Evaluation of Spatial Dose Rate in Working Environment during Non-Destructive Testing using Radioactive Isotopes (방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 공간선량률 평가)

  • Cho, Yong-In;Kim, Jung-Hoon;Bae, Sang-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.373-379
    • /
    • 2022
  • The radiation source used for non-destructive testing have permeability and cause a scattered radiation through collisions of surrounding materials, which causes changes in the surrounding spatial dose. Therefore, this study attempted to evaluate and analyze the distribution of spatial dose by source in the working environment during the non-destructive test using monte carlo simulation. In this study, Using FLUKA, a simulation code, simulates 60Co, 192Ir, and 75Se source used in non-destructive testing, The reliability of the source term was secured by comparing the calculated dose rate with the data of the Health and Physics Association. After that, a non-destructive test in the radiation safety facility(RT-room) was designed to evaluate the spatial dose according to the distance from the source. As a result of the spatial dose evaluation, 75Se source showed the lowest dose distribution in the frontal position and 60Co source showed a dose rate of about 15 times higher than that of 75Se and about 2 times higher than that of 192Ir. In addition, the spatial dose according to the distance tends to decrease according to the distance inverse square law as the distance from the source increases. Exceptionally, 60Co, 192Ir, and 75Se sources confirmed a slight increase within 2 m of position. Based on the results of this study, it is believed that it will be used as supplementary data for safety management of workers in radiation safety facilities during non-destructive testing using radioactive isotopes.

Evaluation of Absorbed Dose According to the Gold Nanoparticle Density in Prostate Cancer Brachytherapy (전립선암의 근접치료 시 금 나노입자 밀도에 따른 흡수선량평가)

  • Lee, Deuk-Hee;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.247-252
    • /
    • 2019
  • This study was evaluated absorbed dose according to the gold nanoparticle density in prostate brachytherapy which was constantly occurred in Korean men. Absorbed dose evaluation was using MCNPX program which was applied Monte Carlo simulation. Source were applied $^{192}Ir$ which was temporary insertion source and $^{103}Pd$ which was permanently insertion source. And gold nanoparticle density was applied 0 mg, 7 mg, 18 mg and 30 mg. The prostate absorbed dose was increased in proportion to the density 2.95E-14 Gy/e to 4.42E-14 Gy/e in $^{192}Ir$ and showed the same tendency in $^{103}Pd$. And surrounding organ absorbed dose was inversely proportional to the density. Therefore using nanoparticle in brachytherapy was increased therapeutic ratio.

Assessment of Radiation Dose for Surrounding Organs and Persons Approaching Patients upon Brachytherapy of Cervical Cancer with $^{192}Ir$ ($^{192}Ir$를 사용한 자궁경부암 치료시 주변 장기 및 근접한 사람의 선량 평가)

  • Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.283-288
    • /
    • 2010
  • In order to evaluate radiation dose on the uterus and surrounding organs during brachytherapy for cervical cancer, of which the frequency of occurrence is high in Korean women, as well as radiation dose on medical staffs in proximity of patients receiving the therapy, a mathematical phantom based on reference Korean was established and the radiation dose was calculated accordingly. For simulation, $^{192}Ir$, which is useful in brachytherapy, was selected as radionuclide. Also, it was presumed that the intensity of initial radiation was 1 Ci. The result indicated the radiation of 4.92E-14 Gy/Ci in the uterus, the source organ. In addition, radiation on people around patient receiving the therapy was found to be 1.24E-07 Sv at a distance of 30 cm.

Development of Real-Time Thickness Measuring System for Insulated Pipeline Using Gamma-ray (감마선을 이용한 단열배관의 실시간 두께측정시스템 개발)

  • Jang, Ji-Hoon;Kim, Byung-Joo;Kim, Gi-Dong;Cho, Kyung-Shik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.500-507
    • /
    • 2002
  • By this study, on-line real-time radiometric system was developed using a 64 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses an Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer through cable. This system collects and analyses the data from the detector array in real-time as the crawler travels over the piping system. The maximum measurable length of pipe is 120cm/min. in the case of 1mm scanning interval.

Ir-192 100 ci용 조사기 열 시험

  • 방경식;이주찬;김동학;이재호;서기석
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.434-434
    • /
    • 2004
  • 하나로에서 생산되는 방사성 동위원소를 생산단계에서 소비단계까지의 유통체계를 확립하기 위해서는 방사성동위원소를 안전하게 운반하기 위한 운반용기를 개발하여야 한다. 따라서, 원자력연구소에서는 Ir-192 110 ci용 밀봉선원 조사기를 개발하고 있다. 이 조사기는 국내ㆍ외 방사성물질 운반용기관련 법규의 운반용기 분류기준에 의하면 B형 운반용기로 분류된다. B형 운반용기는 관련법규에서 규정하고 있는 $800^{\circ}C$ 열 조건에서 30분 이상 동안 견딜 수 있는 능력을 갖추어야 한다.(중략)

  • PDF

Dose assessment of HDR intracavitary brachytherapy using different sources (강내 근접치료에 사용되는 고선량률 Ir-192선원에 따른 치료계획시스템의 선량평가)

  • Yang, Oh-Nam;Lim, Chung-Hwan;Kim, Dae-Yong;Choi, Won-Sik;Shin, Sung-Soo;Ahn, Woo-Sang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.205-206
    • /
    • 2013
  • 자궁경부암 근접치료를 시행했던 환자 10명을 대상으로 동일한 처방에 대한 기하학적 특성이 다른 Ir-192선원을 치료계획시스템을 이용하여 선량평가를 비교 분석 해 보았다.

  • PDF

Development and Application of Test Apparatus for Classification of Sealed Source (밀봉선원의 성능시험을 위한 장치 개발 및 적용)

  • Kim, Dong-Hak;Seo, Ki-Seog;Bang, Kyoung-Sik;Lee, Ju-Chan;Son, Kwang-Je
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.35-44
    • /
    • 2007
  • Sealed sources have to conducted the tests be done according to the classification requirements for their typical usages in accordance with the relevant domestic notice standard and ISO 2919. After each test, the source shall be examined visually for loss of integrity and pass an appropriate leakage test. Tests to class a sealed source are temperature, external pressure, impact, vibration and puncture test. The environmental test conditions for tests with class numbers are arranged in increasing order of severity. In this study, the apparatus of tests, except the vibration test, were developed and applied to three kinds of sealed source. The conditions of the tests to class a sealed source were stated and the difference between the domestic notice standard and ISO 2919 were considered. And apparatus of the tests were made. Using developed apparatus we conducted the tests for $^{192}Ir$ brachytherapy sealed source and two kinds of sealed source for industrial radiography. $^{192}Ir$ brachytherapy sealed source is classified by temperature class 5, external pressure class 3, impact class 2 and vibration and puncture class 1. Two kinds of sealed source for industrial radiography are classified by temperature class 4, external pressure class 2, impact and puncture class 5 and vibration class 1. After the tests, Liquid nitrogen bubble test and vacuum bubble test were done to evaluate the safety of the sealed sources.