Journal of The Korean Society of Integrative Medicine
/
v.4
no.2
/
pp.89-96
/
2016
Purpose : The purpose of this study was to evaluate inter-tester reliability and Intra-tester reliability about range of motion(ROM) measurement of hip joint with smartphone inclinometer. Method : Six observers performed goniometric and smartphone inclinometer measurements of various hip movements, including both active ROM for flexion, extension, external rotation, internal rotation. Measurements were performed in the right hip of fifty normal subjects. All measures were performed three times for evaluating reliability of observer. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient(ICC). Result : The results were as follows, inter-observer reliability ICC value showed .948-.974 in smartphone inclinometer. And showed .781-.827 in goniometer. Intra-observer reliability ICC value showed .653-.992 in smartphone inclinometer. And showed .613-.854 in goniometer. Conclusion : Smartphone inclinometer are portable and widely available tools that are mostly reliable and valid for assessing active hip range of motion, with potential use when a goniometer is not available.
International Journal of Internet, Broadcasting and Communication
/
v.10
no.3
/
pp.65-72
/
2018
The purpose of this study was to assess the intra-tester and inter-tester reliability and validity of elbow flexion range of motion using a smart phone used by the general public. Thirty-one general people participated in this study. The range of motion in active elbow flexion was measured with a goniometer and smart phone over two times by two observers. The intra-taster and inter-tester reliability were evaluated using the intraclass correlation coefficient(ICC). The validity was measured by Pearson's correlation coefficient. The intra-observer reliability was good in all measured items ICC>0.900. The inter-observer reliability was high with ICC>0.806. All correlation coefficients of android app and goniometer were greater than 0.868 and showed a significant positive correlation (p<0.01). The range of motion measurement with a smart phone showed acceptable reliability. Therefore, using a smartphone to measure the range of motion of the elbow joint could provide convenience and economic benefits.
Park, Sun-Wook;Kim, Myoung-Soo;Bae, Hyo-Sun;Cha, Yong-Ho
Journal of the Korean Society of Physical Medicine
/
v.10
no.2
/
pp.1-7
/
2015
PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.
Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.
Hwang, Eunjin;Antony, Chermaine Deepa;Choi, Jung-Ah;Kim, Minsu;Khil, Eun Kyoung;Choi, Il
Investigative Magnetic Resonance Imaging
/
v.25
no.2
/
pp.109-117
/
2021
Purpose: To investigate the reliability of CT and MRI for quantitative and qualitative analyses of lumbar paraspinal muscle fatty infiltration (PSFI) and correlation of PSFI with intervertebral disc pathology. Materials and Methods: Lumbar spine CT and MRI of 36 subjects were reviewed retrospectively. Two observers independently outlined lumbar paraspinal muscles at each mid-intervertebral disc level. Paraspinal muscles on CT and MRI were graded according to the Goutallier grading system (GGS). The area, mean value, and standard deviation (SD) of the Hounsfield unit (HU) were obtained. Intervertebral discs were assessed on axial image of T2WI at each level. Correlations between qualitative and quantitative data and intervertebral disc pathology, age, and sex were evaluated. Results: Inter- and intra-observer agreements for results of GGS on MRI were substantial (κ = 0.79) and moderate (κ = 0.59), respectively. Inter- and intra-observer agreements for results of GGS on CT were almost perfect (κ = 0.88) and substantial (κ = 0.66), respectively. Quantitative measurements of HU showed almost perfect inter- and intra-observer reliabilities (κ = 0.82 and κ = 0.99, respectively). There were statistically significant correlations between intervertebral disc pathology and PSFI at L1-2, L2-3, and L4-5 levels on MRI and at L1-2 and L3-4 levels on CT. Age showed significant correlation with results of GGS at all levels on CT and MRI. Conclusion: This study showed that GGS results and HU measurements could be useful for evaluating PSFI because they showed correlations with intervertebral disc pathology results at certain levels.
Huh, Jimi;Park, Jisuk;Kim, Kyung Won;Kim, Hyoung Jung;Lee, Jong Seok;Lee, Jong Hwa;Jeong, Yoong Ki;Shinagare, Atul B.;Ramaiya, Nikhil H.
Korean Journal of Radiology
/
v.19
no.6
/
pp.1066-1076
/
2018
Objective: The reliability of size measurements of liver metastases from neuroendocrine tumors (NETs) on contrast-enhanced computed tomography (CT) phases made by different readers may be hampered due to transient, variable rim enhancement in arterial phase (AP) or portal venous phase (PVP) images. We aimed to assess the reliability of tumor size measurements in pre- and post-contrast scans. Materials and Methods: The study coordinator selected target lesions according to Response Evaluation Criteria in Solid Tumors 1.1 guidelines in 44 consecutive patients with pathologically confirmed NET liver metastases. Two blinded readers measured the longest diameters of target lesions on pre-contrast, AP, and PVP images twice with a 4-week interval. Inter- and intra-observer agreements were evaluated using Bland-Altman plots and 95% limit of agreement (LOA) calculations. Results: Of the 79 target lesions (approximate mean size of 3 cm), 45 showed rim enhancement. Inter-observer agreement assessed based on LOA was highest in pre-contrast CT images (-6.1-5.7 mm), followed by PVP (-7.9-7.1 mm) and AP (-8.5-7.4 mm) images. Intra-observer agreement showed the same trend: -2.8-2.9 mm and -2.9-2.9 mm for readers 1 and 2, respectively, on pre-contrast CT, -2.8-2.9 mm and -3.0-3.2 mm, respectively, on PVP, and -3.2-4.2 mm and -3.4-3.2 mm, respectively, on AP images. Mean tumor diameters differed significantly among the phases in the following increasing order: pre-contrast CT, PVP, and AP images. Conclusion: There was better inter- and intra-observer agreement in size measurements of NET liver metastases on pre-contrast scans than on AP and PVP scans. Pre-contrast CT may be the optimal for measuring NET liver metastases if its accuracy is proven.
Purpose: The aim of this study was to evaluate the root canal morphology of mesial roots of mandibular first molars. Materials and Methods: Forty extracted mandibular first molars were used in this study. The morphological examination of root canals was conducted in accordance with the Vertucci classification using micro-computed tomography (micro-CT). Any aberrant root canal configurations not included in the Vertucci classification were recorded, and their frequency was established using descriptive statistics. Intra-observer reliability was assessed using the Wilcoxon signed-rank test, while inter-observer reliability was assessed using the Cohen kappa test. Significance was evaluated at the P<0.05 level. Results: The mesial roots of mandibular first molars had canal configurations of type I (15%), type II (7.5%), type III (25%), type IV (10%), type V (2.5%), type VI (7.5%), and type VII (7.5%). The images showed 10 (25%) additional configuration types that were not included in the Vertucci classification. These types were 1-3-2-3, 1-2-3-2-3, 2-3-1, 2-3, 1-2-3-1, 2-1-2-3, 3-2-1, 1-2-3-1, 2-3-2-3, and 1-2-1-2-1. The intra-observer differences were not statistically significant(P>0.05) and the kappa value for inter-observer agreement was found to be 0.957. Conclusion: Frequent variations were detected in mesial roots of mandibular first molars. Clinicians should take into consideration the complex structure of the root canal morphology before commencing root canal treatment procedures to prevent iatrogenic complications. Micro-CT was a highly suitable method to provide accurate 3-dimensional visualizations of root canal morphology.
Purpose: There are various methods proposed for the evaluation of the hindfoot alignment. However, due to structural calcaneus variances between patients, it is hard to assess this alignment definitively. Thus, this study proposes a new method for evaluating of the hindfoot alignment and its comparisons to the existing current methods. Materials and Methods: This study includes simple weight bearing hindfoot coronal view radiographs of 120 patients, taken between the time period of March 2008 to November 2009. Among the 120 patients, there was a 1:1 ratio of male to female with an average age of 40. The newly proposed method for evaluating this alignment is to draw a moment arm from the point where the sustentaculum tali meets the medial calcaneus border to the most prominent aspect of the lateral process of the calcaneal tuberosity. The angle produced via the intersection of this moment arm to the mid-longitudinal axis of the tibia is found and used to evaluate the hindfoot alignment. The inter and intra-observer reliability was evaluated using the coefficient of intraclass correlation. This study also investigates the comparisons between the newly proposed method to the traditionally used Saltzman et al hindfoot alignment evaluating technique. Results: The newly proposed method has higher inter and intra-observer reliability than the existing traditional Saltzman et al technique. Conclusion: This new method is recommended over the traditionally used Saltzman et al technique as it has a stronger confidence level and is appropriate for assessing hindfoot alignment in simple radiographs.
Purpose: To study the reliability of intra- and interobserver reliability in angular measurement of hallux valgus deformity by assessing hallux valgus angle (HVA) and the 1st to 2nd intermetatarsal angle (1-2 IMA) through using computerized system. Materials and Methods: 20 cases of moderate to severe hallux valgus patients were included in this study. With the standing anteroposterior view of foot, the HVA and 1-2 IMA were calculated by computerized measurement system of Infinity cooperation, called ${\pi}$-view, with its software tools. Using the statistical software program, SPSS (version 12th), we interpreted the results which were measured by two independent observers. Results: In the intraobserver measurement, the HVA of observer A showed reliability ($32.5^{\circ}{\pm}6.9$ and $33.1^{\circ}{\pm}6.8$)(p<0.05). 1-2 IMA in observer A was not regarded as reliable ($16.9^{\circ}{\pm}2.8$ and $17.1^{\circ}{\pm}2.8$)(p>0.05). In the results of observer B, HVAs were measured as $35.7^{\circ}{\pm}7.6$ and $36.2^{\circ}{\pm}7.7$, and were not reliable (p>0.05). 1-2 IMA in observer B was not reliable as well ($17.0^{\circ}{\pm}0.8$ and $20.8^{\circ}{\pm}1.5$)(p>0.05). In the interobservers' measurements, the first and the second results of HVA were $3.2^{\circ}{\pm}3.6$ and $3.1^{\circ}{\pm}3.1$, reliable within the 95% confidence interval (p<0.05). 1-2 IMAs were $0.1^{\circ}{\pm}1.9$ and $3.73^{\circ}{\pm}1.3$, which were not reliable (p>0.05). Conclusion: In the angular measurement of the hallux valgus by computerized system, the HVA and 1-2 IMA showed less error range in the interobserver's results, compared with the previous studies about the manual measurement. However, our results failed to show the statistical reliability of intra- and interobserver's measuring. Therefore, even the computerized angular measurements in the severity of hallux valgus require development of the measuring methods and software tools.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.