect of apartment customer elevator by power quality (전력품질로 인한 아파트 수용가 승강기의 전기적 설비 영향에 관한 연구)

  • Lee, Hee-Tae;Kim, Jae-Chul;Kang, Jang-Gyou;Kim, Gi-Hyun;Seoul, Kyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.304-305
    • /
    • 2006
  • Now there is utilization of elevator increasing continuously, it is one of electrical facilities taking a serious view safety. However, elevator comfortable ride is researched generally Recently aging condition, equipment life, malfunction, other applicancies of power electronics and equipment disturbance effect on power quality and prevention measures are much researches in advanced nation. but awareness is lacking real condition up to now in domestic. Voltage sag, swell, harmonics, surge etc of elevator system is important problem about human safety. and there are many quality compensation to solve these problem of elevator. So to evaluate these problem, in this paper, displayed result through computer simulation for converter of problem, and inverter part by power quality problem in power distribution system.

  • PDF

Construction of 154kV Intelligent Substation for Verification Test (154kV급 실증시험용 인텔리전트 변전소 구축)

  • Chung, Y.H.;Kim, M.S.;Kim, J.B.;Lee, H.S.;Choi, I.H.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.456-457
    • /
    • 2006
  • We have carried out the construction of the 154kV intelligent substation with KEPRI. The Intelligent substation is built in Gochang testing facility of KEPCO and consists of electronic instruments for GIS(gas insulated switchgear), digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are introduced compared with the instrument transformer of conventional type. Digital control Panel(DCP) replaces the LCP(local control panel) which is drived for mechanical operation. For the monitoring of the condition of GIS and TR, various sensors are used. In this Paper, we mention the synopsis and report the progress state of project.

  • PDF

Direct Load Control Algorithm Based Locational and Electric Load Characteristics (지역적 특성과 부하특성을 고려한 직접부하제어 알고리즘)

  • Shin, Ho-Sung;Song, Kyung-Bin;Moon, Jong-Fil;Kim, Jae-Chul;Nam, Bong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.264-265
    • /
    • 2006
  • This paper presents direct load control algorithm based locational and electric load characteristics. Direct load control is defined that demand-side management program activities that can interrupt consumer load at the time of annual peak load by direct control of the utility system operator by interruption power supply to individual appliances or equipment on consumer premises. Korean power system is divided into 14-areas considering branches operating in KEPCO, and electric loads are classified into 19 load groups considering interruption costs in this paper. The purpose of proposed method is to decrease social losses by controlling electric loads mainly whose interruption costs are low. It is expected that the proposed algorithm can be used as the countermeasure for the emergency state of the electric power dispatch in a operation point of view.

  • PDF