• Title/Summary/Keyword: Ion Current

Search Result 1,475, Processing Time 0.028 seconds

Effects of Freshwater Flooding on Properties of CSPE with Number of Dried-Days (건조일수에 따른 CSPE의 특성에 미치는 담수침지의 영향)

  • Kang, Myeong-Kyun;Lee, Jung-Hoon;Lee, Seung-Hoon;Jeon, Jun-Soo;Park, Young;Park, Ki-Yub;Jeong, Kyu-Won;Shin, Yong-Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.597-601
    • /
    • 2013
  • The accelerated thermal aging of a CSPE were carried out for 0, 80.82, 161.63 days at $100^{\circ}C$, which are equal to 0, 40 and 80 years of aging at $50^{\circ}C$, respectively. The volume electrical resistivities of the seawater and freshwater flooding were measured through 3-terminal circuit diagram. The volume electrical resistivities of the 0y, 40y and 80y were $2.454{\times}10^{13}{\sim}1.377{\times}10^{14}{\Omega}{\cdot}cm$, $1.121{\times}10^{13}{\sim}7.529{\times}10^{13}{\Omega}{\cdot}cm$ and $1.284{\times}10^{13}{\sim}8.974{\times}10^{13}{\Omega}{\cdot}cm$ at room temperature, respectively. The dielectric constant of the 0y, 40y and 80y were 2.922~3.431, 2.613~3.285 and 2.921~3.332 at room temperature, respectively. It is certain that the ionic ($Na^+$, $Cl^-$, $Mg^{2+}$, ${SO_4}^{2-}$, $Ca^{2+}$, $K^+$) conduction current was formed by the salinity of the seawater. The volume electrical resistivity of the cleaned CSPE via freshwater trends slightly upward with the number of dried days at room temperature. As a result, the $CH_2$ component of thermally accelerated aged CSPE decreased after seawater and freshwater flooding for 5 days respectively, whereas the atoms such as Cl, O, Pb, Al, Si, Sb, S related with the conducting ion ($Na^+$, $Cl^-$, $Mg^{2+}$, ${SO_4}^{2-}$, $Ca^{2+}$, $K^+$) component increased relatively.

Adipic Acid Assisted Sol-Gel Synthesis of Li1+x(Mn0.4Ni0.4Fe0.2)1-xO2 (0 < x < 0.3) as Cathode Materials for Lithium Ion Batteries

  • Karthikeyan, Kaliyappan;Amaresh, Samuthirapandian;Son, Ju-Nam;Kim, Shin-Ho;Kim, Min-Chul;Kim, Kwang-Jin;Lee, Sol-Nip;Lee, Yun-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.89-94
    • /
    • 2013
  • Layered $Li_{1+x}(Mn_{0.4}Ni_{0.4}Fe_{0.2})_{1-x}O_2$ (0 < x < 0.3) solid solutions were synthesized using solgel method with adipic acid as chelating agent. Structural and electrochemical properties of the prepared powders were examined by means of X-ray diffraction, Scanning electron microscopy and galvanostatic charge/discharge cycling. All powders had a phase-pure layered structure with $R\bar{3}m$ space group. The morphological studies confirmed that the size of the particles increased at higher x content. The charge-discharge profiles of the solid solution against lithium using 1 M $LiPF_6$ in EC/DMC as electrolyte revealed that the discharge capacity increases with increasing lithium content at the 3a sites. Among the cells, $Li_{1.2}(Mn_{0.32}Ni_{0.32}Fe_{0.16})O_2$ (x = 0.2)/$Li^+$ exhibits a good electrochemical property with maximum initial capacity of 160 $mAhg^{-1}$ between 2-4.5 V at 0.1 $mAcm^{-2}$ current density and the capacity retention after 25 cycles was 92%. Whereas, the cell fabricated with x = 0.3 sample showed continuous capacity fading due to the formation of spinel like structure during the subsequent cycling. The preparation of solid solutions based on $LiNiO_2-LiFeO_2-Li_2MnO_3$ has improved the properties of its end members.

Preparation of High Spin Five-Coordinate Iron(II) Complexes of 1,4,8,11-Tetraazacyclotetradecane and High Spin Six-Coordinate Iron(II) Complexes of 1,5,8,12-Tetraazadodecane (1,4,8,11-테트라아자사이클로테트라데칸의 높은 스핀 다섯배위철(II) 착화합물과 1,5,8,12-테트라아자도데칸의 높은 스핀 여섯배위철(II) 착화합물의 합성)

  • Myunghyun Paik Suh
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.2
    • /
    • pp.139-145
    • /
    • 1980
  • High spin iron(II) complexes of 1,4,8,11-tetraazacyclotetradecane (cyclam), a macrocyclic ligand, and 1,5,8,12-tetraazadodecane (3,2,3-tet), a noncyclic ligand, have been prepared. The reaction of low spin $[Fe(cyclam)(CH_3CN)_2](ClO_4)_2$ with chloride ion in methanol produces high-spin $[Fe(cyclam)Cl]ClO_4$. Although $[Fe(cyclam)(CH_3CN)_2](ClO_4)_2$ is low spin, $[Fe(3,2,3-tet)(CH_3CN)_2](ClO_4)_2$ isolated in the present study is high spin. This difference is explained in terms of the smaller constrictive effect exerted by the noncyclic ligand than the cyclic ligand. The isolation of $[Fe(cyclam)Cl]ClO_4$ provides evidences against the current view that the presence of either unsaturation or substituents on the macrocyclic ligands is necessary for the successful preparation of high spin five-coordinate iron (II) complexes. Reactions of $[Fe(cyclam)Cl]ClO_4\;and\;[Fe(3,2,3-tet)(CH_3CN)_2](ClO_4)_2$ with carbon monoxide yield low spin six-coordinate $[Fe(cyclam)Cl(CO)]ClO_4\;and\;[Fe(3.2,3-tet)(CH_3CN)(CO)](ClO_4)_2$, respectively.

  • PDF

A Study on the Effect of Gamma Background in Low Power Startup Physics Tests (저출력 노물리 시험에서의 감마 Background의 영향에 관한 연구)

  • Bae, Chang-Joon;Lee, Ki-Bog
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.361-370
    • /
    • 1993
  • Low power physics tests should be peformed for the domestic pressurized light water reactors (PWRs) after refueling. The tests are peformed to ensure that operating characteristics of the core are consistent with predictions and that the core can be operated as designed. But in some low power physics tests, slow but steady reactivity increasing phenomena were noticed after step reactivity insertion by the control rod movement. These reactivity increasing phenomena are due to the low flux level and the gamma background because an uncompensated ion chamber (UIC) is used as the ex-core neutron detector. The gamma background may affect the results or the lour power physics tests. The aims or this paper are to analyze the grounds of such phenomena, to simulate a reference bank worth measurement test and to present a resolution quantitatively. In this study, the gamma background level was estimated by numerically solving the point kinetics equations accounting the gamma background effect. The reactivity computer check test was simulated to verify the model. Also, an appropriate neutron flux level was determined by simulating the reference bank worth measurement test. The determined neutron flux level is approximately 0.3 of the nuclear heating flux. This level is about 3 times as high as the current test upper limit specified in the test procedure. Then, the findings from this work were successfully applied to Kori unit 4 cycle 7 and Yonggwang unit 1 cycle 7 physics tests.

  • PDF

Electrochemical Behavior of Dissolved Hydrogen and Hydrogen Peroxide in Boric Acid Solution at the Elevated Temperature (붕산수용액 매질에서 용존수소와 과산화수소의 고온 전기화학 거동연구)

  • Yeon Jei-Won;Woo Seung-Kyun;Choi Young-Ku;Jung Yongju;Kim Won-Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.1
    • /
    • pp.21-25
    • /
    • 2004
  • The electrochemical behaviors of dissolved hydrogen and hydrogen peroxide at a platinum disk electrode were investigated in boric acid solution by potentiostatic polarization method at the temperature of 25 and $200^{\circ}C$. The oxidation of dissolved hydrogen at $25^{\circ}C$ was kinetically controlled reaction, the rate of which depends upon the electron transfer on the electrode surface. As temperature was raised, however, the electrochemical characteristics of dissolved hydrogen were changed from a kinetically controlled reaction to a diffusion controlled one. One notable feature, with dissolved hydrogen at high temperature, is that an abnormal potential range was observed, where the oxidation rate of dissolved hydrogen rapidly decreased just before starting potential of water oxidation. We think it is caused by the deactivation of the electrode that results from the adsorption of hydroxyl ion on the surface of the platinum disk. On the contrary, a definite change with temperature was not identified in the case of the hydrogen peroxide except for the increase in current density that was due to the increasing diffusion coefcient with an increase of temperature.

A Study on Rehabilitation Treatment Using Radiofrequency Treatment (고주파 통증치료기를 이용한 재활 치료에 대한 연구)

  • Jo, Jae-Hyun;Lee, Sang-Yong;Lee, Geun-Yong;Yoon, Se-Jin;Cheong, Ha-Young;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.212-218
    • /
    • 2020
  • When Radiofrequency energy is applied to the human body, the vibration width is very short. Therefore, the electrolyte burn generated when using the direct current does not occur. Ion molecules, polarized molecules, etc., vibrate more than 40,000 times per second, converting them into frictional heat to generate deep heat. The blood flow of capillaries increases 4-5 times more than at rest, increasing the supply of oxygen, nutrients, antibodies, and white blood cells. In addition, the electrochemical reaction does not occur because the vibration width and the pulsation period are very short. It is a physical factor treatment method that does not stimulate the sensory nerves and motor nerves. In this study, an isotonic exercise is performed in a young normal adult using a Radiofrequency pain treatment device. The purpose of this study is to integrate rehabilitation therapy by measuring electromyography data during isotonic exercise and confirming the effect on changes in motor neuron response. The EMG data generated when isotonic exercise of the forearm biceps muscle and the EMG data measured after the use of a Radiofrequency pain treatment device after exercise were RMS, respectively, and verified through t-test. It was confirmed that there was a significant difference in both men and women because the t-value was smaller than the significance level p (<.05).

A Study on the Durability Improvement of Highway-Subsidiary Concrete Structure Exposed to Deicing Salt and Freeze-Thaw (동결융해 및 제설제에 노출된 고속도로 소구조물 콘크리트의 내구성 개선 연구)

  • Lee, Byung-Duk;Choi, Yoon-Suk;Kim, Young-Geun;Choi, Jae-Seok;Kim, Il-Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.128-135
    • /
    • 2016
  • In the current concrete structure of the highway is still the major problem most of concrete deterioration caused by the freeze-thaw and deicing salt, which is of issues that are not completely resolved. In particular, a single freezing event does not cause much harm, durability of concrete under multi-deterioration environment by repeated freeze-thaw and deicing salt is rapidly degraded and reduce its service life. In this study, the exposure environmental condition according the regional highway points were established. The damage condition and chloride content of the concrete at general and severe environmental exposure condition were also investigated. In addition, the experimental test of chloride ion permeability, scaling resistant and freeze-thaw resistance were carried out to improve the durability of the mechanical placing concrete of subsidiary structure. According to the results of this study, in observation of concrete surface condition, the concrete exposed by severe environmental condition showed broad ranges of damage with high chloride contents. Meanwhile, the water-binder(W/B) ratio and the less water content, and fly ash concrete than the specified existing mix proportion is significantly improved the durability. Also, the optimal mix proportion derived for test is satisfied the strength and air contents, water-binder ratio, and durability criteria of concrete specifications, as well as service life seems greatly improved.

Flow Cytometric Analysis of Endothelial Cell Viability in Arterial Allograft (동종동맥판 혈관내피세포의 생육성 평가에 관한 연구)

  • 임창영;홍은경
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.553-558
    • /
    • 1997
  • Arterial allografts have known advantages over prosthetic vascular conduit for treatment of heart valvular disease, congenital heart disease and aortic disease. Cell viability may play a role in determining the longterm outcome of allografts. Endothelial cell is one important part in determining the allograft viability. To evaluate the viability of endothelial cells using current allograft preservation technique, porcine heart valve leaflets and arterial wall were subjected to collagenase digestion. Single endothelial cell suspension was labeled with GSA-PITC(Griffonia simplicifolia agglutininfluorescein isothiocyan te), a vascular, endothelial cell specific marker. The cell suspension was washed and incubated with Pl(Propidium iodide), which does not bind with viable cells, Endothelial cell viability was evaluated by calculating the percentage of GSA-FITC(+) and Pl(-) group using flowcytometric analysis. Allografts were treated with $4^{\circ}C$ antibiotic solo!ion for 24 hours for sterilization. After this, half of allografts were stored in $4^{\circ}C$ RPMI 1640 with HEPES buffer culture medium with 10% fetal bovine serum for 1 to 14 days(Group I). Another half of allografts were cryopreserved with a currently used technique (Group II). During the procurement and sterilization of arterial allografts, 22.8% and 24.4% of endothelial cell viability declined, respectively. In Group I, 11.9% of endothelial cell viability declined further steadily during 14 days of storage. In Group II, 13.7% of endothelial cell viability declined. These results show that largest loss of endothelial cell viability occurs during the nitial process. After 14 days of arterial allograft storage under $4^{\circ}C$ nutrient medium or cryopreservation, about 40% of endothelial cell viability is maintained. There were no differences between the endothelial cell viability from aortic valve leaflet, pulmonic valve leaflets, aortic wall and pulmonic wall.

  • PDF

Thickness Determination of Ultrathin Gate Oxide Grown by Wet Oxidation

  • 장효식;황현상;이확주;조현모;김현경;문대원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.107-107
    • /
    • 2000
  • 최근 반도체 소자의 고집적화 및 대용량화의 경향에 다라 MOSFET 소자 제작에 이동되는 게이트 산화막의 두께가 수 nm 정도까지 점점 얇아지는 추세이고 Giga-DRAM급 차세대 UNSI소자를 제작하기 위해 5nm이하의 게이트 절연막이 요구된다. 이런 절연막의 두께감소는 게이트 정전용량을 증가시켜 트랜지스터의 속도를 빠르게 하며, 동시에 저전압동작을 가능하게 하기 때문에 게이트 산화막의 두께는 MOS공정세대가 진행되어감에 따라 계속 감소할 것이다. 따라서 절연막 두께는 소자의 동작 특성을 결정하는 중요한 요소이므로 이에 대한 정확한 평가 방법의 확보는 공정 control 측면에서 필수적이다. 그러나, 절연막의 두께가 작아지면서 게이트 산화막과 crystalline siliconrksm이 계면효과가 박막의 두께에 심각한 영향을 주기 때문에 정확한 두께 계측이 어렵고 계측방법에 따라서 두께 계측의 차이가 난다. 따라서 차세대 반도체 소자의 개발 및 양산 체계를 확립하기 위해서는 산화막의 두께가 10nm보다 작은 1nm-5nm 수준의 박막 시료에 대한 두께 계측 방법이 확립이 되어야 한다. 따라서, 본 연구에서는 습식 산화 공정으로 제작된 3nm-7nm 의 게이트 절연막을 현재까지 알려진 다양한 두께 평가방법을 비교 연구하였다. 절연막을 MEIS (Medim Energy Ion Scattering), 0.015nm의 고감도를 가지는 SE (Spectroscopic Ellipsometry), XPS, 고분해능 전자현미경 (TEM)을 이용하여 측정 비교하였다. 또한 polysilicon gate를 가지는 MOS capacitor를 제작하여 소자의 Capacitance-Voltage 및 Current-Voltage를 측정하여 절연막 두께를 계산하여 가장 좋은 두께 계측 방법을 찾고자 한다.다. 마이크로스트립 링 공진기는 링의 원주길이가 전자기파 파장길이의 정수배가 되면 공진이 일어나는 구조이다. Fused quartz를 기판으로 하여 증착압력을 변수로 하여 TiO2 박막을 증착하였다. 그리고 그 위에 은 (silver)을 사용하여 링 패턴을 형성하였다. 이와 같이 공진기를 제작하여 network analyzer (HP 8510C)로 마이크로파 대역에서의 공진특서을 측정하였다. 공진특성으로부터 전체 품질계수와 유효유전율, 그리고 TiO2 박막의 품질계수를 얻어내었다. 측정결과 rutile에서 anatase로 박막의 상이 변할수록 유전율은 감소하고 유전손실은 증가하는 결과를 나타내었다.의 성장률이 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 줄어들어 성장률이 Silane가스량에 의해 지배됨을 볼 수 있다. UV-VIS spectrophotometer에 의한 비정질 SiC 박막의 투과도와 파장과의 관계에 있어 유리를 기판으로 사용했으므로 유리의투과도를 감안했으며, 유리에 대한 상대적인 비율 관계로 투과도를 나타냈었다. 또한 비저질 SiC 박막의 흡수계수는 Ellipsometry에 의해 측정된 Δ과 Ψ값을 이용하여 시뮬레이션한 결과로 비정질 SiC 박막의 두께를 이용하여 구하였다. 또한 Tauc Plot을 통해 박막의 optical band gap을 2.6~3.7eV로 조절할 수 있었다. 20$0^{\circ}C$이상으로 증가시켜도 광투과율은 큰 변화를 나타내지 않았다.부터 전분-지질복합제의 형성 촉진이 시사되었다.이것으로 인하여 호화억제에 의한 노화 방지효과가 기대되었지만 실제로 빵의 노화는 현저히 진행되었다

  • PDF

A Classical Molecular Dynamics Study of the Mg2+ Coordination in Todorokite (토도로카이트 내 Mg2+ 배위구조에 대한 고전분자동력학 연구)

  • Kim, Juhyeok;Lee, Jin-Yong;Kwon, Kideok D.
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.151-162
    • /
    • 2019
  • Todorokite, a tunnel-structured manganese oxide, can contain cations within the relatively large nanopores created by the $3{\times}3$ Mn octahedra. Because todorokite is poorly crystalline and found as aggregates mixed with other phases of Mn oxides in nature, the coordination structure of cations in the nanopores is challenging to fully characterize in experiment. In the current article, we report the atomistic coordination structures of $Mg^{2+}$ ions in todorokite tunnel nanopores using the classical molecular dynamics (MD) simulations. In experiment, $Mg^{2+}$ is known to occupy the center of the nanopores. In our MD simulations, 60 % of $Mg^{2+}$ ions were located at the center of the nanopores; 40 % of the ions were found at the corners. All $Mg^{2+}$ located at the center formed the six-fold coordination with water molecules, just as the ion in bulk aqueous solution. $Mg^{2+}$ ions at the corners also formed the six-fold coordination with not only water molecules but also Mn octahedral surface oxygens. The mean squared displacements were calculated to examine the dynamic features of $Mg^{2+}$ ions in the one-dimensional (1D) nanopores. Our MD simulations indicate that the dynamic features of water molecules and the cations observed in bulk aqueous solution are lost in the 1D nanopores of todorokite.