• Title/Summary/Keyword: Intravascular ultrasonography

Search Result 6, Processing Time 0.017 seconds

Development of a Method for Measuring Image Quality of Intra Vascular Ultrasound Images using Image Analysis Program (영상 분석 프로그램을 이용한 혈관 내 초음파 영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Han, Jae-Bok;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.621-628
    • /
    • 2021
  • Prior studies on frequency-related image quality analysis of intravascular ultrasound catheters are lacking both in Korea and abroad. Therefore, this study was conducted to prepare a standard for measuring the image quality using the program and to suggest a measuring method to researchers related to the quality analysis of intravascular ultrasound images. For the target, the vessel lumen size is 3.0 - 4.0 mm. Before using intravascular ultrasound, thoroughly clean the ultrasound catheter so that no air or foreign substances enter it. Normal vascular images and lesion vascular images of sufficiently dilated images were used. As a standard image acquisition method, the image of the end-systolic section, which has the best evaluation of vascular lesions when using intravascular ultrasound, was acquired retrospectively through the DCAS PACS program to set the standard. When setting the measurement method criteria, we proposed a standard setting method that corresponds to the concentric and eccentric circles of normal and lesion vessels. By applying this criterion, we proposed a method for measuring the lumen and lateral cavities of normal and lesion vessels of interest and background area. In conclusion, if the image quality of intravascular ultrasonography is measured through the method devised by these researchers, consistent quality measurement is possible regardless of the type of intravascular ultrasound catheter. Therefore, it is thought that it can be applied as a guideline for the actual image quality measurement method in the study related to intravascular ultrasound image quality.

A Case of Hypernatremic Dehydration in an Exclusively Breast-Fed Newborn Infant (모유수유 신생아에게 발생한 고나트륨혈성 탈수증 1례)

  • Park, Kyung Pil;Kim, Jin Kyung;Kim, Heng Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.6
    • /
    • pp.790-795
    • /
    • 2002
  • Sporadic reports of hypernatremic dehydration in breastfed newborn infants have appeared in medical literature for at least 3 decades. We report the first case of hypernatremic dehydration resulting from inadequate breast-feeding in Korea. A 14-day old baby, born to a mentally retarded mother, was transferred to our hospital with a body weight loss of 460 g since birth(17%) and a serum sodium(Na) level of 179 mEq/L, after initial hydration at another hospital. On admission, a cardiac murmur was heard and an enlarged liver was palpated. Cardiac ultrasonogram revealed ventricular septal defect and ostium secundum atrial septal defect. During hydration, a seizure-like attack developed. Serum Na decreased to 135 mEq/L on the 5th day of admission. Brain ultrasonography and brain magnetic resonance image revealed no remarkable abnormalities. Electroencephalography was normal. She suffered from prerenal azotemia, hyperglycemia and disseminated intravascular coagulation at admission but was treated successfully. Heart failure was also controlled with dobutamine, diuretics and digoxin.

In Vivo Enhanced Indocyanine Green-Photothermal Therapy for a Subconjunctival Tumor

  • Kim, Chang Zoo;Lee, Sang Joon;Hwang, Sang Seok;Chae, Yu-Gyeong;Kwon, Daa Young;Ko, Taek Yong;Kim, Jun Hyeong;Jung, Min Jung;Masanganise, Rangarirai;Oak, Chulho;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.311-321
    • /
    • 2021
  • Indocyanine green (ICG) is a dye approved for use in clinical diagnostics. ICG remains in the intravascular space following intravenous administration, due to its ability to rapidly bind to the plasma proteins, and its therapeutic potential has been studied in well-vascularized cutaneous tumors. Here we have evaluated the clinical response of a subconjunctival tumor to photothermal therapy (PTT) using an ICG-enhanced near-infrared diode laser and its adverse effects, in a rabbit. 22 male New Zealand white rabbits with subconjunctival tumors were enrolled (control group 6, laser-only group 8, laser-with-ICG group 8). Rabbits in the laser-with-ICG group received ICG (twice, 2 mg/kg each time, intravenously) directly followed by irradiation with a diode laser (λ = 810 nm). Rabbits in the laser-only group were irradiated with the diode laser. ICG angiography, ultrasonography, and pathologic examination were performed to evaluate PTT response at specific time points (0, 2, and 4 weeks after PTT). Two weeks after initial treatment, the eight rabbits treated by laser with ICG showed a 100% response rate. There was no clinical response in both laser-only and control groups. ICG-PTT is a potential and effective palliative therapeutic modality for subconjunctival tumors.

Discordance Between Angiographic Assessment and Fractional Flow Reserve or Intravascular Ultrasound in Intermediate Coronary Lesions: A Post-hoc Analysis of the FLAVOUR Trial

  • Jung-Hee Lee;Sung Gyun Ahn;Ho Sung Jeon;Jun-Won Lee;Young Jin Youn;Jinlong Zhang;Xinyang Hu;Jian'an Wang;Joo Myung Lee;Joo-Yong Hahn;Chang-Wook Nam;Joon-Hyung Doh;Bong-Ki Lee;Weon Kim;Jinyu Huang;Fan Jiang;Hao Zhou;Peng Chen;Lijiang Tang;Wenbing Jiang;Xiaomin Chen;Wenming He;Myeong-Ho Yoon;Seung-Jea Tahk;Ung Kim;You-Jeong Ki;Eun-Seok Shin;Doyeon Hwang;Jeehoon Kang;Hyo-Soo Kim;Bon-Kwon Koo
    • Korean Circulation Journal
    • /
    • v.54 no.8
    • /
    • pp.485-496
    • /
    • 2024
  • Background and Objectives: Angiographic assessment of coronary stenosis severity using quantitative coronary angiography (QCA) is often inconsistent with that based on fractional flow reserve (FFR) or intravascular ultrasound (IVUS). We investigated the incidence of discrepancies between QCA and FFR or IVUS, and the outcomes of FFR- and IVUS-guided strategies in discordant coronary lesions. Methods: This study was a post-hoc analysis of the FLAVOUR study. We used a QCA-derived diameter stenosis (DS) of 60% or greater, the highest tertile, to classify coronary lesions as concordant or discordant with FFR or IVUS criteria for percutaneous coronary intervention (PCI). The patient-oriented composite outcome (POCO) was defined as a composite of death, myocardial infarction, or revascularization at 24 months. Results: The discordance rate between QCA and FFR or IVUS was 30.2% (n=551). The QCA-FFR discordance rate was numerically lower than the QCA-IVUS discordance rate (28.2% vs. 32.4%, p=0.050). In 200 patients with ≥60% DS, PCI was deferred according to negative FFR (n=141) and negative IVUS (n=59) (15.3% vs. 6.5%, p<0.001). The POCO incidence was comparable between the FFR- and IVUS-guided deferral strategies (5.9% vs. 3.4%, p=0.479). Conversely, 351 patients with DS <60% underwent PCI according to positive FFR (n=118) and positive IVUS (n=233) (12.8% vs. 25.9%, p<0.001). FFR- and IVUS-guided PCI did not differ in the incidence of POCO (9.5% vs. 6.5%, p=0.294). Conclusions: The proportion of QCA-FFR or IVUS discordance was approximately one third for intermediate coronary lesions. FFR- or IVUS-guided strategies for these lesions were comparable with respect to POCO at 24 months.

Portal Vein Thrombosis in a Dog with Dirofilariasis (심장사상충에 감염된 개에서 발생한 문정맥혈전증)

  • Yun, Seok-Ju;Cheon, Haeng-Bok;Han, Jae-Ik;Kang, Ji-Houn;Chang, Jin-Hwa;Na, Ki-Jeong;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.600-604
    • /
    • 2010
  • A ten-year-old female mongrel dog was presented to Veterinary Medical Center, Chungbuk National University with the signs of anorexia, weakness, and hemoglobinuria. Patient had been diagnosed as dirofilariasis based on heartworm antigen test and treated with adulticide (melarsomine) at local hospital one day before admission. On laboratory examinations, there were hypochromic and microcytic regenerative anemia, thrombocytopenia, moderate neutrophilia, and increase ALT, AST, and ALP. Radiographic exam showed main pulmonary artery bulging, pulmonary infiltration and hypervascularity, reduced abdominal serosal detail and mild hepatomegaly. Abdominal ultrasonographic exam showed mild peritoneal effusion and large hyperechoic thrombi at trifurcation of the porta hepatica and the splenic vein. In addition, intraluminal low density area and intravascular filling defect were confirmed on contrast enhanced CT scanning at the same anatomic locations. Patient was treated with anticoagulant and thrombolytic therapy. On day 42 after treatment, complete resolution of thrombi was confirmed via ultrasonography and improvement of clinical signs was observed.

Coronary Artery Lumen Segmentation Using Location-Adaptive Threshold in Coronary Computed Tomographic Angiography: A Proof-of-Concept

  • Cheong-Il Shin;Sang Joon Park;Ji-Hyun Kim;Yeonyee Elizabeth Yoon;Eun-Ah Park;Bon-Kwon Koo;Whal Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.688-698
    • /
    • 2021
  • Objective: To compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS). Materials and Methods: The Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods. Bland-Altman plots were used to evaluate the agreement between the measurements. Results: Lumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 mm3; 95% confidence interval [CI], 4.9-24.3 mm3); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, -0.7 mm3; 95% CI, -9.1-7.7 mm3). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 mm2; 95% CI, 0.89-1.25 mm2) but not in the larger lumen area group (mean of difference, -0.07 mm2; 95% CI, -0.22-0.08 mm2). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 mm2; 95% CI, 0.27-0.65 mm2) than in that of IVUS and SATM (1.53 mm2; 95% CI, 1.27-1.79 mm2). Conclusion: SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.