• 제목/요약/키워드: Inverted V (chevron) braced steel frames

검색결과 3건 처리시간 0.015초

역V형 철골 중심가새골조의 정적/동적 지퍼기둥.설계법 (Staticand Dynamic Design of Zipper Columns in Inverted V Braced Steel Frames)

  • 이철호;김정재
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.733-740
    • /
    • 2006
  • Inverted V (or chevron) braced steel frames have been seen as being highly prone to soft story response once the compression brace buckles under earthquake loading. To salvage chevron braced frames. the concept of the zipper column was proposed many years ago such that the zipper column can redistribute the inelastic demand over the height of the building. However. rational design method for the zipper column has not been established yet. In this paper, a new dynamic design method for the zipper column was proposed by combining the refined physical braced model and modal pushover analysis. Inelastic dynamic analysis conducted on 6 story building model showed that the proposed method was more superior to the existing static design method and was very effective in improving seismic performance of chevron braced steel frames.

  • PDF

역V형 철골 가새골조의 비탄성거동 및 내진성능향상 방안에 관한 연구 (Inelastic Behavior and Seismic Retrofit of Inverted V Braced Steel Frames)

  • 김남훈;이철호
    • 한국강구조학회 논문집
    • /
    • 제15권5호통권66호
    • /
    • pp.571-578
    • /
    • 2003
  • 본 논문에서는 중심가새골조 가운데 가정 널리 사용되는 역V형 철골 가새골조의 내진거동을 탄소성 후좌굴해석에 의해 고찰하고, 압축가새의 좌굴이 최초로 발생한 층에 소성화가 집중되는 약층화 현상을 완화할 수 있는 효과적 내진보강 방안을 제시하고자 하였다. 즉 좌굴이 발생한 층에 집중되는 비탄성변형을 건물전체로 재분재하는 기능을 갖는 인장재(tie bar)를 삽입하여 내진성능을 효과적으로 개선할 수 있음을 입증하였다. 아울러 압축가새의 좌굴발생 순서를 감안하여 보강 인장재를 경제적으로 설계할 수 있는 실용적 설계방안을 제시하였다.

Seismic design rules for ductile Eurocode-compliant two-storey X concentrically braced frames

  • Costanzo, Silvia;D'Aniello, Mario;Landolfo, Raffaele
    • Steel and Composite Structures
    • /
    • 제36권3호
    • /
    • pp.273-291
    • /
    • 2020
  • Two-storey X-bracings are currently very popular in European practice, as respect to chevron and simple X bracings, owing to the advantages of reducing the bending demand in the brace-intercepted beams in V and inverted-V configurations and optimizing the design of gusset plate connections. However, rules for two-storey X braced frames are not clearly specified within current version of EN1998-1, thus leading to different interpretations of the code by designers. The research presented in this paper is addressed at investigating the seismic behaviour of two-storey X concentrically braced frames in order to revise the design rules within EN1998-1. Therefore, five different design criteria are discussed, and their effectiveness is investigated. With this aim, a comprehensive numerical parametric study is carried out considering a set of planar frames extracted from a set of structural archetypes that are representative of regular low, medium and high-rise buildings. The obtained results show that the proposed design criteria ensure satisfactory seismic performance.