• Title/Summary/Keyword: Iron sample

Search Result 283, Processing Time 0.03 seconds

M ssbauer Study and Atomic Migration in MgFe2O4

  • Lee, Seung Wha;Yoon, Sung Hyun;An, Sung Yong;Kim, Woo Chul;Kim, Chul Sung
    • Journal of Magnetics
    • /
    • v.4 no.4
    • /
    • pp.115-118
    • /
    • 1999
  • $MgFe_2O_4$ has been studied with X-ray diffraction, M ssbauer spectroscopy and vibration sample magnetometer (VSM). The crystal structure of the sample is found to have a cubic spinel structure with a lattice constant of $a_0=8.390$\pm$0.005$\AA$.$ The iron ions at both A (tetrahedral) and B (octahedral)sites are found to be in ferric high-spin states. Its Neel temperature TN is found to be 710$\pm$3 K. The Debye temperature for the A and B sites found to be 417$\pm$5 K and 331$\pm$5 K., respectively. Atomic migation from the A to the B sites starts near 425 K and increases rapidly with increasing temperature to such a degree that 31% of the ferric ions at the A sites have moved over to the B sites by 600 K.

  • PDF

Direct acid Leaching of zinc from Marmatite ores 2 Kinetics of Autoclave Leaching of Synthetic ${\beta}$-ZnS (Marmatite 鑛의 直接酸浸出에 關한 硏究 (第2報) ${\beta}$-ZnS Autoclave Leaching의 反應機構에 關한 硏究)

  • Kim Jae Won
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.1
    • /
    • pp.33-37
    • /
    • 1967
  • The influence of impurities contained in Marmatite ores on leaching of zinc was investigated. The zinc sulfide having the same crystal structure of natural Sphalerite was prepared by heating the zinc sulfide chemically precipitated, at $650^{\circ}C$ in nitrogen atmosphere. The activation energy of the sample was 25.8 kcal per mole in the leach test when oxygen partial pressure was 5 atm. and the value was exceedingly high compared to that obtained in Marmatite ores. Synthetic zinc sulfides added with small amount of each impurities were treated in same procedure. As a result, it was found that the leaching velocity was accelerated sharply when about 1 percent of $Cu^{++}$ was blended to the sample. Larger amount of iron has also same effect but the effect was minor compared to the copper. The other impurities indicated no appreciable catalytic action.

  • PDF

Development of a Mushroom Powder Certified Reference Material for Element Analysis

  • Betru, Tegegn Gizachew;Yim, Yong-Hyeon;Lee, Kyoung-Seok
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.108-112
    • /
    • 2020
  • A certified reference material (CRM) for the analysis of nutrient elements in an edible mushroom (Ganoderma lyceum) powder has been developed (KRISS CRM 108-10-011). The mass fractions of calcium (Ca), iron (Fe), and zinc (Zn) were measured by isotope dilution inductively coupled plasma mass spectrometry (ID ICP/MS). To dissolve the fungi cell wall of mushroom consisted of chitin fibers, sample preparation method by single reaction chamber type microwave-assisted acid digestion with acid mixtures was optimized. The mean measurement results obtained from 12 sample bottles were used to assign as the certified values for the CRM and the between-bottle homogeneities were evaluated from the relative standard deviations. The certified values were metrologically traceable to the definition of the kilogram in the International System of Units (SI). This CRM is expected to be used for validation of analytical methods or quality control of measurement results in analytical laboratories when they determine the mass fractions of elements in mushroom or other similar samples.

L-lysine and L-arginine inhibit the oxidation of lipids and proteins of emulsion sausage by chelating iron ion and scavenging radical

  • Xu, Peng;Zheng, Yadong;Zhu, Xiaoxu;Li, Shiyi;Zhou, Cunliu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.6
    • /
    • pp.905-913
    • /
    • 2018
  • Objective: To evaluate the effects of L-lysine (Lys)/L-arginine (Arg) on lipid and protein oxidation of emulsion sausage during storage and its possible mechanism. Methods: Four samples were prepared based on the presence or absence of additional sodium isoascorbate, Lys, or Arg: sample A (control), sample B (0.05 g of sodium isoascorbate), sample C (0.4 g of Lys), and sample D (0.4 g of Arg). Peroxide value (POV), thiobarbituric reactive substances (TBARS), protein carbonyls and thiols were measured. 2,2-Diphenyl-1-picrylhydrazyl (DPPH) and hydroxyl radical-scavenging, ferrous ion-chelating ability were also measured. Results: Compared with the control, the sample treated with sodium isoascorbate, Lys or Arg had significantly lower POV during the initial 20 days, TBARS during the initial 15 days. Protein carbonyls were significantly lower compared Sample B, C, and D with A during the later storage (10 to 25 days); basically, protein thiols became lower during storage when the samples were treated with sodium isoascorbate, Lys, or Arg. Both Lys and Arg had weak reducing power but strong ferrous ion-chelating activity and DPPH radical- and hydroxyl radical-scavenging activity. Conclusion: Both Lys and Arg effectively inhibited the oxidation of lipids and proteins in emulsion sausage by scavenging free radicals and chelating ferrous ions. The results obtained may be favorable for the prevention of lipid and protein oxidation during processing and storage of meat products.

Evaluation of Internal Resistance in Asphalt Concretes

  • Zandi, Yousef;Akpinar, Muhammet Vefa
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.247-250
    • /
    • 2012
  • Composites are somewhat more difficult to model than an isotropic material such as iron or steel due to the fact that each layer may have different orthotropic material properties. In finite element literature the asphalt mixes are represented by using rectangular meshes, not the actual picture of their cross-sections. Asphalt aggregate size and distribution in the asphalt concrete sample, aggregate shape, and fractured surface effects are ignored. In this research, the actual image of the sample including all these effects were directly considered in the finite element. The samples, were cut into cross-sections and were scanned. The image-processing toolbox of Labview was utilized in obtaining the rectangular gray images of the scanned images. In the rectangular sample the aggregates were white and the asphalt binders were black. The grayscale images were converted by LABVIEW into the format required by ANSYS as an input file, with the same dimensions. The nodes at the bottom of the model were constrained in both x and y directions. Left and right edges were symmetry and top was free. Certain amount of pressure was applied along the top surface to simulate the tire pressure.

CORROSION CHARACTERISTICS BETWEEN IMPLANT FIXTURE AND ABUTMENT SCREW (임플랜트 고정체와 지대나사간의 부식특성에 관한 연구)

  • Kee, Su-Jin;Kweon, Hyeog-Sin;Choe, Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.85-97
    • /
    • 2000
  • The purpose of this study was to compare the corrosion characteristics between implant fixture and two types of abutment screw ; gold screw, titanium screw. The anodic polarization behavior, the galvanic corrosion behavior, and the crevice corrosion behavior of prepared samples were investigated using potentiostat and scanning electron microscope. The results were as follows: 1. Anodic polarization behavior of samples; The primary passivation potential of implant fixture was -420mV, implant abutment was -560mV. titanium screw was -370mV and gold screw was -230mV. All samples were shown to have a high corrosion potential and good formation of passive film. The critical passive current density of gold screw was higher than that of other samples and the sample of gold screw showed a unstable passive film formation at passive region. 2. Galvanic corrosion behavior of samples; Contact current density between implant fixture and titanium screw showed $8.023{\times}10^{-5}C/cm^2$. Contact current density between implant fixture and gold screw showed $5.142{\times}10^{-5}C/cm^2$. 3. Crevice corrosion behavior of samples; The crevice corrosion resistance of sample using titanium screw was higher than that of sample using gold screw, and a severe corrosion morphologies were observed at the fixture-screw interface by the scanning electron microscope.

  • PDF

Reaction Kinetics with Hydrogen and Temperature Dependence of the Hydriding Rate for a Magnesium-Based Nickel Iron Oxide Alloy

  • Song, Myoung Youp;Baek, Sung Hwan;Park, Hye Ryoung
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.6
    • /
    • pp.463-468
    • /
    • 2012
  • A 71.5 wt%Mg-23.5 wt%Ni-5 wt%$Fe_2O_3$ (Mg-23.5Ni-$5Fe_2O_3$) sample was prepared by a quite simple process, reactive mechanical grinding, and its hydriding and dehydriding properties were then investigated. The reactive mechanical grinding of Mg with Ni and $Fe_2O_3$ is considered to facilitate nucleation and shorten the diffusion distances of the hydrogen atoms. After the hydriding-dehydriding cycling, the Mg-23.5Ni-$5Fe_2O_3$ sample contained $Mg_2Ni$ phase. Expansion and contraction of the hydride-forming materials (Mg and $Mg_2Ni$) with the hydriding and dehydriding reactions are also considered to increase the hydriding and dehydriding rates of the mixture by forming defects and cracks leading to the fragmentation of the particles. The temperature dependence of the hydriding rate of the sample is discussed.

Investigation of an Acceptable Hemolysis Index Using Re-collected Samples (재채혈된 검체를 이용한 허용 Hemolysis Index에 대한 연구)

  • Hong Bum KIM;Dong Il WON;Kyoung Ae SON;Jin Man KIM;Yu Jin WOO
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.1
    • /
    • pp.32-42
    • /
    • 2024
  • This study compared the results of hemolyzed samples and re-collected samples to investigate a hemolysis influence and an acceptable hemolysis index (HI). Before and after hemolysis, alkaline phosphatase (ALP), aspartate aminotransferase (AST), alanine aminotransferase (ALT), amylase (Amy), direct bilirubin (D-bil), total bilirubin (T-bil), creatine phosphokinase (CK), gamma glutamyl transferase (GGT), iron, potassium (K), lactate dehydrogenase (LDH), magnesium (Mg), phosphorus (Phos), total protein (TP), and uric acid (UA) showed significant results in the paired t-test. LDH, K, iron, AST, CK, GGT, TP, Amy and Phos had a high correlation between the degree of hemolysis and the results of samples. When comparing Roche's cut-off HI with HIQChigh obtained using quality control (QC) high standard deviation (SD), AST, D-bil, CK, and LDH were similar, but Amy, GGT, K, iron, Phos, and TP were lower than the cut-off HI of Roche, while ALP and ALT were higher. Some analytes which showed no significant results in the paired t-test, were found to have significant results in HI>200. Hence, it is suggested that the hemolyzed sample should be rejected if HI>200. Based on this study that some analytes were affected when HI<100, we recommend to set the standard of hemolysis starting from HI>50.

Effect of Spinning Speed on 29Si and 27Al Solid-state MAS NMR Spectra for Iron-bearing Silicate Glasses (시료의 회전 속도가 함철 비정질 규산염의 고상 NMR 신호에 미치는 영향)

  • Kim, Hyo-Im;Lee, Sung Keun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.295-306
    • /
    • 2018
  • Despite the utility of solid-state NMR, NMR studies of iron-bearing silicate glasses remain a challenge because the variations in the peak position and width with increasing iron content reflect both paramagnetic effect and iron-induced structural changes. Therefore, it is essential to elucidate the effect of temperature on the NMR signal for iron-bearing silicate glasses. Here, we report the $^{29}Si$ and $^{27}Al$ MAS NMR spectra for $(Mg_{0.95}Fe_{0.05})SiO_3$ and $Fe_2O_3$-bearing $CaAl_2Si_2O_8$ (anorthite) glasses with varying spinning speed to interpret the NMR spectra for iron-bearing silicate glasses. The increase in the spinning speed results in an increase in the sample temperature. The current NMR results allow us to understand the origins of the changes in NMR signal with increasing iron content and to provide information on the dipolar interaction between nuclear spins. The $^{29}Si$ NMR spectra for $(Mg_{0.95}Fe_{0.05})SiO_3$ glass and $^{27}Al$ NMR spectra for $Fe_2O_3$-bearing $CaAl_2Si_2O_8$ glasses show that the peak shape and position of iron-bearing glasses do not change with increasing spinning speed up to 30 kHz. These results suggest that the NMR signal in the Fe-bearing glasses may stem from the 'survived nuclear spins' beyond the cutoff radius from the Fe, not from the paramagnetic shift. Based on the current results, the observed apparent shifts toward lower frequency of Al peak for $Fe_2O_3$-bearing $CaAl_2Si_2O_8$ glasses with increasing $Fe_2O_3$ at all spinning speed (15 kHz to 30 kHz) indicate the increase in the fraction of ${Q^4}_{Al}$(nSi) with lower n (i.e., 1 or 2) with increasing $Fe_2O_3$ and the spatial proximity between Fe and ${Q^4}_{Al}$(nSi) with higher n (i.e., 3 or 4). The present results show that changes in the NMR signal for iron-bearing silicate glasses reflect the actual iron-induced structural changes. Thus, it is clear that the applications of solid-state NMR for iron-bearing silicate glasses hold strong promise for unraveling the atomic structure of natural silicate glasses.

The Effects of Gobongeonyangdan on the sex hormones and hematogenesis in rats (고본건양단(固本健陽丹)이 백서(白鼠)의 성(性)호르몬 및 조혈기능(造血機能)에 미치는 영향(影響))

  • Im, Hong-Woo;Kang, Seok-Bong
    • THE JOURNAL OF KOREAN ORIENTAL ONCOLOGY
    • /
    • v.4 no.1
    • /
    • pp.55-70
    • /
    • 1998
  • It has been known that "Gobongeonyangdan" has a certain effects on male sterility in the field of oriental medicine. This thesis purposes to prove such effects of the medicine especially concerning sex hormones and hematogenesis. In the study were used three groups of rats: two of those were treated with Gobongeonyangdan with a variety of quantity and the other untreated. The experiment spans for 35 days: tests upon those subjects were done three times on the 7th, 21st, and 35th day checking the change of testosterone, estradiol, LH, FSH and iron in the serums, and RBC, hematocrit and hemoglobin levels. The results obtained from the study are as follows: 1. The content of testosterone in the serums marked a significant increase in both treated groups in comparison to the untreated group. 2. The content of estradiol in the serums showed a significant increase in the treated groups as to the untreated. 3. The content of LH in the serums increased significantly in the treated groups as to the untreated. 4. The content of FSH in the serums also increased remarkably in the two treated groups as to the untreated. 5. The content of iron in the serum was seen to be increased in the treated groups rather than the untreated group. 6. The RBC was observed to show a tendency toward a significant increase in both the treated groups in comparison with the untreated group. 7. The hemoglobin levels were also increased significantly in the treated groups as to the untreated. 8. The hematocrit levels were decreased significantly in one of the two treated group(sample A group) and there was no difference in the other group(sample B group) in comparison with the untreated group. Consequently, "Gobongeonyangdan" may well be a favorable medicine for patients two have sexual functional disorder and it is also effective on hematogenesis.

  • PDF