• 제목/요약/키워드: K-complex

검색결과 18,692건 처리시간 0.048초

ON NUMERICAL PROPERTIES OF COMPLEX SYMMETRIC HOUSEHOLDER MATRICES

  • Smoktunowicz, Alicja;Grabarski, Adam
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제7권2호
    • /
    • pp.51-64
    • /
    • 2003
  • Analysis is given of construction and stability of complex symmetric analogues of Householder matrices, with applications to the eigenproblem for such matrices. We investigate numerical properties of the deflation of complex symmetric matrices by using complex symmetric Householder transformations. The proposed method is very similar to the well-known deflation technique for real symmetric matrices (Cf. [16], pp. 586-595). In this paper we present an error analysis of one step of the deflation of complex symmetric matrices.

  • PDF

복소수 SVM을 이용한 목표물 식별 알고리즘 (Target Classification Algorithm Using Complex-valued Support Vector Machine)

  • 강윤정;이재일;배진호;이종현
    • 전자공학회논문지
    • /
    • 제50권4호
    • /
    • pp.182-188
    • /
    • 2013
  • 본 논문에서는 정지하고 있는 배경에서 움직이는 목표물을 식별하기 위해 PDR(pulse doppler radar)을 이용하여 수집한 복소수 신호를 처리하는 복소수 SVM(support vector machine)을 제안한다. SVM은 패턴인식 분야에서 널리 이용되나 분류에 이용되는 특징이 대부분 실수 데이터이다. 제안된 복소수 SVM은 실수 데이터, 허수 데이터 정보와 실수부와 허수부 사이의 교차 정보를 모두 이용하여 이동하는 목표물의 분류를 수행한다. 복소수 SVM을 설계하기 위해 최적화 조건 적용 시 실수축과 허수축에 대한 슬랙변수를 고려하였고, 복소수 데이터에 대한 KKT(Karush-Kuhn-Tucker) 조건을 이용하였다. 또한 복소수 거리를 이용한 RBF(radial basis function)를 커널함수로 적용하였다. 제안된 복소수 SVM의 성능을 평가하기 위해 PDR 센서로 수집된 복소 데이터를 기존의 SVM과 복소수 SVM을 이용하여 분류한 결과 기존의 SVM에 비해 복소수 SVM의 식별결과가 개와 사람 각각 8%, 10% 향상되었다.

Synthesis, Structure, and Peroxidase Activity of an Octahedral Ru(III) Complex with a Tripodal Tetraamine Ligand

  • Cho, Jang-Hoon;Kim, Kwan-Mook;Noh, Dong-Youn;Lee, Hong-In
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권11호
    • /
    • pp.3904-3908
    • /
    • 2011
  • A new octahedral Ru(III) complex with a tripodal tetraamine ligand, tpea = tris[2-(1-pyrazoyl)ethyl]amine, has been prepared and characterized. The single crystal X-ray crystallographic study of the complex revealed that the complex has a near octahedral geometry with the tetradentate ligand and two chloride ions. Peroxidase activity was examined by observing the oxidation of 2,2'-azinobis(3-ethylbenzothiazoline)-6-sulfonic acid (ABTS) with hydrogen peroxide in the presence of the complex. Amount of $ABTS^{+{\bullet}}$ generated during the reaction was monitored by UV/VIS and EPR spectroscopies. After the initiation of the peroxidase reaction, $ABTS^{+{\bullet}}$ concentration increases and then decreases after certain time, indicating that both ABTS and $ABTS^{+{\bullet}}$ are the substrates of the peroxidase activity of the Ru(III) complex.

Pine Needle Oil and Korean Medicinal Herb Complex Protect Hyperlipidemia and Liver Cell Damage Induced by Alcohol

  • Park, Kap-Joo;Kim, Kang-Sung;Ahn, Ki-Heung;Rhee, Joon-Shick
    • 환경생물
    • /
    • 제21권4호
    • /
    • pp.410-414
    • /
    • 2003
  • The effect of treatment with pine needle oil complex (complex of pine needle oil and Korean medicinal herbs) upon rat hepatocytes exposed to alcohol was investigated. We compared body weight gain and ratios of liver and kidney to body weight and the serum biochemistry of rats administered both alcohol and Pine needle oil complex to control rats treated with alcohol alone. Pine needle oil complex treatment resulted in a significant reduction in the levels of aspartate aminotransferase (AST), alanine aminotransferase (ALT) and triglycerides (TG) compared to the control rats. These data suggest that Pine needle oil complex represents an excellent candidate for protection of rat hepatocytes from alcohol-mediated damage.

Coenzyme Complex Decreased Cardiotoxicity When Combined with Chemotherapy in Treating Elderly Patients with Gastrointestinal Cancer

  • Zhang, Hai-Yan;Lu, Xiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권9호
    • /
    • pp.4045-4049
    • /
    • 2015
  • Objective: To investigate the effect of coenzyme complex on decreasing cardiotoxicity in elderly patients with gastrointestinal cancer who were treated by chemotherapy. Methods: From September 2011 to February 2015, we recruited 54 elderly (with more than 70 years of age) patients with gastrointestinal cancer, with advanced disease. Then treated with chemotherapy combined with or without coenzyme complex. After two cycles of treatment, the effect of coenzyme complex on decreasing cardiotoxicity were evaluated. Results: Chemotherapy was combined with coenzyme complex in 32 patients (22man, 10 woman; median age: 74 years, range: 70-87 years) without coenzyme complex in 22 patients (15man, 7 woman; median age: 73 years, range: 70-80 years) with gastrointestinal cancer. Cardiac event was significantly lower in patients treated with chemotherapy combined with coenzyme complex (p<0.01). Conclusions: Coenzyme Complex decreased cardiotoxicity when combined with chemotherapy in treating elderly patients with gastrointestinal cancer.

KSLV-I 조립콤플렉스 시스템 설계 (KSLV-I Assembly Complex System Design)

  • 진승보;박정주
    • 시스템엔지니어링학술지
    • /
    • 제2권1호
    • /
    • pp.37-41
    • /
    • 2006
  • The KSLV-I satellite launch vehicle will be launched in a space center currently under construction. The Space Center which is an advance post base of space development of Korea is located on Oenaro island in Kohung, South Cholla Province. A Ground Complex of the Space Center consists of an AC(Assembly Complex), a LC(Launch Complex), and a MCC(Mission Control Center). Assembly and test facilities are located in the AC in which stage assembly, integrated assembly, check-up, certification test, and pre-launch test are made effectively. A launch pad, fuel supply facilities, a launch control center and associated supporting facilities are located in the LC, and the MCC has control over the space center. These ground complex facilities have diverse forms of an interface with mechanical device, electric device, and etc. These should also provide optimum condition and performance during launch operation processes of the launch vehicle. This paper introduces the result of R&D for the AC of the ground complex performed during system design period.

  • PDF

Norfloxacin과 ${\beta}-Cyclodextrin$간의 Inclusion Complex에 관한 약제학적 연구 (Pharmaceutical Studies on Inclusion Complex of Norfloxacin with ${\beta}-Cyclodextrin$)

  • 지웅길;박목순;권중무
    • Journal of Pharmaceutical Investigation
    • /
    • 제17권1호
    • /
    • pp.1-14
    • /
    • 1987
  • To increase the bioavailability of norfloxacin, inclusion complex of antimicrobial agent norfloxacin with ${\beta}-Cyclodextrin$ was prepared and studied by the solubility method, spectrophotometric methods(UV, IR, $^1H-NMR$), differential thermal analysis, powder X-ray diffractometry, the physical properties, the antimicrobial activity, DNA binding and in situ recirculation technique. The conclusions are summerized as following; 1) The inclusion complexation was identified by means of solubility, spectrophotometry(UV, IR, NMR), DTA and X-ray diffraction. 2) The molar ratio of $norfloxacin-{\beta}-cyclodextrin$ complex was 1 : 1. 3) The stability constant of $norfloxacin-{\beta}-cyclodextrin$ complex was $21.5\;M^{-1}$, and both true and apparent partition coefficients of the inclusion complex were larger than those of norfloxacin. 4) The time required to dissolve 60% $(T_{60}%)$ of the inclusion complex was 120 min. in distilled water and in the artificial intestinal juice, while norfloxacin did not reach to 60% dissolution within 120 min. 5) The antimicrobial activity of the inclusion complex against Pseudomonas aeruginosa, Klebsiella pneumoniae and Staphylococcus aureus showed no significant difference compared to that of norfloxacin alone. 6) Studies on binding properties between the inclusion complex and norfloxacin alone to DNA according to equilibrium dialysis showed no significant differency. 7) In situ absorption rates (Ka) of inclusion complex and norfloxacin alone were 0.229 and $0.102hr^{-1}$, respectively.

  • PDF

도시 지역에서 아파트 단지가 흐름과 확산에 미치는 영향 (Effects of an Apartment Complex on Flow and Dispersion in an Urban Area)

  • 이영수;김재진
    • 대기
    • /
    • 제21권1호
    • /
    • pp.95-108
    • /
    • 2011
  • The effects of an apartment complex on flow and pollutant dispersion in an urban area are numerically investigated using a computational fluid dynamics (CFD) model. The CFD model is based on the Reynolds-averaged Navier-Stokes equations and includes the renormalization group k-${\varepsilon}$ turbulence model. The geographic information system (GIS) data is used as an input data of the CFD model. Eight numerical simulations are carried out for different inflow directions and, for each inflow direction, the effects of an apartment complex are investigated, comparing the characteristics of flow and dispersion before and after construction of the apartment complex in detail. The observation data of automatic weather system (AWS) is analyzed. The windrose analysis shows that the wind speed and direction after the construction of the complex are quite different from those before the construction. The construction of the apartment complex resulted in the decrease in wind speed at the downwind region. It is also shown that the wind speed increased partially inside the apartment complex due to the channeling effect to satisfy the mass continuity. On the whole, the wind speed decreased at the downwind region due to the drag effect by the apartment complex. As a result, the passive pollutant concentration increased (decreased) near the downwind region of (within) the apartment complex compared with that before the construction.

시흥·안산 산단 및 영향지역의 휘발성유기화합물질(VOCs) 분포 특성 (Distribution Characteristics of Volatile Organic Compounds (VOCs) in an Industrial Complex and in Affected Areas in Siheung and Ansan)

  • 김동기;우정식;한현수;김용준;김웅수;홍순모;김종수;윤미혜
    • 한국환경보건학회지
    • /
    • 제46권3호
    • /
    • pp.256-266
    • /
    • 2020
  • Objectives: The concentrations and distribution characteristics of volatile organic compounds (VOCs) in an industrial complex and surrouding affected residential areas were investigated in an effort to support the efficient management of VOCs. Methods: The atmospheric concentrations of VOCs were analyzed at sites around the Sihwa-Banwol complex located in the cities of Siheung and Ansan and in the surrounding affected residential areas. The appearance of VOCs and the characteristics of their temporal and spatial distribution were evaluated. Results: The total VOC concentrations in the industrial complex were detected at 1.9-2.3 times higher than in the affected areas, but the daily VOCs distributions showed similar patterns in both sites. In particular, it was confirmed that the composition ratio of the VOCs and concentration fluctuations over time in the affected areas are similar to those in the adjacent industrial complex. VOC levels in the affected areas were higher than in residential areas in cities without an industrial complex. Conclusions: VOCs in residential areas near an industrial complex were highly distributed due to the influence of continuous pollutant emissions from the industrial complex. Therefore, the management of VOCs in the atmosphere of the affected area is important for identifying and managing the sources of VOCs detected in high concentrations in the industrial complex.

Cu(II)-Chitosan Complex의 DFP 분해 반응 연구 (A Study on the Decomposition of DFP using Cu(II)-Chitosan Complex)

  • 계영식;정우영;김동욱;박양기;송시욱;정근홍
    • 한국군사과학기술학회지
    • /
    • 제15권5호
    • /
    • pp.699-704
    • /
    • 2012
  • In this study, we have proposed a novel decomposition agent composed of Cu(II) and soluble chitosan for organophosphorus chemical agents. Compared to the autohydrolysis, the soluble Cu(II)-Chitosan complex hydrolyzed DFP more effectively. Results show that soluble Cu(II)-Chitosan complex enhances the hydrolysis of DFP in 4~6 folds compared to the autohydrolysis of DFP in buffer solution. This study provides the possibility of using this soluble Cu(II)-Chitosan complex as the environmental friendly decomposition agent which can substitute current DS-2 decomposition agent.