• Title/Summary/Keyword: Ion concentration and type

Search Result 288, Processing Time 0.055 seconds

Effect of Copper ion on Xanthine Oxidase Activity and Type Conversion (Xanthine oxidase 활성 및 형전환에 미치는 구리이온의 영향)

  • Huh, Keun;Lee, Sang-Il;Park, Jeen-Woo
    • YAKHAK HOEJI
    • /
    • v.38 no.2
    • /
    • pp.211-217
    • /
    • 1994
  • Copper intoxication and disturbance of copper metabolism induced various oxygen-derived free radicals related damages. The effect of copper ion on xanthine oxidase activity and type conversion of the enzyme which is concerned to generation of reactive oxygen species, was investigated, It was observed that xanthine oxidase activity was increased by addition of copper ion in the reaction mixture in proportional to the concentration of the metal ion until $60\;{\mu}M$, while the enzyme activity was inhibited in higher concentration of copper treatment. On the other hand, xanthine dehydrogenase activity was inhibited by copper ion addition with concentration dependently. Preincubation of enzyme source with $30\;{\mu}M$ of copper ion, which concentration marked increased the xanthine oxidase activity, unchanged the enzyme activity and type conversion compare to control in vitro system. It was also observed that copper induced xanthine oxidase activity and the enzyme type conversion was protected by dithiothreitol and penicillamine. These results indicate that the increment of the type conversion of xanthine oxidase necessarilly need the presence of copper ion in enzyme assay system.

  • PDF

Equilibrium Property of Ion Exchange Resin for Silica Removal at Ultralow Concentration (초저이온농도에서 이온교환수지에 의한 실리카제거 평형특성)

  • Yoon, Tae-Kyung;Lee, Gang-Choon;Noh, Byeong-Il
    • Journal of Environmental Science International
    • /
    • v.16 no.8
    • /
    • pp.907-912
    • /
    • 2007
  • Ion exchange resin was used to remove silica ion at ultralow concentration. The effects of temperature, type of ion exchange resin and single/mixed-resin systems on removal efficiency were estimated. As temperature increased, the slope of concentration profile became stiff, and the equilibrium concentration was higher. In the single resin system, the removal of silica was continued up to 400 min, but the silica concentration was recovered to initial concentration after 400 min due to the effect of dissolved $CO_2$. In the mixed-resin system it took about 600 min to reach equilibrium. Because of faster cation exchange reaction than anion exchange reaction, the effect of $CO_2$ could be removed. Based on the experimental results carried out in the mixed-resin system, the selectivity coefficients of silica ion for each ion exchange resin were calculated at some specific temperatures. The temperature dependency of the selectivity coefficient was expressed by the equation of Kraus-Raridon type.

Influence of Cement Type on the Diffusion Characteristics of Chloride Ion in Concrete (콘크리트의 염소이온 확산특성에 미치는 시멘트 종류의 영향)

  • Park, Jae-Im;Bae, Su-Ho;Lee, Kwang-Myong;Kim, Jee-Sang;Cha, Soo-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.573-576
    • /
    • 2006
  • To predict service life of concrete structures exposed to chloride attack, surface chloride concentration, diffusion coefficient of chloride ion, and chloride corrosion threshold value in concrete, are used as important factors. of these, as the diffusion coefficient of chloride ion for concrete is strongly influenced by concrete quality and environmental conditions of structures and may significantly change the service life of structures, it is considered as the most important factor for service life prediction. The qualitative factors affecting the penetration and diffusion of chloride ion into concrete are water-binder(W/B) ratio, age, cement type and constituents, chloride ion concentration of given environment, wet and dry conditions, etc. In this paper the influence of cement type on the diffusion characteristics of chloride ion in concrete was investigated through the chloride ion diffusion test. For this purpose, the diffusion characteristics in concrete with cement type such as ordinary portland cement(OPC), binary blended cement(BBC), and ternary blended cement(TBC) were estimated for the concrete with W/B ratios of 32% and 38%, respectively. It was observed from the test that the difussion characteristics of BBC containing OPC and ground granulated blast-furnace slag was found to be most excellent of the cement type used in this study.

  • PDF

A Study on the Ion Exchange and th Chemical Stability of Na-fluor-tetrasilicic Mica by $H^+$ions (나트륨형불소 4 규소운모의 $H^+$ 이온교환 및 화학적인 안정성에 관한 연구)

  • 송종택
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.1
    • /
    • pp.35-39
    • /
    • 1985
  • Synthetic mica $NaMg_{2.5}(Si_4O_{10})F_2 (Na-TSM)$ was treated with HCl solution and H-type exchange resin to investigate the chemical stability and the ion exchange by measuring the dissolution of chemical components and the exchanged $H^+$ ion. The replacement of $Na^+$ ion occurred in contact with HCl solution and H-type ion exchange resin at the surface of Na-TSM particles reached $Na^+$ ions at maximum value of 70~80%. $Mg^{2+}$ ion of octahedral layer became to dissolve from the pH2 solution and th amount of it dissolved in-creased almost proportional to $H^+$ ion concentration from around 0.02N $H^+$ ion equilibrium concentration. The crystalline structure of Na-TSM was destructed by dissolution of Mg2+ ion in cncentrated hydrochloric acid solution and resulted silica gel precipitation.

  • PDF

Boron Detection Technique in Silicon Thin Film Using Dynamic Time of Flight Secondary Ion Mass Spectrometry

  • Hossion, M. Abul;Arora, Brij M.
    • Mass Spectrometry Letters
    • /
    • v.12 no.1
    • /
    • pp.26-30
    • /
    • 2021
  • The impurity concentration is a crucial parameter for semiconductor thin films. Evaluating the impurity distribution in silicon thin film is another challenge. In this study, we have investigated the doping concentration of boron in silicon thin film using time of flight secondary ion mass spectrometry in dynamic mode of operation. Boron doped silicon film was grown on i) p-type silicon wafer and ii) borosilicate glass using hot wire chemical vapor deposition technique for possible applications in optoelectronic devices. Using well-tuned SIMS measurement recipe, we have detected the boron counts 101~104 along with the silicon matrix element. The secondary ion beam sputtering area, sputtering duration and mass analyser analysing duration were used as key variables for the tuning of the recipe. The quantitative analysis of counts to concentration conversion was done following standard relative sensitivity factor. The concentration of boron in silicon was determined 1017~1021 atoms/㎤. The technique will be useful for evaluating distributions of various dopants (arsenic, phosphorous, bismuth etc.) in silicon thin film efficiently.

A Study on Electric Potential Change by Pulse Voltage Polarity in Liquid (펄스전압의 극성에 따른 액중 전위변화에 관한 연구)

  • Kim Jin-Gyu;Kim Hyung-Pyo;Park Young-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.79-84
    • /
    • 2005
  • This paper proposes the new type of an ion exchange water generator system. The system has an +/- ion exchange membrane located in center and a diagonal-interdigit type electrode applied to a pulsed power. This system is studied in the liquid for the oxidation/reduction potential and the dissolved oxygen concentration by the polarity effects. Consequently, as a diagonal-interdigit type electrode is installed in each side of device, the oxidation/reduction potential and dissolved oxygen concentration by polarity changes and electrical resistivity differences be observed. An ion concentration in the ion exchange water generator system is increased by dissolved oxygen generated from oxidation/reduction potential changes.

Effect of antibacterial activity on the elution of silver ions from A-type zeolite supporting silver ions (은이온 교환 A형 제오라이트로 부터의 은이온용출이 항균력에 미치는 영향)

  • Lee, Mu Gang;Sin, Hyeon Mu;Im, Gyeong Cheon
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.89-97
    • /
    • 2004
  • An author has been known that A-type zeolite supported with silver ions has excellent antibacterial activity. However, it is no research of concern in the antibacterial activity of eluted silver ions. This study tested the elution of silver ions from A-type zeolite silver ions in deionized distilled water and NaNO$_3$ aqueous solution. In NaNO$_3$ aqueous solution of 74mM to 588mM, it was found that the concentration of silver ions and electric conductivity increased with the increasing concentration of sodium ions, and equilibrated at 15 min, and the ion exchange equilibrium coefficient, k, is 1.3${\times}$10$\^$-3/. However, deionized distilled water is not equilibrated to pass 6 months. A-type zeolite sodium ions showed no antibacterial activity. It was found that antibacterial activity was exhibited even at the concentration of 10 nM of eluted silver ions, and E-coli died with the incorporation of 2.43${\times}$10$\^$8/ Ag ion/cell. antibacterial activity of A-type zeolite silver ions were mainly attributed to hydroxyl radical.

Basic Study for Development of Denitrogenation Process by ion Exchange(II) (이온교환법에 의한 탈질소 공정개발의 기초연구(II))

  • 이민규;주창식
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.89-95
    • /
    • 1998
  • Ion exchange performance to remove nitrate in water was studied using commercially available strong base anion exchange resin of Cl- type in the batch and continuous column reactors. The performance was tested using the effluent concentration histories for continuous column or equilibrium conquilibrium between resin and solution. Anion exchange resin used in this study was more effective than activated carbon or zeolite for nitrate removal. With large resin amount or low initial concentration, nitrate removal characteristics for a typical gel-type resin was Increased. On considering the relation between the breakthrough capacity and nitrate concentration of the influent, the use of anion exchange resin were suitable for the hi선or order water treatment. The nitrate removal of above 90% could be possible until the effluent of above 650 BV was passed to the column. Thus, the commercially available strong base anion exchange resin of $Cl^-$ type used in thins study could be effectively used as economic material for treatment of the groundwater. The breakthrough curves showed the sequence of resin selectivity as $SO_4^{2-}$ > $NO_3$ > $NO^{2-}$ > $HCO_3^-$. The results of this study could be scaled up and used as a design tool for the water purification system of the real groundwater and surface water treatment processes.

  • PDF

Nitrogen Removal by Electrochemical Oxidation Using the Tube Type Electrode (튜브형 전극을 이용한 전기화학적 산화에 의한 질소제거에 관한 연구)

  • Cho, Jae-Jun;Jeong, Jong-Sik;Lee, Jae-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.580-587
    • /
    • 2004
  • The objective of this research is to investigate the electrochemical oxidation process for nitrogen removal in wastewater involving chloride ion and nitrogen compounds. The process experiment of electrochemical oxidation was conducted by using the stainless steel tube type reactor and the $Ti/IrO_2$ as anode. Free chlorine production and current efficiency variation for total nitrogen removal was compared depending on whether electrolyte is added, and the nitrogen type distribution under an operating condition. When chloride was added as electrolyte, it was found that production of free chlorine increased and the concentration of the chloride decreased as retention time passed. The concentration of chloride in influent decreased from 1,660 to 1,198 mg/L at the current density of $6.7A/dm^2$, while concentration of free chlorine increased to 132 mg/L. Current efficiency in removal of ammonium nitrogen was increased when chloride was dosed as electrolyte. It was observed that ammonium nitrogen was oxidized to nitrite and nitrate through electrochemical oxidation and that the concentration of total nitrogen in influent was reduced from 22.58 to 4.00 mg/L at the short retention time of 168 seconds through the electrochemical oxidation of nitrogen.

A new approach for predicting sulfate ion concentration in concrete

  • Mohammad Ghanooni-Bagha;Mohsen Ali Shayanfar;Sajad Momen
    • Computers and Concrete
    • /
    • v.33 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Aggressive environmental conditions, and especially the acidic effects of sulfate ion penetration, have reduced the lifetime of concrete structures in some areas, especially coastal and marine areas. In this research, at first, samples made of type II and V cement were kept in a solution of magnesium sulfate (MgSO4) for a period of 90 and 180 days, the change of appearance. Field Emission Scanning Electron Microscopy (FE-SEM) and X-Ray Diffraction (XRD), were used to analyze the microstructure and the complex mineral composition of the concrete after exposure to corrosive environments. Then solving the differential equation governing the sulfate ion penetration, which is based on the second Fick law, it has been tried to determine the concentration of sulfate ions inside the concrete. In the following, an attempt has been made to improve the prediction of sulfate ion concentration in concrete by using Crank's penetration equation. At the same time, the coefficient in the Crank's solution have been optimized by using the Particle Swarm Optimization (PSO algorithm). The comparison between the results shows that the values obtained from Crank's relation are closer to the experimental results than the equation obtained from Fick's second law and shows a more accurate prediction.