• 제목/요약/키워드: KDP

검색결과 34건 처리시간 0.027초

수용액중에서 KDP단결정의 육성 (Growth of KDP Single Crystals in Aqueous Solution)

  • 김판채;최경란
    • 한국결정성장학회지
    • /
    • 제2권1호
    • /
    • pp.37-42
    • /
    • 1992
  • KDP단결정의 육성을 서냉법 및 정온법에 의해 행하였다. KDP용해도의 온도계수는 20-80℃의 측정온도 범위에서 positive였다. KDP종자결정은 수용액중의 육성온도가 30℃일 때 큰 결정으로 성장하였다. KDP단결정의 tapering효과는 산도, 과포화 및 육성온도에 의존하였다. KDP-ADP결정은 수용액중 33℃의 육성온도에서 얻을 수 있었다.

  • PDF

KDP결정을 이용한 고강도 Nd 레이저광의 제4 고조파변환 해석 (Analysis of Fourth Harmonic Conversion of High Intensity Nd Laser Beam in KDP Crystal)

  • 장용무;김병태;강형부
    • 대한전기학회논문지
    • /
    • 제41권5호
    • /
    • pp.541-550
    • /
    • 1992
  • The fourth harmonic conversion(FHC) efficiency of high-power Nd laser pulse with wavelength of 1.054x10S0-6Tm using two KDP crystals(doubler adn quadrupler) was simulated numerically. Simulation results show that for the perfect phase-matching condition the FHC efficiency were 60-70% for several hundreds MW/cmS02T class and over 70% for GW/cmS02T class laser pulses. And the overall characteristics of FHC were discussed in terms of effects of input intensity, crystal length, and mismatch angle Δ$\theta$. Optimum method to FHC was type-II doubler & type-I quadrupler KDP crystal because type-II KDP doubler crystal has wide tolerance of acceptance matching-angle.

전기광학적 레이저 변조기 (Electrooptic Laser Modulator)

  • 이문기
    • 대한전자공학회논문지
    • /
    • 제12권3호
    • /
    • pp.13-19
    • /
    • 1975
  • CuCl, KDP 결정체를 이용한 지그재그형 진헹파 전기광학적 레이저 변조기에 대해 자세히 해석했다. 변조기와 크기와 대역폭은 변조용 결정체의 광학적 특성및 M/W유전특성에 의해 결정됨을 알수 있다. 더욱 광손실과 M/W손실의 영향, 입사각, 회절등의 영향을 규명했고 최적 설계법을 제시했다. 중요한 결과를 요약하면 다음과 같다. (1) CuCl, KDP로 10(GHz)이상의 대역폭에서 3(watt)이하의 변조전력으로 50%변조를 얻었다. (2) 변조주파수 한계의 상한은 레이저 빔폭에 의한 차단주파수로 인해 제한된다. A detailed analysis has been carried out of a zigzag traveling wave electro-optic laser modulator usin3 CuCl, KDP Crystal. The inclusion of such practical factors as M/W and optical loss results in an optimum design in which modulator dimensions and bandwidth limitation are uniquely determined by optical and M/W dielectic properties of modulating crystal. The main conclusion of the analysis are: (1) CuCl, KDP may be used to produce 50% modulation over bandwidth of 10(GHz) with less than (watt) of modulating power. (2) The upper modulation frequency limit is set by a cutoff frequency which arises from finite width of optical beam.

  • PDF

Promoter Activity of the Long Terminal Repeats of Porcine Endogenous Retroviruses of the Korean Domestic Pig

  • Ha, Hong-Seok;Huh, Jae-Won;Kim, Dae-Soo;Kang, Dong-Woo;Cho, Byung-Wook;Kim, Heui-Soo
    • Molecules and Cells
    • /
    • 제24권1호
    • /
    • pp.148-151
    • /
    • 2007
  • Porcine endogenous retroviruses (PERVs) in the pig genome represent a potential risk of infection in pig-to-human transplantation and are transmitted vertically. The solitary long terminal repeat (LTR) elements of the PERVs affect the replication properties of the individual viruses via their repeat sequences and by encoding a set of specific transcription factors. We examined the promoter activities of solitary LTR elements belonging to the PERV-A and -B families of the Korean domestic pig (KDP) using luciferase reporters. Three of the LTR structures (of PERV-A5-KDP, PERV-A7-KDP, PERV-A8-KDP) had different promoter activities in human HCT116 cells and monkey Cos7 cells, and potential negatively and positively acting regions affecting transcription were identified by deletion analysis. These data suggest that specific sequences in the U3 region of a given LTR element can affect the activities of promoter or enhancer elements in the PERV.

전기광학변환소자로서의 결정과 그 응용 - 학술강연회초록

  • Naomi Furuya
    • 전기의세계
    • /
    • 제22권3호
    • /
    • pp.79-80
    • /
    • 1973
  • This is the abstract of lecture on Electro-optic characteristics of D-KDP crystal and its application for high speed shutter made by Dr. Naomi Furuya; The professor of Yamanashi University in Kofu Japan on March 31, 1973 for KEEI in the auditorium of Korea Electric Company. His lecture is listened by KEEI members that KDP Z-cut crystal can be utilized as a high speed shutter of 10$^{-6}$ second, combining special camera and 2-3KV electrical impulse generator and also recording slide photographs on tungoten lamp crystal voltage and melting fuse phenomena due to over-current taken by this special equipment had been demonstrated.

  • PDF

강우레이더 관측의 수문학적 불확실도 산정 기법 (Estimation Techniques of Hydrological Uncertainties on Rainfall Radar Measurement)

  • 황석환;조효섭;이건행;현명숙
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.78-78
    • /
    • 2017
  • 강우레이더 관측의 정확도는, 호우의 강도나 형태와 같은 기상학적 조건(변동 오차 요소) 외에도, 관측 지점의 레이더로부터의 거리, 고도, 관측유역의 형태나 크기 등 다양한 관측환경 조건(고정 오차 요소)에 의해서도 달라질 수 있기 때문에, 강우레이더 관측의 오차 성분을 정량화할 필요가 있다. 본 연구에서는 거리와 고도에 의한 오차 특성을 이중편파 변수의 특성을 이용하여 실증적으로 분석하였고, 이를 통해 감쇠의 영향과 산지효과(또는 지형효과)로 인한 오차 규모를 정량적으로 산정 비교하였다. 거리가 멀어짐에 따라 고도도 높아지기 때문에 QPE 불확실도의 거리와 고도에 따른 성분을 구분하는 것은 매우 어려운데, 거리에 대한 불확실도 성분이 매우 작은 R(KDP)를 이용한다면 효과적으로 분리가 가능하다. 이러한 원리를 이용하여, 관측 거리에 따른 오차가 매우 작은 R(KDP)를 기준으로 관측 거리에 따른 오차와 고도에 따른 오차를 분리하여 표준화[Z-score] 하였다. R(Z)의 경우는 관측 고도와 거리에 따른 오차가 중첩되어 나타나나, R(KDP)는 거리에 따른 오차는 거의 나타나지 않으므로 이를 기본 가정으로 하여 R(Z)와 R(KDP) 관계로부터 관측 고도에 따른 오차 성분만 분리하였다. 분리 결과, 관측 거리에 따른 표준 오차의 경우 100km 까지는 대략 10%(0.1) 이하로 나타났으나, 150km 이상에서는 30%(0.3)를 초과하는 것으로 나타났다. 관측 고도에 따른 표준 오차의 경우 2~3번째 고도각 까지는 대략10%(0.1) 이하로 나타났으나, 3번째 고도각 이상에서는 20%(0.2), 4번째 고도각 이상에서는 50%(0.5)를 초과하는 것으로 나타나, 고도에 의한 영향이 거리에 의한 영향보다 민감하게 나타났다. 1번째 고도각에서는, 100km 이내 근거리에서 관측 거리가 가까워질수록 오차가 증가하는 경향을 보이는데, 이는 저고도 빔 간섭(빔 차폐) 등의 영향으로 추정되었다.

  • PDF

Charge Flow in KH2PO4 Lattice Structure by Using the Proton-Beam Irradiation

  • Han, Doug-Young;Han, Jun-Hee;Lee, Cheal-Eui;Kim, Se-Hun
    • 한국자기공명학회논문지
    • /
    • 제12권2호
    • /
    • pp.111-118
    • /
    • 2008
  • The mechanism of charge flow has been probed by measuring the $^{1}H$ chemical shift on a proton-irradiated ${KH_2}{PO_4}$ (KDP) single crystal. The proton irradiation caused the increase in $^{1}H$ chemical shift. It can be interpreted as the electronic charge transfer from the proton to oxygen atom, accompanied with the proton displacement along the hydrogen bond. For the high resolution $^{1}H$ chemical shift measurement, CRAMPS (Combined Rotation And Multiple Pulses) technique is utilized.