• Title/Summary/Keyword: KEPCO Power System

Search Result 1,267, Processing Time 0.032 seconds

A Study On the Improvement Of Proset2000 by a Design Method Using the Uinfied Modelling Language (UML을 사용한 디자인 방법에 의한 계통보호 종합전산 프로그램의 개선에 관한 연구)

  • 최면송;현승호;오성민;오태욱
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.7-12
    • /
    • 2004
  • The role of protective relay with correct setting value is very important for the reliable operation of power : system. The setting process of a protective relay is difficult and requires hard work of calculations. Therefore, KEPCO as been using PROSET2000, a computer program system, in order to automate the setting process of protective relays in power transmission network since 2000. This system has a database and relay setting modules for each type of realy with coresponding Human and Computer Interaction(HCI). For the setting of a new type of relay, it require a new module, a HCI and a database table corresponding to the new relay. But it's update is not easy in case of new type of relay. This paper discussed the update method introducing a concept of Open Interface. It addressd a method to make a new HCI for new relay in view of object-oriented method using UML(Unified Modeling Language). Using the UML, we updated the PROSET2000. HCI screens for a new relay is generated automatically using the information of the new relay stored in the database. And, the database management module is upgraded to solve problems in manage and maintain the database in view of Open Interface.

A Method to Accelerate Convergence of Hessenberg process for Small Signal Stability Analysis of Large Scale Power Systems (대규모 전력계통의 미소신호 안정도 해석을 위한 Hessenberg Process의 수렴특성 가속화 방법)

  • Song, Sung-Geun;Nam, Ha-Kon;Shim, Kwan-Shik;Moon, Chae-Ju;Kim, Yong-Gu
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.871-874
    • /
    • 1998
  • It is most important in small signal stability analysis of large scale power systems to compute only the dominant eigenvalues selectively with numerical stability and efficiency. Hessenberg process is numerically very stable and identifies the largest eigenvalues in magnitude. Hence, transformed system matrix must be used with the process. Inverse transformation with complex shift provides high selectivity centered on the shift, but does not possess the desired property of computing the dominant mode first. Thus, advantage of high selectivity of the transformation can be fully utilized only when the complex shift is given close to the dominant eigenvalues. In this paper, complex shift is determined by Fourier transforming the results of dynamic simulation with PTI's PSS/E transient simulation program. The convergence in Hessenberg process is accelerated using the iterative scheme. Overall, a numerically stable and very efficient small signal stability program is obtained. The stability and efficiency of the program has been validated against New England 10-machines 39-bus system and KEPCO system.

  • PDF

Development of Management System for the Distribution Facilities using RFID (RFID를 이용한 공가시설물 관리시스템 구현)

  • Lim, Yong-Hoon;Ju, Seong-Ho;Choi, Moon-Suk;Park, Jae-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.594-595
    • /
    • 2007
  • RFID(Radio Frequency IDentification)는 사물에 ID태그를 부착하여 정보를 제공하는 것을 기능으로 하여 점차적으로 센싱 기능을 추가하여 발전하고 있다. 본 연구에서는 배전 공가설비인 통신케이블을 관리하기 위하여 RFID를 이용하여 감시 및 순시 정보를 기록, 관리하며 봉인을 위한 지그비 센서태그를 이용하여 무단으로 설치되는 통신케이블을 실시간으로 감시할 수 있는 공가관리시스템을 구현하였다. 570만 전주에 달하는 공가설비를 관리하는 것은 안정적인 전력 공급을 위하여서도 필요하며 공가설비 관리의 IT화를 도모하여 RFID 비즈니스 모델로 활용할 수 있을 것으로 기대된다. 본 연구에서는 이를 위해 전주나 통신케이블에 전자태그를 부착하여 RFID 미들웨어를 통해 데이터를 수집하고 정보시스템에 접속하여 실시간으로 공가시설물 정보를 취득할 수 있는 정보시스템을 구축함으로써 무단 공가설비 설치 감시 및 공가설비 순회 점검 결과를 관리할 수 있도록 데이터베이스에 반영하여 현장의 공가설비내역과 정보시스템의 데이터베이스를 동기화시켜 실시간으로 현황을 파악할 수 있도록 개발하였다.

  • PDF

Partial Discharge Simulation and Analysis Based on Experiment in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Kim, Jeong-Tae;Lee, Jong-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.832-839
    • /
    • 2013
  • This paper describes the simulation and experiment for partial discharge (PD) pulse propagation in 22.9kV CNCV power cables. To investigate the propagation characteristics of PD, experiments are carried out by injecting the PD pulse in 100m-long 60 $mm^2$ CNCV cable in the laboratory. The characteristics of PD are also simulated using EMTP to investigate and analyze PD in the same cable. By comparing the simulation and test results, parameter permittivity is recalculated by considering semiconducting screen in the process of simulation and analysis of PD. After it is proved that simulation results and test results are almost similar in the laboratory, extensive simulations are performed to analyse various PD characteristics such as propagation velocity, attenuation, etc. in 60 $mm^2$ and 325 $mm^2$ CNCV cables. Authors are confident that results obtained in this paper will be used as important technical materials to detect and investigate PD generated in transmission and distribution power cables.

A Study on the Reverse-Power-Flow Phenomenon due to Transformer Wiring Types in Distribution System (배전계통에서 변압기 결선에 의한 역 조류현상에 관한 연구)

  • Shin, Dong-Yeol;Ha, Bok-Nam;Jung, Won-Wook;Cha, Han-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.111-119
    • /
    • 2008
  • As the penetration of distributed generation systems is recently high, there have been metering errors, trips of protective devices in KEPCO distribution systems including an occurrence of false fault-indicator in distribution automation system. The cause of malfunctions was the reverse-power-flow phenomenon due to transformer wiring types. By the effect of the reverse-power-flow, each of phase's fundamental currents was added by about 3 times on the neutral line. A new method based on the analysis of the reverse-power-flow is proposed in this paper. Fault currents on each section were analyzed by the proposed method, and the effect of types of transformer wiring was examined experimentally. In order to reduce the malfunctions due to the reverse-power-flow, controlling the zero-sequence impedance of transformer was designed and verified by using PSCAD/EMTDC software.

A Study on the Feasibility of IGCC under the Korean Electricity Market (국내 전력거래제도하에서 IGCC 사업성 확보를 위한 정책 제언)

  • Ko, Kyung-Ho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.1
    • /
    • pp.118-127
    • /
    • 2011
  • An IGCC was evaluated as one of the next generation technologies that would be able to substitute for coal-fired power plants. According to "The 4th Basic Plan of Long-term Electricity Supply & Demand" which is developed by the Electricity Business Acts, the first IGCC will be operated at 2015. Like other new and renewable energy such as solar PV, Fuel cell, The IGCC is considered as non-competitive generation technology because it is not maturity technology. Before the commercial operation of an IGCC in our electricity market, its economic feasibility under the Korean electricity market, which is cost-based trading system, is studied to find out institutional support system. The results of feasibility summarized that under the current electricity trading system, if the IGCC is considered like a conventional plant such as nuclear or coal-fired power plants, it will not be expected that its investment will be recouped within life-time. The reason is that the availability of an IGCC will plummet since 2016 when several nuclear and coal-fired power plants will be constructed additionally. To ensure the reasonable return on investment (NPV>0 IRR>Discount rate), the availability of IGCC should be higher than 77%. To do so, the current electricity trading system is amended that the IGCC generator must be considered as renewable generators to set up Price Setting Schedule and it should be considered as pick load generators, not Genco's coal fired-generators, in the Settlement Payment.

Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests (풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석)

  • Lee, Dooyoung;Goo, Jaeryang;Park, Sooman;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • In this paper, the wind tunnel test for the measurement of aerodynamic characteristics of transmission conductors with asymmetric sections is described. A single conductor model and bundled conductor models with ice accreted shapes are tested both in steady and turbulent flow, and the aerodynamic coefficients are acquired. Transmission conductor galloping is a kind of wind-induced vibration which is characterized by primarily vertical oscillation with a very low frequency and a high amplitude. It is well known that transmission conductor galloping is generally caused by moderately strong, steady winds when a transmission conductor has an asymmetric cross-section shaped by accreted ice. Galloping should be considered from the design stage of overhead lines because it can cause severe wear and fatigue damage to attachments as well as transmission conductors. It is reported that there have been normally 20 events of galloping per year in Korea, which may be followed by serious consequences in the electric power system. Therefore, this research is performed to measure aerodynamic characteristics of ice accreted transmission conductors to understand and control transmission conductor galloping so that it would help to prevent unexpected failures and reduce the maintenance costs caused by galloping.

The Research about Analyzing the Charging Pattern using the Electric Vehicle Running Feature Simulation (전기자동차 운행특성 모의를 통한 충전패턴 분석에 관한 연구)

  • Lim, You Seok;Bang, Chang Hyun;Han, Seung Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.205-214
    • /
    • 2013
  • In this paper, we analyzed the various EV charging-infra information(charging status, charging pattern, charging rate, charging fee, etc.) through the charging infra simulator which would be of help to effectively construct the EV charging infrastructure. The proposed simulator virtually made the EV motoring pattern referred to TMS(Traffic Monitoring System) & Ministry of Land, Transport and Maritime Affairs, and analyzed the charging-infra information(amount of charging, accumulated charging fee, etc.) based on vehicle types, charging type, time and days using EV charging-fee list noticed by KEPCO. Through this simulator, we deducted some considerable contents to build the EV charging infrastructure similarly with real environment.

Synthesis of the Raw Materials of Polycarbonate and Polyurethane by CO2 Chemical Utilization (이산화탄소의 화학적 전환에 의한 폴리카보네이트 및 폴리우레탄의 원료 합성)

  • Baek, Jun-Hyeon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.187-192
    • /
    • 2016
  • Chemical utilization of $CO_2$ is recognized as the technology for the reduction of greenhouse gas as well as the use of carbon to resources. Although various chemicals are commercially produced, the innovative development is still necessary to utilize large quantity of $CO_2$. In this report, the current status of technology to preserve -CO-O- linkage into the molecules was introduced, particularly for the synthesis of dimethyl carbonate (DMC) and polyols, which are raw materials of polycarbonate and polyurethane, respectively. RIST developed the novel process for the DMC production via urea methanolysis and the new catalytic system for polyol synthesis. Because of high contents of $CO_2$ in both chemicals, it is expected that they are able to contribute for the reduction of greenhouse gas.

Hormonic Evaluation of An Imported IAT(Intra Airport Transit) System in Incheon International Airport (인천 국제공항청사 경전철 도입에 따른 고조파 영향 분석)

  • Kim, Jin-O;Song, Hak-Seon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.41-47
    • /
    • 2006
  • This paper presents harmonic evaluation of an IAT(Intra Airport Transit) system in Incheon International Airport. It will be used for electric vehicles with 80[kW] per car produced by Mitsubishi Heavy Industries Ltd, and which is constructed with SIV(Static Inverter), VVVF controller and two induction motor. The vehicles operated in the IAT system can be treated as rapidly changing DC loat and at a feeding substation, 3-phase electric power is transferred to DC 750[V] by rectifier. Since vehicles are changing continuously, the voltages for the load fluctuate in the IAT system, and moreover, the voltage fluctuation generates high-order harmonics. It results the difficulty in maintaining power quality in KEPCO systems' side. The power quality of the IAT system in Incheon International Airport is evaluated using PSCAD/EMTDC simulator in the paper. The THD(Total Harmonic Distortion) of voltages and TDD(Total Demand Distortion) of currents, indices are calculated for the IAT system using the results of PSCAD/EMTDC dynamic simulation.