Evaluation of Bearing Strength of Self-Tapping Screws according to the Grain Direction of Domestic Pinus densiflora

  • LEE, In-Hwan;KIM, Keonho;SHIM, Kug-bo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권1호
    • /
    • pp.1-11
    • /
    • 2022
  • To evaluate the bearing strength of red pine cross-laminated timber (CLT) with self-tapping screw (STS), which is widely used as a fastener for connection in CLT building, the bearing test was conducted. Accoring to the STS's diameters (8, 10, 12 mm), the bearing test specimens with half hole were manufactured. Bearing strength was compared and reviewed in consideration of the configuration in STS and the loading direction to the grain of red pine. As a result of the bearing test on the STS's diameter, the yield bearing load increases as the larger diameter of the STS in all directions of the red pine. The bearing strength of the thread part (thread + tip) was higher than the shank part (shank + shank cutter). In compared with the directions to the grain of red pine, the bearing strength of the cross section parallel to the loading direction was the highest, and the tangent section was the lowest bearing strength. The average bearing strength of the loading direction in parallel to the grain was 23.43 MPa, which was about 45% higher than the average 16.16 MPa in perpendicular to the grain. The predicted bearing strength calculated by Eurocode (EN) and Korean Building Code (KBC)'s equation was lower than the experimental value. It is nessesary to propose the new equations of bearing strength reflected the configuration information of STS.

고강도 원형강관의 직각방향 거셋플레이트 접합부 실험 및 해석 (Test and Analysis on the Transverse Gusset Plate Connection to Circular Hollow Section(CHS) of High Strength)

  • 이수헌;신경재;이희두;김우범
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.163-173
    • /
    • 2012
  • 원형강관의 접합부는 다양한 상세를 가지고 있으며 접합부가 항복에 이를 경우 복잡한 국부변형을 유발한다. 이러한 접합부의 국부변형을 고려한 단순화된 설계식의 제안은 매우 어려운 문제이다. 원형강관접합부 설계를 위한 현행 한국구조기준(KBC 2009)에서는 AISC의 설계식과 매우 유사한 단순화된 설계식을 제시하고 있다. 현행 설계식은 원형강관 부재의 재질에 대하여 항복강도는 최대 360MPa 항복비는 0.8로 각각 제한하고 있어서 구조기준에서 제한하는 최대항복강도 이상의 강재를 사용할 경우에는 유사 상세접합부를 대상으로 구조실험이나 합리적인 해석 등을 통하여 안전성을 검증한 후 사용하도록 하고 있다. 본 논문에서는 고강도강재(HSB600)와 일반구조용강재 (SS400)를 이용한 원형강관-직각방향 거셋플레이트 접합부에 횡력(수평력)이 작용하는 실험과 정밀모델 유한요소해석을 실시하였다. 유한요소해석 및 실험결과를 현행 설계식과 비교분석하여 향후 접합부 설계식의 개정에 기초적 자료로 사용될 수 있을 것이다.

2행 1열 듀플렉스계 스테인리스강(STS329FLD) 볼트접합부의 최대내력 조사 (An Investigation on the Ultimate Strength of Duplex Stainless Steel (STS329FLD) Bolted Connections with Two Bolts)

  • 안성호;김근영;황보경;김태수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권5호
    • /
    • pp.55-63
    • /
    • 2018
  • 최근에 오스테나이트와 페라이트의 조직을 갖는 듀플렉스계 스테인리스강이 개발되었고 오스테나이트계 스테인리스강에 비해 고강도, 응력부식균열에 대한 고내식성과 재료비절감으로 다양한 산업분야에서 사용량이 증가되고 있다. 그러나, 현재 스테인리스강은 한국 건축구조기준에 구조용재료로 지정되어 있지 않고 구조설계기준도 마련되어 있지 않는 실정이다. 이 연구에서는 2행 1열 듀플렉스계 스테인리스강(STS329FLD) 볼트접합부에 대한 구조적 성능을 조사하기 위한 실험적 연구를 수행하였다. 주요변수는 전단접합형태(일면전단과 이면전단)과 하중방향 연단거리이다. 종국파단형태는 전형적인 블록전단파단, 인장파단과 면외변형이 관찰되었다. 일면전단 접합부에서 면외변형발생으로 최대 20%까지 내력저하가 발생되었다. 실험최대내력은 현행설계기준 AISC/AISI/KBC, EC3와 AIJ 및 기존연구자에 의한 제안된 식에 의한 예측내력과 비교하였다. 면외변형이 발생하지 않은 접합부에 대해서 실제 전단파단단면을 고려한 Clement & The의 식에 의한 예측내력이 실험내력에 가장 근접했고 면외변형을 동반한 접합부에 대해서는 면외변형을 고려해 제안한 Kim & Lim식에 의해서 과대평가하는 것으로 나타났다.

원추형 마찰진자베어링의 내진성능평가 (Seismic Performance Evaluation of a Cone-type Friction Pendulum Bearing System)

  • 전법규;장성진;박경록;김남식;정득영
    • 한국지진공학회논문집
    • /
    • 제15권2호
    • /
    • pp.23-33
    • /
    • 2011
  • 본 연구에서는 중요 통신장비의 지진발생시 파손 및 성능저하를 방지하기 위하여 구조물로 전달되는 가속도를 조절할 수 있는 CFPBS(Cone-type Friction Pendulum Bearing System:원추형 마찰진자베어링)를 개발하고 내진성능을 검증하였다. CFPBS는 기존의 FPS(Friction Pendulum System)와 다르게 원추형으로 제작되었으며 보다 큰 마찰력을 얻기 위하여 마찰면에 패턴을 음각하였다. CFPBS의 고유성능을 파악하기 위하여 4개의 CFPBS가 하나의 개체를 이루도록 제작된 지진격리장치를 이용하여 자유진동시험을 수행하였다. 운동방정식으로부터 유도된 CFPBS의 이론식과 Newmark-${\beta}$ Method를 이용하여 내진성능을 검증하기위한 MATLAB7.0 기반의 동적 수치해석프로그램을 제작하였으며 CFPBS의 제작 시 원하는 성능을 발휘할 수 있도록 간략화된 CFPBS의 설계식을 제안하였다. 수치해석을 통한 CFPBS의 내진성능평가를 위하여 건축구조설계기준(KBC-2005)의 최대지진규모에 해당하는 인공지진파를 생성하고 검증하였다. El Centro NS(1940)와 Kobe NS(1995), 인공지진파 등을 사용하여 CFPBS의 상부질량과 경사각을 매개변수로 하는 수치해석을 수행하였다. 수치해석의 결과를 토대로 CFPBS의 내진성능을 평가하였으며 수치해석의 결과와 설계식을 이용하여 동일한 조건에서 얻어진 결과를 비교분석하였다.

편심하중을 받는 건축구조용 고강도 강재(HSA800) 단주의 거동에 관한 실험적 연구 (An Experimental Study on the Structural Behavior of Stub Columns with HSA800 High-strength Steels under Eccentric Loads)

  • 이강민;이명재;오영석;오근영;홍성빈
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.289-297
    • /
    • 2014
  • 본 연구에서는 고강도강재(HSA800)의 단주 편심압축실험을 통해 휨-압축 부재의 강도를 평가하였다. 편심압축실험은 축력비에 따라 휨-압축의 조합력을 받는 부재의 P-M 상관관계를 알아보기 위해 HSA800강재의 각형강관과 H형강을 대상으로 실험을 수행하였으며, 가력 편심거리를 조정하여 다양한 P-M 조합에 대해 강도평가 실험을 수행하였다. 실험결과 실험최대 평균응력은 국부좌굴에 의한 최대내력이 결정된 실험체에 대해서는 판폭두께비가 증가함에 따라 감소하는 경향을 보였다. 발현강도의 여유는 축력이 낮을수록 상대적으로 휨강도에 대해 큰 마진을 보이고 있었고, 실험체 모두 현행 설계기준의 P-M 상관관계를 안전측으로 충족하였다.

Base isolation performance of a cone-type friction pendulum bearing system

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Kim, Sung-Wan;Kim, Nam-Sik
    • Structural Engineering and Mechanics
    • /
    • 제53권2호
    • /
    • pp.227-248
    • /
    • 2015
  • A CFPBS (Cone-type Friction Pendulum Bearing System) was developed to control the acceleration delivered to a structure to prevent the damage and degradation of critical communication equipment during earthquakes. This study evaluated the isolation performance of the CFPBS by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced with the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with a seismic isolator system consisting of 4 CFPBS. To confirm the earthquake-resistant performance, a numerical analysis program was prepared using the equation of the CFPBS induced from the equations of motion. The equation reported by Tsai for the rolling-type seismic isolation bearings was proposed to design the equation of the CFPBS. Artificial seismic waves that satisfy the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and the skew angle of friction surface were considered for numerical analysis with El Centro NS, Kobe NS and artificial seismic waves. The CFPBS isolation performance evaluation was based on the numerical analysis results, and comparative analysis was performed between the results from numerical analysis and simplified theoretical equation under the same conditions. The validity of numerical analysis was verified from the shaking table test.

T형 벽체의 유효 폭 및 휨강도 평가 (Evaluation of the Effective Width and Flexural Strength of the T-Stalled Walls)

  • 양지수;이리형
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.796-803
    • /
    • 2002
  • T형 벽체는 웨브 벽체와 평행한 방향으로 횡력이 작용할 때 그 작용 방향에 따라 다른 강성과 강도를 갖는다. 특히, 플랜지벽체에 인장력이 작용할 때 플랜지 벽체내 철근의 기여로 인하여 벽체의 휨강도가 상승하게 되는데 이것은 전단지체 현상에 기인한 것이다. 이러한 전단지체 현상에 따라 플랜지 벽체는 전체 폭이 웨브 벽체와 일체로 거동하지 못하고, 일정한 부분만이 웨브 벽체와 함께 거동하게 되는데, 이러한 범위를 유효 폭이라 하며, 이러한 유효 폭은 구조물의 실제적인 강도와 강성을 예측하는데 중요한 역할을 하게되므로 반드시 구명되어야 할 요소라 할 수 있다. 이에 본 연구에서는 실험을 통하여 웨브 벽체 단부에 기존의 양단부 보강상세를 갖는 T형 벽체의 실제적인 강도와 유효 폭을 평가하고자 한다. 연구목적을 달성하기 위하여 3개의 실험체를 제작하였으며 0.1 $f_{ck}$ . $A_{g}$의 축력을 실험이 진행되는 동안 일정하게 유지하면서, 반복가력 실험을 수행하였다. 실험결과, 유효 폭은 횡변위의 증가에 따라 증가하는 것으로 나타났으며 최대강도 발현시 h/3에 해당하는 전체 플랜지가 유효 폭으로 작용하는 것으로 나타났다. 그러므로, PCI나 국내 기준에 의한 h/10의 유효 폭은 웨브 벽체 단부에 주어진 보강상세를 갖는 벽체에 대하여 적절치 못한 것으로 사료된다..

완화된 단부 배근상세를 갖는 특수전단벽 구조시스템의 내진성능평가 (Seismic Performance of Special Shear Wall Structural System with Effectively Reduced Reinforcement Detail)

  • 천영수;이기학;이효원;박영은;송진규
    • 콘크리트학회논문집
    • /
    • 제25권3호
    • /
    • pp.271-281
    • /
    • 2013
  • 구조형식별로 구조물의 안정성 확보를 위해 KBC2009에 새로이 도입된 높이제한에 따라, 내진설계범주D에 해당되는 60 m 이상의 RC 구조물을 계획할 경우 특수전단벽을 의무적으로 사용해야 한다. 그러나 특수전단벽의 엄격한 횡보강 배근상세는 시공성 및 경제성에 부정적 영향을 미칠 것으로 예상된다. 그래서 이 연구에서는 현 규준에 따른 특수전단벽보다 완화된 배근 상세를 갖는 특수전단벽을 제안하고, 특수전단벽과의 성능 비교를 위하여 각각 두 개의 실험체를 제작하고 횡방향 반복 하중실험을 실시하였다. 또한 그 실험 결과를 반영한 보통전단벽, 특수전단벽, 완화된 특수전단벽 구조시스템의 해석모델을 설계하여 FEMA P695에 따른 방법론으로 내진성능평가를 실시하였다.

경사가 다른 3차원 산악지형에서의 풍동실험을 통한 풍속할증평가 (Estimation of Topographic Effects over 3-Dimensional Hills with Different Slopes through Wind Tunnel Tests)

  • 조강표;정명채;조기성
    • 한국전산구조공학회논문집
    • /
    • 제20권3호
    • /
    • pp.379-386
    • /
    • 2007
  • 본 논문에서는 풍동실험을 수행하여 3차원 산악지형에서의 풍속할증현상을 정량적으로 평가하고, 3차원 산악지형의 풍속할증현상에 대해 고찰하고자 한다. 풍속할증현상을 평가하기 위하여 건축구조설계기준에서 분류하고 있는 기울기에 준하여 다음의 $5.71^{\circ}, \;11.31^{\circ},\;16.70^{\circ},\;21.80^{\circ}$, 그리고 $26.57^{\circ}$의 각각 다른 경사를 가진 5가지 산악지형모형을 제작하였다. 풍동 실험결과, 다양한 위치에서 풍속할증계수가 평가되었다 풍동실험결과를 바탕으로 풍속할증영역을 산정해 보면 수평방향의 영역은 산의 전체 지역, 수직방향의 영역은 산의 높이의 3.5배로 산정되었다. 풍속할증현상은 산의 정상부에서 크게 발생하였고, 경사 I은 57%, 경사 II는 75%, 경사 III은 79%, 경사 IV는 81%, 경사V는 61%의 풍속이 증가하였다. 또한 산의 정상에서 같은 거리에 있는 풍방향의 위치보다 풍직각방향의 위치에서의 풍속이 더 크게 평가되었고 풍직각방향의 경사시작면에서 $10{\sim}30%$의 풍속이 증가하였다.