• Title/Summary/Keyword: J-Inverter

Search Result 406, Processing Time 0.027 seconds

Predictive Instantaneous Control of inverter for UPS (UPS용 예측 순시제어형 인버터)

  • Kim, B.J.;Kim, J.H.;Cho, J.H.;Kim, J.S.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.237-239
    • /
    • 1995
  • The inverter for UPS system is required to satisfy pure sinusoidal output voltage with very low THD(Total Harmonic distortion). This paper proposes a TMS320c31 digital signal processor based predictive instantaneous control scheme of inverter. The proposed scheme is able to satisfy the conditions; high capability, high efficiency, low audible noise and robustness of inverter. The transient state characteristics of proposed inverter has been improved. in case of power failure or recovery, nonlinear load, sudden load change or parameters variations. Finally, the performance of the proposed inverter is shown and discussed by simulation and experiment.

  • PDF

Study on Grid-Connected Photovoltaic System using Current-Source Inverter (전류형 인버터를 이용한 계통 연계형 태양광 발전 시스템에 관한 연구)

  • Lim, J.M.;Park, S.J.;Lee, S.H.;Moon, C.J.;Choi, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.677-681
    • /
    • 2005
  • This Paper presents a 6 pulse shift operation control mode of current-source-inverter to make improvement of efficiency and to reduce the frequency of inverter switching for photovoltaic generation system using PWM current-source-inverter. This system is connected solar cell energy directly without using a storage cell. The proposed circuit can maintain maximum voltage of photovoltaic generation of take advantage of six Buck-Boost converter and a full-bridge inverter determines the polarity of AC output. That is controlled by using digital signal processor TMS320F2812 for operation about a 6 pulse shift operation control of current-source-inverter, and it is verified through the experimental results.

  • PDF

Multi-level PWM Inverter Considering the number of Output Voltage level and Current rating (출력전압 레벨 수와 전류정격을 고려한 PWM 다중레벨 인버터)

  • Park, N.S.;Seo, J.J.;Park, S.J.;Kim, K.H.;Cho, S.E.;Kim, C.U.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.659-662
    • /
    • 2005
  • In this paper, we proposed the novel hybrid multi-level inverter using combination of the output voltage of transformers to reduce the THD(Total Harmonic Distortion) and improve the waveform of output voltage. The proposed multi-level inverter used the output of transformer which is 1times, 2times, 4times of input of the transformers. So we increased the output voltage from the reduce the number of switching component and transformer. Also, we tested the proposed prototype 15-level inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed multi -level PWM inverter.

  • PDF

PWM Inverter Controller Design for UPS(Uninterruptible Power Supply) Using a DSP(TMS320F240) (DSP(TMS320F240)을 이용한 무정전 전원장치(UPS)용 PWM 인버터 제어기 설계)

  • Jang, J.Y.;Lee, J.P.;Choi, J.Y.;Choy, I.;Lee, S.C.;Yoo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2587-2589
    • /
    • 1999
  • In this paper, we propose a new control scheme for a PWM inverter using digital control. Digital control has various advantages in comparison with conventional analogue control. It can achieve high frequency switching of inverter and can be little influenced for temperature variations and aging of devices. This digitally-controlled PWM inverter is implemented using a Digital Signal Processor(DSPTMS320F240). The simulation results are given to verify the DSP based PWM inverter design and implementation.

  • PDF

A Study on the Novel Time Sharing Type Current Fad High Frequency Resonant Inverter (새로운 시분할 방식 전류형 고주파 인버터에 관한 연구)

  • Kim H.J.;Won J.S.;Kang J.W.;Cho G.P.;Oh S.H.;Min B.J.;Jung D.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.27-30
    • /
    • 2003
  • This paper describes two novel current fed high frequency resonant inverter can be used as the power supp]y for wax-sealing. This two topology can be obtained higher output frequency than switching frequency by composing modified unit inverter based on conventional half-bridge serial resonant inverter in parallel with input power source. also, By using time-sharing gate control method, this proposed inverter can not only realize the output control of dependence irrespective of the switching frequency using phase-shift but also reduce switching loss because it has ZVS function. Simulation results through the Pspice have demonstrated the feasibility of the proposed inverter. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF

The Study of a Hairpin Line Resonator Filter Design by Using a J Inverter (J 인버터를 이용한 Hairpin Line 필터설계 연구)

  • 오데레사
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.4
    • /
    • pp.589-594
    • /
    • 2002
  • The filter of hairpin type can be designed small but has a demerit which a design method is complex. This paper suggests the method that a hairpin line filter is designed with applying a transmission line method and J inverter circuit, accurately calculated the J value and the b parameter. It is considered about the line have no the mutual coupling element with next line to each other. is calculated a length of electric coupling line about coupling element in each inverter stage from the J value and the b parameter. In order to show the validity of the proposed design method, band pass filter of small hairpin line is designed at center frequency 2.6 GHz, with Serenade 8.0 software tool and the simulation characteristics are compared with design results.

A New Quasi-Resonant M Link Inverter (새로운 Quasi-Resonant DC Link 인버터)

  • Lee, J.J.;Lee, J.W.;Park, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.328-331
    • /
    • 1990
  • A new quasi-resonant do link inverter is suggested, which can operate at the constant peak do link voltage irrespective of the magnitude of load current. The inverter is analyzed by using the topological analogy between the proposed inverter and the resonant DC/DC converter. Based on the analysis, an appropriate current controller is developed, which results in low current stress to the resonant capacitor and also enjoys the inherent capability of the current initialization of resonant inductor. For the purpose of confirming the inverter characteristics, some simulation results are presented.

  • PDF

THD Reduction by Using HBML-PWM Hybrid Type Inverter (HBML-PWM 혼용 인버터를 이용한 THD 저감)

  • Yi, Tao;Moon, C.J.;Song, S.G.;Park, S.J.;Cho, S.E.;Kim, J.D.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.655-658
    • /
    • 2005
  • In this paper, we proposed the electric circuit using one common arm of H-Bridge Inverters to reduce the number of switching component in multi-level inverter combined with H-Bridge Inverters and Transformers. and furthermore we suggested the new multi-level PWU inverter using PWM level to reduce THD(Total Harmonic Distortion). and we used the switching method that can be same rate of usage at each transformer. Also, we tested the proposed prototype 9-level inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed multi-level PWM inverter.

  • PDF

Experimental Study on the Cooling seasonal Performance Factor of Room Air-conditioner (에어컨의 냉방기간 에너지 효율 산출을 위한 실험적 연구)

  • Lee, H.W.;Moon, J.H.;Bae, Y.D.;Park, J.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.204-216
    • /
    • 1992
  • In most cases, EER(Energy Efficiency Ratio) is available to present energy efficiency of air-conditioners. But, EER is not adapt to measure energy efficiency at actual life environment because it is based on fixed temperature and humidity contditions. To overcome this disadvantage, there is need to introduce SEER(Seasonal Energy Efficiency Ratio) established at time varient temperature and humidity conditions. In this paper, SEER measurement method and conditions based on actual life environment of the country is introduced, and discussed SEER value about two air-conditioner type, that is, non inverter air-conditioner and inverter air-conditioner. As a result of, inverter air-conditioner was superior to non inverter air-conditioner at cooling seasonal energy efficiency.

  • PDF

3-phase IHCML inverter using common-arm (공통암 3상 IHMCL 인버터)

  • Song, S.G.;Park, S.J.;Moon, C.J.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.512-514
    • /
    • 2007
  • The number of transformers and the size of transformers in inverter using 3-phase transformer could be reduced compare with a multi-level inverter using single phase transformer. but still the 3-phase transformer inverter needs many switches. In this study, we proposed the isolated multi-level inverter using 3-phase transformers and common arm. Also, the equal-area method is used to calculate conduction angle with switching frequency equal to output fundamental frequency and it can reduce harmonics component of output voltage and switching loss. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.

  • PDF