• 제목/요약/키워드: KDS41

검색결과 19건 처리시간 0.018초

코어 외 추가 벽체와 기둥 띠철근 간격이 필로티 건물의 내진성능에 미치는 영향 (Effect of Stirrup Spacing of Columns and an Additional Wall other than Core Walls on the Seismic Performance of Piloti-type Buildings)

  • 이수정;김태완
    • 한국지진공학회논문집
    • /
    • 제28권4호
    • /
    • pp.171-181
    • /
    • 2024
  • For low-rise piloti-type buildings that suffered significant damage in the Pohang earthquake, the seismic performance of those designed by codes issued before and after the earthquake has been recently revised. This study started with the expectation that many of the requirements presented in the current codes may be excessive, and among them, the spacing of column stirrup could be relaxed. In particular, the recently revised design code of concrete structures for buildings, KDS 41 20 00, suggests that the column stirrup spacing is 1/2 of the minimum cross-sectional size or 200 mm, which is strengthened compared to KBC 2016, but relaxed than the current KDS, 41 17 00, which is 1/4 of the minimum size or 150 mm. As a result of the study, it was found that the target performance level was sufficiently satisfied by following the current standards and that it could be satisfied even if the relaxed spacing was followed. Therefore, the strict column stirrup spacing of KDS 41 17 00 could be relaxed if a wall other than core walls is recommended in the current guideline for the structural design of piloti-type buildings.

KDS 41 17 00에 따라 설계된 저층 필로티 건물의 지진 취약도 (Seismic Fragility of Low-rise Piloti Buildings Designed According to KDS 41 17 00)

  • 주창혁;김태완
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.49-58
    • /
    • 2022
  • The 2017 Pohang earthquake caused severe damage to low-rise piloti buildings. The damage was caused mainly by column shear failure, and some core walls were as well. The damaged piloti buildings in Pohang City could be relieved if they were designed correctly according to the standards at that time. However, the post-earthquake investigation revealed design, construction, and permission problems. To solve the problems, the Piloti Building Structure Design Guidelines that include strict specifications were published in 2018. Separately, KDS 41 17 00, the seismic design standard for buildings, was enacted in 2019 and it included the guideline contents. Therefore, at least after the publication of the guidelines, piloti buildings, designed by the standard and guidelines, can be expected to possess better seismic performance than existing piloti buildings. To confirm this, the probability of exceedance for several damage state thresholds was estimated for existing and designed piloti buildings. As a result, the probability of damage of designed piloti buildings was very low compared to existing ones. Consequently, it was confirmed that the guideline and standard adequately supplement the structural fragility of existing piloti buildings.

일축 압축력을 받는 콘크리트충전 각형강관 단주의 구조적 거동 (Axial Compression of Stub Columns for Concrete-filled Square Steel Tubes)

  • 유영찬
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.617-624
    • /
    • 2021
  • 각형강관 기둥에 콘크리트를 충전하여 사용하는 콘크리트충전 강관구조가 구조부재로 사용되면 기둥 부재의 내력과 변형 능력이 증가되어 높은 효율성을 가진 구조물 구현이 가능해 진다. 콘크리트충전 강관구조에 대한 국내의 설계 기준은 대한건축학회에서 2005년에 제정한 후, 2009년과 2016년에 각각 개정되었다. 연구 목적은 콘크리트충전 각형강관 단주를 대상으로 일축 압축실험을 실시하여 압축내력 및 변형능력에 주는 영향을 파악하고, 국내의 건축구조기준의 기준식을 검증하여 차후 수정 및 보완에 필요한 자료를 제공하는데 있다. 실험에서 강관은 냉간가공으로 제작된 각형강관을 사용하였고, 시험체는 강관의 폭두께비를 변수로 총 26개를 제작하여 중심 압축실험을 실시하였다. 실험결과 콘크리트충전 각형강관 단주의 압축내력과 변위관계 및 파괴모드를 얻었고, 실험결과를 분석하여 콘크리트의 충전효과와 폭두께비의 영향을 파악하였다. 충전된 콘크리트의 압축내력은 일축응력 상태보다 9%정도 증가하였는데, 이것은 차후 건축구조기준에 반영할 필요가 있다. 실험결과를 건축구조기준과 비교한 결과, 냉간가공된 각형강관의 경우 건축구조기준의 콤팩트단면 한계폭두께비 2.26은 다소 과대 평가하고 있기 때문에 수정이 필요하며, 보수적으로 보완한 계수 1.35로 제한하여 보다 더 안정적인 설계식을 제안하였다.

중심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of Low-rise Piloti RC Buildings with Concentric Core)

  • 윤태호
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.611-619
    • /
    • 2022
  • In this study, the seismic performance of low - rise piloti buildings with concentric core (shear wall) position is analysed and reviewed based on KDS 41. The prototype is selected among the constructed low - rise piloti buildings with concentric core designed based on KBC 2005 which was used for many low - rise piloti buildings construction. The seismic performance of the building shows plastic behavior in X-direction and elastic behavior in Y-direction. The inter-story drift is lager than that of concentric core case and is under the maximum allowed drift ratio. The displacement ratio of first story is much lager the that of upper stories, and the frame structure in the first story is evaluated as vulnerable to lateral force. Therefore, low - rise piloti buildings with concentric core need the diminishment of lateral displacement and reinforcement of lateral resistance capacity in seismic design and seismic retrofit.

Through Knee Amputation: Technique Modifications and Surgical Outcomes

  • Albino, Frank P.;Seidel, Rachel;Brown, Benjamin J.;Crone, Charles G.;Attinger, Christopher E.
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.562-570
    • /
    • 2014
  • Background Knee disarticulations (KD) are most commonly employed following trauma or tumor resection but represent less than 2% of all lower extremity amputations performed in the United States annually. KDs provide enhanced proprioception, a long lever arm, preservation of adductor muscle insertion, decreased metabolic cost of ambulation, and an end weight-bearing stump. The role for KDs in the setting of arterial insufficiency or overwhelming infection is less clear. The purpose of this study is to describe technique modifications and report surgical outcomes following KDs at a high-volume Limb Salvage Center. Methods A retrospective study of medical records for all patients who underwent a through-knee amputation performed by the senior author (C.E.A.) between 2004 and 2012 was completed. Medical records were reviewed to collect demographic, operative, and postoperative information for each of the patients identified. Results Between 2004 and 2012, 46 through-knee amputations for 41 patients were performed. The mean patient age was 68 and indications for surgery included infection (56%), arterial thrombosis (35%), and trauma (9%). Postoperative complications included superficial cellulitis (13%), soft tissue infection (4%), and flap ischemia (4%) necessitating one case of surgical debridement (4%) and four transfemoral amputations (9%). 9 (22%) patients went on to ambulate. Postoperative ambulation was greatest in the traumatic cohort and for patients less than 50 years of age, P<0.05. Alternatively, diabetes mellitus and infection reduced the likelihood of postoperative ambulation, P<0.01. Conclusions Knee disarticulations are a safe and effective alternative to other lower extremity amputations when clinically feasible. For patient unlikely to ambulate, a through-knee amputation maximizes ease of transfers, promotes mobility by providing a counterbalance, and eliminates the potential for knee flexion contracture with subsequent skin breakdown.

2400MPa 단일 강연선이 적용된 포스트텐션 정착 구역 설계에 대한 실험적 연구 (Experimental Analysis of Anchorage Zone Design for Unbonded Post-Tensioned Concrete Beam With 2400MPa Single Tendons)

  • 문상필;노경민;김민숙;이영학
    • 한국공간구조학회논문집
    • /
    • 제20권1호
    • /
    • pp.41-48
    • /
    • 2020
  • In this study, the design of anchorage zone for unbonded post-tensioned concrete beam with single tendons of ultimate strength 2400MPa was evaluated to verify that the KDS 14 20 60(2016) and KHBDC 2010 codes are applicable. The experimental results showed that the bursting force equation of current design codes underestimated bursting stress measured by test, because the KDS 14 20 60(2016) and KHBDC 2010 propose the location of the maximum bursting force 0.5h which is the half of the height of member regardless of stress contribution. Although the allowable bearing force calculated by current design codes was not satisfied the prestressing force, the cracks and failure in anchorage zone was not observed due to the strengthening effect of anchorage zone reinforcement.

철근 콘크리트 보의 보강을 위한 하이브리드 조립형 보강기법에 관한 해석적 연구 (Analytical Study on Hybrid Prefabricated Retrofit Method for Reinforced Concrete Beams)

  • 문상필;이성호;이영학;김민숙
    • 한국공간구조학회논문집
    • /
    • 제20권3호
    • /
    • pp.71-79
    • /
    • 2020
  • In this paper, the hybrid prefabricated retrofit method that improve structural performance and reduce construction period was developed by using a finite element analysis. The hybrid prefabricated retrofit method consist of a Z-shaped side plate, a L-shaped lower plate, and a bottom plate containing an steel plate with openings. This shape has advantage that a retrofit method is possible regardless of the size of the beams and a follow-up process such as reinforcement bars placing are not required. The finite element analysis of hybrid Prefabricated retrofit method showed the most ideal stress distribution when the thickness of bottom plate was 10mm, the thickness of the L-shaped lower plate was 5mm, the thickness of the Z-shaped side plate was 2.5mm, and the bolt spacing was 200mm. The bending strength equation of Hybrid prefabricated retrofit method was proposed through the plastic stress distribution method in KDS 41 31 00. The result of Comparison the proposed equation with the finite element analysis, it is determined that the design of hybrid prefabricated retrofit method is possible through the KDS 41 31 00.

고감쇠고무와 강재슬릿이 결합된 하이브리드 댐퍼의 실험적 구조성능평가 (Experimental Structural Performance Evaluation of Hybrid Damper Combining with High Damping Rubber and Steel Slit)

  • 이준호;박병태;김유성
    • 한국공간구조학회논문집
    • /
    • 제22권4호
    • /
    • pp.23-30
    • /
    • 2022
  • It is effective to apply hybrid damping device that combine separate damping device to cope with various seismic load. In this study, HRS hybrid damper(hybrid rubber slit damper) in which high damping rubber and steel slit plate are combined in parallel was proposed and structural performance tests were performed to review the suitability for seismic performance. Cyclic Loading tests were performed in accordance with criteria presented in KDS 41 17 00 and MOE 2019. As a result of the test, the criteria of KDS 41 17 00 and MOE2019 was satisfied, and the amount of energy dissipation increased due to the shear deformation of the high-damping rubber at low displacement. Result of performing the RC frame test, the allowable story drift ratio was satisfied, and the amount of energy dissipation increased in the reinforced specimen compared to the non-reinforced specimen.

NRC 보-기둥 접합부의 구조적 거동 평가 (Structural Behavior Evaluation of NRC Beam-Column Connections)

  • 전지환;이상윤;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권1호
    • /
    • pp.73-80
    • /
    • 2022
  • 본 연구에서는 공장에서 L형강을 이용하여 선조립한 NRC 보와 NRC 기둥을 현장에서 볼트 조립하는 NRC 보-기둥접합부 상세를 개발하였다. 개발된 접합부 상세는 NRC-J형과 NRC-JD형이다. NRC-J형은 NRC 기둥 측면의 강재 플레이트와 NRC 보의 엔드플레이트의 측면과 하부면에 TS볼트로 인장접합하는 방식이다. NRC-JD형은 전단에 대해서 NRC 보와 NRC 기둥의 측면을 고력볼트접합하고, 휨에 대해서 접합부를 관통하는 철근연결재와 보의 보강재를 겹침이음하도록하는 강접합 방식이다. 접합부 내진성능평가를 위하여, 두 가지 NRC 보-기둥 접합부 상세를 가지는 NRC-J 실험체, NRC-JD 실험체와 RC 보-기둥 접합부 상세를 가지는 RC-J 실험체 등 3개의 실험체를 제작하였다. 반복횡하중가력 실험결과, 모든 실험체의 최종 파괴형상은 보-기둥 접합면에서 보의 휨파괴로 나타났다. 정가력에 의한 실험체 최대내력은 RC-J 실험체에 비하여 NRC-J 실험체와 NRC-JD 실험체가 각각 10.1%, 29.6% 크게 나타났다. 두가지 NRC 접합부 상세 모두 KDS 기준(KDS 41 3100)의 합성중간모멘트골조 모멘트접합부에서 요구되는 최소 총층간변위각 0.03 rad 이상의 연성능력을 확보는 것으로 평가되었다. 부재각 5.7%에서 NRC-J실험체, NRC-JD 실험체가 RC실험체에 비해 약 34.8%, 61.1% 큰 누적 에너지 소산능력을 보유하고 있었다. NRC 보-기둥 접합부의 실험내력이 KDS 기준식에 의한 이론내력에 비하여 30%~53% 큰 것으로 평가되어, 기준식이 보유성능을 안전측으로 평가하였다.

국방품질경영시스템 성공요인의 탐색 (An Exploratory Study on the Success Factors of Defence Quality Management System)

  • 박종훈;이상천
    • 산업경영시스템학회지
    • /
    • 제41권4호
    • /
    • pp.160-170
    • /
    • 2018
  • This paper is an exploratory study on the success factors of Defence Quality Management System (DQMS) which is the certification system granted by the military for improving the quality of munitions. DQMS is established by adding military requirements to the ISO standard, thus, we especially focus on the additional requirements to figure out success key factors of DQMS certification. The 51 additional requirements of Korean Defense Specification (KDS) are empirically investigated from 67 companies that acquired DQMS certification. Firstly, we conduct an independent t-tests on 51 additional requirements of KDS 0050-900-3 to determine if there is a difference between an easily certified company and a hard-to-certify company, and obtain 8 requirements such as 'Internal propagation of performance', 'Preparation of documented work instructions', 'Work instructions in the workplace', 'Documentation of equipment management', 'Inventory management', 'Packaging and identification', 'Guarantee of access to internal audit result for customers', 'Notification to the customer for improper product.' Secondly, we carry out an factor analysis to the 51 additional requirements for classification, and figure out that 4 requirements among the 8 requirements above mentioned are grouped together in the same factor. The 4 requirements are 'Preparation of documented work instructions', 'Work instructions in the workplace', 'Packaging and identification', and 'Guarantee of access to internal audit result for customers.' The result of this paper will provide useful information to the company preparing for DQMS.