• Title/Summary/Keyword: Intraoperative Complications

Search Result 275, Processing Time 0.027 seconds

Robot-Assisted Repair of Atrial Septal Defect: A Comparison of Beating and Non-Beating Heart Surgery

  • Yun, Taeyoung;Kim, Hakju;Sohn, Bongyeon;Chang, Hyoung Woo;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.55-60
    • /
    • 2022
  • Background: Robot-assisted repair of atrial septal defect (ASD) can be performed under either beating-heart or non-beating-heart conditions. However, the risk of cerebral air embolism (i.e., stroke) is a concern in the beating-heart approach. This study aimed to compare the outcomes of beating- and non-beating-heart approaches in robot-assisted ASD repair. Methods: From 2010 to 2019, a total of 45 patients (mean age, 43.4±14.6 years; range, 19-79 years) underwent ASD repair using the da Vinci robotic surgical system. Twenty-seven of these cases were performed on a beating heart (beating-heart group, n=27) and the other cases were performed on an arrested or fibrillating heart (non-beating-heart group, n=18). Cardiopulmonary bypass (CPB) was achieved via cannulation of the femoral vessels and the right internal jugular vein in all patients. Results: Complete ASD closure was verified using intraoperative transesophageal echocardiography in all patients. Conversion to open surgery was not performed in any cases, and there were no major complications. All patients recovered from anesthesia without any immediate postoperative neurologic symptoms. In a subgroup analysis of isolated ASD patch repair (beating-heart group: n=22 vs. non-beating-heart group: n=5), the operation time and CPB time were shorter in the beating-heart group (234±38 vs. 253±29 minutes, p=0.133 and 113±28 vs. 143±29 minutes, p=0.034, respectively). Conclusion: Robot-assisted ASD repair can be safely performed with the beating-heart approach. No additional risk in terms of cerebral embolism was found in the beating-heart group.

Comparative Study of Surgical Treatment for Concomitant Ankle Joint Injury in Tibia Shaft Fracture (경골 간부 골절에서 족관절 손상에 대한 수술적 치료의 비교 연구)

  • Jinho Park;Seungjin Lee;Hyobeom Lee;Gab-Lae Kim;Jiwoo Chang;Heebum Hahm
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.3
    • /
    • pp.87-92
    • /
    • 2023
  • Purpose: Concomitant ankle injuries associated with tibial shaft fractures can affect postoperative ankle joint pain and various postoperative ankle complications. This study compared the clinical outcomes between surgical treatment and conservative treatment of concomitant ankle injuries associated with tibial shaft fractures. Materials and Methods: From January 2015 to June 2020, a retrospective study was conducted on 118 tibia shaft fractures at the orthopedics department of the hospital. Associated ankle injuries were analyzed using plain radiographs, computed tomography (CT), magnetic resonance imaging (MRI), and intraoperative stress exams. The clinical outcomes were compared using the pain visual analog scale (pain VAS), American Orthopaedic Foot and Ankle Society Ankle-Hindfoot score (AOFAS score), and Karlsson-Peterson ankle score (KP score). Results: Seventy-two (61.02%) of the 118 cases were diagnosed with associated ankle injuries. Fifty-six cases underwent surgery for the ankle injury, and 16 cases underwent conservative treatment. The clinical results (according to the pain VAS score, AOFAS score, the KP score) were 1.79±1.26, 94.48±4.03, and 94.57±3.60, respectively, in the surgical treatment group, and 3.00±1.03, 91.06±3.02, and 91.25±3.31, respectively, in the conservative treatment group. Conclusion: Surgical treatment showed better clinical outcomes than conservative treatment in concomitant ankle injury in tibia fractures. Therefore, surgical treatment produces better clinical outcomes than conservative treatment in concomitant ankle injuries in tibia fractures. Hence to improve the clinical outcomes, more attention is needed on ankle joint injury in tibial shaft fractures for selecting suitable surgical treatments for those patients.

Is central pancreatectomy an effective alternative to distal pancreatectomy for low-grade pancreatic neck and body tumors: A 20-year single-center propensity score-matched case-control study

  • Ashish Kumar Bansal;Bheerappa Nagari;Phani Kumar Nekarakanti;Amith Kumar Pakkala;Venu Madhav Thumma;Surya Ramachandra Varma Gunturi;Madhur Pardasani
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.1
    • /
    • pp.87-94
    • /
    • 2023
  • Backgrounds/Aims: Central pancreatectomy (CP) is associated with a higher rate of postoperative pancreatic fistula (POPF), and it is less preferred over distal pancreatectomy (DP). We compared the short- and long-term outcomes between CP and DP for low-grade pancreatic neck and body tumors. Methods: This was a propensity score-matched case-control study of patients who underwent either CP or DP for low-grade pancreatic neck and body tumors from 2003 to 2020 in a tertiary care unit in southern India. Patients with a tumor >10 cm or a distal residual stump length of <4 cm were excluded. Demographics, clinical profile, intraoperative and postoperative parameters, and the long-term postoperative outcomes for exocrine and endocrine insufficiency, weight gain, and the 36-Item Short Form Survey (SF-36) quality of life questionnaire were compared. Results: Eighty-eight patients (CP: n=37 [cases], DP: n=51 [control]) were included in the unmatched group after excluding 21 patients (meeting exclusion criteria). After matching, both groups had 37 patients. The clinical and demographic profiles were comparable between the two groups. Blood loss and POPF rates were significantly higher in the CP group. However, Clavien-Dindo grades of complications were similar between the two groups (p = 0.27). At a median follow-up of 38 months (range = 187 months), exocrine sufficiency was similar between the two groups. Endocrine sufficiency, weight gain, SF-36 pain control score, and general health score were significantly better in the CP group. Conclusions: Despite equivalent clinically significant morbidities, long-term outcomes are better after CP compared to DP in low-grade pancreatic body tumors.

Complication of Intraoperative Radiation Therapy (IORT) in Gastric Cancer (위암의 수술중 방사선 치료의 합병증)

  • Kim Myung Se;Kim Sung Kyu;Song Sung Kyo;Kim Hong Jin;Kwan Koing Bo;Kim Heung Dae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.187-192
    • /
    • 1992
  • Local control is the important prognostic factor in cancer treatment because local control decrease the relative risk of metastatic spread and inclose distant metastasis free suwival. IORT is the modality which could increase local control without incressing complication, combined with curative operation. Eventhough we could achieve significant deacreased local failure by IORT and curative resection, it should not be committed as a main treatment modality without proving acceptable complications. Therapeutic Radiology Department of Yeungnam University Medical Center have tried 58 IORT from June 15, 1988, and performed 53 IORT En patients with gastric cancer. No local failure has been reported by regular follow up so far. Nine cases ($17\%$) of treatment related complicaiton were reported including intestinal obstrution, hemorrhage, sepsis, and bone marrow depression. These complications could be comparable to Jo's $25.2\%$ (chemotherapy + operation), Kim's $18\%$ (chemotherapy only in inoperable patients), because our treatment regimen is consisted of IORT (1500 cGy), external irradiation (--4500 cGy) and extensive chemotherapy(FAM, 5FU + MMC, BACOP).

  • PDF

Epicardial Repair of Acute Atrioventricular Groove Disruption Complicating Mitral Valve Replacement - A case report - (승모판막치환술 후 발생한 급성 제1형 좌심실 파열에 대한 심외막적 봉합 - 1예 보고 -)

  • Cho, Kwang-Ree;Kang, Jae-Geul;Jin, Sung-Hoon
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.855-858
    • /
    • 2007
  • A left ventricular rupture might be one of the most disastrous complications after a mitral valve replacement. An acute atrioventricular groove rupture (type I) was detected in a 54-year-old female diagnosed with a mitral stenosis combined with severe tricuspid regurgitation. She had a prior medical history of an open mitral commissurotomy in Japan at 30 years ago. The surgical findings suggested that the previous procedure was not a simple commissurotomy but a commissurotomy combined with a posteromedial annuloplasty procedure. After a successful mitral valve replacement and a measured (De Vega type) tricuspid annuloplasty, the weaning from a cardiopulmonary bypass was uneventful. However, copious intraoperative bleeding from the posterior wall was detected and the cardiopulmonary bypass was restarted. Exposure of the posterior wall of the left ventricle showed bleeding from the atrioventricular groove 3 cm lateral to the left atrial auricle. Under the impression of a Type I left ventricular rupture, epicardial repair (primary repair of the Teflon felt pledgetted suture, continuous sealing suture using auto-pericardial patch and application of fibrin-sealant) was attempted. Successful local control was made and the patient recovered uneventfully. The patient was discharged at 14 postoperative days without complications. We report this successful epicardial repair of an acute type I left ventricular rupture after mitral valve replacement.

The utility of three-dimensional models in complex microsurgical reconstruction

  • Ogunleye, Adeyemi A.;Deptula, Peter L.;Inchauste, Suzie M.;Zelones, Justin T.;Walters, Shannon;Gifford, Kyle;LeCastillo, Chris;Napel, Sandy;Fleischmann, Dominik;Nguyen, Dung H.
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.428-434
    • /
    • 2020
  • Background Three-dimensional (3D) model printing improves visualization of anatomical structures in space compared to two-dimensional (2D) data and creates an exact model of the surgical site that can be used for reference during surgery. There is limited evidence on the effects of using 3D models in microsurgical reconstruction on improving clinical outcomes. Methods A retrospective review of patients undergoing reconstructive breast microsurgery procedures from 2017 to 2019 who received computed tomography angiography (CTA) scans only or with 3D models for preoperative surgical planning were performed. Preoperative decision-making to undergo a deep inferior epigastric perforator (DIEP) versus muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flap, as well as whether the decision changed during flap harvest and postoperative complications were tracked based on the preoperative imaging used. In addition, we describe three example cases showing direct application of 3D mold as an accurate model to guide intraoperative dissection in complex microsurgical reconstruction. Results Fifty-eight abdominal-based breast free-flaps performed using conventional CTA were compared with a matched cohort of 58 breast free-flaps performed with 3D model print. There was no flap loss in either group. There was a significant reduction in flap harvest time with use of 3D model (CTA vs. 3D, 117.7±14.2 minutes vs. 109.8±11.6 minutes; P=0.001). In addition, there was no change in preoperative decision on type of flap harvested in all cases in 3D print group (0%), compared with 24.1% change in conventional CTA group. Conclusions Use of 3D print model improves accuracy of preoperative planning and reduces flap harvest time with similar postoperative complications in complex microsurgical reconstruction.

Reconstruction with Extracorporeally Radiated Autogenous Bone Graft After Wide Resection of Bone Tumors (골종양 절제후 방사선 조사한 자가골을 이용한 재건술)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Kim, Sug-Jun;Lee, Soo-Yong;Yang, Hyun-Seok
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.1
    • /
    • pp.32-38
    • /
    • 1997
  • PURPOSE : For the reconstruction of large bone defect after tumor resection, it is possible to reuse the bone involved by tumor with some treatment to it. Several bone-reusing methods have been reported such as autoclaving, low-heat treatment(pasteurization) and intraoperative radiotherapy. We have used extracorporeally radiated autogenous bone graft for reconstruction after tumor resection, and analyzed the periods for junctional union, functional results and complications to know the indications of this method. METHODS : From Dec. 1993 to Sept. 1995, nine patients had taken autogenous bone graft with extracorporeal irradiation. Eight cases were osteosarcoma and 1 giant cell tumor. The graft sites were 5 in femur, 3 proximal tibia and 1 femur and tibia. Stage 3 was 1 case(GCT), Stage IIB 3 and Stage IIIB 5. After wide resection, surrounding soft tissue and intramedullary and extramedullary portion of the tumor were removed. Radiation was done in 5000cGy to the resected bone. Ender nails and bone cement were inserted and filled into the medulla to prevent fracture. RESULTS : Average follow-up period was 12.3(4 to 21) months. Average junctional union period in simple X-ray was 6.5 months in 4 cases. Average functional score following Enneking's criteria was 19(12-27). Complications were as follows ; condylar fractures and femur neck fracture in 4 cases, subluxation of the knee joint 3 and infection 1. Although local recurrence was detected in 1 case, the site of recurrence was not in the radiated bone but surrounding soft tissue. At final follow-up, no recurrence was found in one case(GCT), CDF 2, AWD 2, DOD 3, and died of chemotherapy related sepsis 1. CONCLUSIONS : Extracorporeally radiated bone autograft is considered to be a method for reconstruction of the large bone defect made by tumor resection, especially in the reconstruction around the joint.

  • PDF

Comparison of the Outcomes between Axillary and Femoral Artery Cannulation for Acute Type A Aortic Dissection

  • Lee, Hong-Kyu;Kim, Gun-Jik;Cho, Joon-Yong;Lee, Jong-Tae;Park, Il;Lee, Young-Ok
    • Journal of Chest Surgery
    • /
    • v.45 no.2
    • /
    • pp.85-90
    • /
    • 2012
  • Background: At present, many surgeons prefer axillary artery cannulation because it facilitates antegrade cerebral perfusion and may diminish the risk of cerebral embolization. However, axillary artery cannulation has not been established as a routine procedure because there is controversy about its clinical advantage. Materials and Methods: We examined 111 patients diagnosed with acute type A aortic dissection between January 2000 and December 2009. The right axillary artery was cannulated in 58 patients (group A) and the femoral artery was cannulated in 53 (group F). The postoperative outcomes were retrospectively reviewed and compared between the two groups. Results: There were 46 male and 65 female patients with a mean age of $58.9{\pm}13.1$ years (range, 26 to 84 years). The extent of aortic replacement in both groups did not differ. There were 8 early deaths (7.2%) and 2 late deaths (1.8%). The mean follow-up duration was $46.0{\pm}32.6$ months (range, 1 month to 10 years). Transient neurologic dysfunction was observed in 11 patients (19.0%) in group A and 14 patients (26.4%) in group F. A total of 11 patients (9.9%) suffered from a permanent neurologic dysfunction. Early and delayed stroke were observed in 6 patients (10.3%) and 2 patients (3.4%), respectively, in group A as well as 2 patients (3.8%) and 1 patient (1.9%), respectively, in group F. There were no statistical differences in the cannulation-related complications between both groups (3 in group A vs. 0 in group F). Conclusion: There were no differences in postoperative neurologic outcomes and cannulation-related complications according to the cannulation sites. The cannulation site in an aortic dissection should be carefully chosen on a case-by-case basis. It is important to also pay attention to the possibility of intraoperative malperfusion syndrome occurring and the subsequent need to change the cannulation site.

The Role of Bone Cement Augmentation in the Treatment of Chronic Symptomatic Osteoporotic Compression Fracture

  • Kim, Hyeun-Sung;Kim, Sung-Hoon;Ju, Chang-Il;Kim, Seok-Won;Lee, Sung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.490-495
    • /
    • 2010
  • Objective : Bone cement augmentation procedures such as percutaneous vertebroplasty and balloon kyphoplasty have been shown to be effective treatment for acute or subacute osteoporotic vertebral compression fractures. The purpose of this study was to determine the efficacy of bone cement augmentation procedures for long standing osteoporotic vertebral compression fracture with late vertebral collapse and persistent back pain. Methods : Among 278 single level osteoporotic vertebral compression fractures that were treated by vertebral augmentation procedures at our institute, 18 consecutive patients were included in this study. Study inclusion was limited to initially, minimal compression fractures, but showing a poor prognosis due to late vertebral collapse, intravertebral vacuum clefts and continuous back pain despite conservative treatment for more than one year. The subjects included three men and 15 women. The mean age was 70.7 with a range from 64 to 85 years of age. After postural reduction for two days, bone cement augmentation procedures following intraoperative pressure reduction were performed. Imaging and clinical findings, including the level of the vertebra involved, vertebral height restoration, injected cement volume, local kyphosis, clinical outcome and complications were analyzed. Results : The mean follow-up period after bone cement augmentation procedures was 14.3 months (range 12-27 months). The mean injected cement volume was 4.1 mL (range 2.4-5.9 mL). The unipedicular approach was possible in 15 patients. The mean pain score (visual analogue scale) prior to surgery was 7.1, which decreased to 3.1 at 7 days after the procedure. The pain relief was maintained at the final follow up. The kyphotic angle improved significantly from $21.2{\pm}4.9^{\circ}$ before surgery to $10.4{\pm}3.8^{\circ}$ after surgery. The fraction of vertebral height increased from 30% to 60% after bone cement augmentation, and the restored vertebral height was maintained at the final follow up. There were no serious complications related to cement leakage. Conclusion : In the management of even long-standing osteoporotic vertebral compression fracture for over one year, bone cement augmentation procedures following postural reduction were considered safe and effective treatment in cases of non-healing evidence.

Comparison of $LigaSure^{TM}$ and Bipolar Vessel Sealing System for Laparoscopic Ovariectomy in Cats (복강경을 이용한 고양이의 난소 절제술에서 지혈기구인 $LigaSure^{TM}$와 양극 전기 응고 장치(bipolar)의 비교)

  • Jin, So-Young;Lee, Seung-Yong;Park, Se-Jin;Kim, Young-Ki;Seok, Seong-Hoon;Hwang, Jae-Min;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.477-482
    • /
    • 2014
  • The aim of this study was to investigate and compare technique, surgical time, and complications of laparoscopic ovariectomy using $LigaSure^{TM}$ and bipolar vessel sealing system in cats. Laparoscopic ovariectomy was performed under general anesthesia on 10 healthy female cats admitted for elective ovariectomy. Surgery was performed through three midline portals. Each ovary was randomly-assigned to removal by use of either $LigaSure^{TM}$ or bipolar vessel sealing system. Duration of predetermined surgery intervals and complications were compared. Bipolar OVE ($2:16{\pm}1:14$ minutes) took significantly longer surgical time compared to the $LigaSure^{TM}$ OVE ($1:24{\pm}0:59$ minutes, P = 0.021). The ovarian pedicle fat and obesity did not influence surgery duration. Intraoperative hemorrhage occurred with bipolar OVE in three cats, but had no significant influence on surgical time. The results suggest that both $LigaSure^{TM}$ and bipolar devices appear to be effective, but $LigaSure^{TM}$ can be used as a stand-alone device that decreases surgical time and complication compared with bipolar vessel sealing system.