DOI QR코드

DOI QR Code

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah (Department of Neurosurgery, Yonsei University College of Medicine) ;
  • Ji, Gyu Yeul (Department of Neurosurgery, Yonsei University College of Medicine) ;
  • Oh, Chang Hyun (Spine and Joint Research Institute, Guro Cham Teun Teun Hospital) ;
  • Kim, Keung Nyun (Department of Neurosurgery, Yonsei University College of Medicine) ;
  • Yoon, Do Heum (Department of Neurosurgery, Yonsei University College of Medicine) ;
  • Shin, Hyunchul (Department of Neurosurgery, Kangbuk Samsung Hospital, Sungkyunkwan University College of Medicine)
  • Received : 2015.08.04
  • Accepted : 2016.02.26
  • Published : 2017.07.01

Abstract

Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.

Keywords

References

  1. Bakay L, Cares HL, Smith RJ : Ossification in the region of the posterior longitudinal ligament as a cause of cervical myelopathy. J Neurol Neurosurg Psychiatry 33 : 263-268, 1970 https://doi.org/10.1136/jnnp.33.2.263
  2. Chang H, Kong CG, Won HY, Kim JH, Park JB : Inter- and intra-observer variability of a cervical OPLL classification using reconstructed CT images. Clin Orthop Surg 2 : 8-12, 2010 https://doi.org/10.4055/cios.2010.2.1.8
  3. Chiba K, Kato Y, Tsuzuki N, Nagata K, Toyama Y, Iwasaki M, et al. : Computer-assisted measurement of the size of ossification in patients with ossification of the posterior longitudinal ligament in the cervical spine. J Orthop Sci 10 : 451-456, 2005 https://doi.org/10.1007/s00776-005-0925-5
  4. Chiba K, Ogawa Y, Ishii K, Takaishi H, Nakamura M, Maruiwa H, et al. : Long-term results of expansive open-door laminoplasty for cervical myelopathy--average 14-year follow-up study. Spine (Phila Pa 1976) 31 : 2998-3005, 2006 https://doi.org/10.1097/01.brs.0000250307.78987.6b
  5. Chiba K, Yamamoto I, Hirabayashi H, Iwasaki M, Goto H, Yonenobu K, et al. : Multicenter study investigating the postoperative progression of ossification of the posterior longitudinal ligament in the cervical spine : a new computer-assisted measurement. J Neurosurg Spine 3 : 17-23, 2005 https://doi.org/10.3171/spi.2005.3.1.0017
  6. Choi JH, Shin JJ, Kim TH, Shin HS, Hwang YS, Park SK : Does intramedullary signal intensity on MRI affect the surgical outcomes of patients with ossification of posterior longitudinal ligament? J Korean Neurosurg Soc 56 : 121-129, 2014 https://doi.org/10.3340/jkns.2014.56.2.121
  7. Fujimori T, Iwasaki M, Nagamoto Y, Ishii T, Sakaura H, Kashii M, et al. : Three-dimensional measurement of growth of ossification of the posterior longitudinal ligament. J Neurosurg Spine 16 : 289-295, 2012 https://doi.org/10.3171/2011.11.SPINE11502
  8. Han IH, Suh SH, Kuh SU, Chin DK, Kim KS : Types and prevalence of coexisting spine lesions on whole spine sagittal MR images in surgical degenerative spinal diseases. Yonsei Med J 51 : 414-420, 2010 https://doi.org/10.3349/ymj.2010.51.3.414
  9. Hori T, Kawaguchi Y, Kimura T : How does the ossification area of the posterior longitudinal ligament progress after cervical laminoplasty? Spine (Phila Pa 1976) 31 : 2807-2812, 2006 https://doi.org/10.1097/01.brs.0000245870.97231.65
  10. Iwasaki M, Okuda S, Miyauchi A, Sakaura H, Mukai Y, Yonenobu K, et al. : Surgical strategy for cervical myelopathy due to ossification of the posterior longitudinal ligament: Part 2: Advantages of anterior decompression and fusion over laminoplasty. Spine (Phila Pa 1976) 32 : 654-660, 2007 https://doi.org/10.1097/01.brs.0000257566.91177.cb
  11. Izumi T, Hirano T, Watanabe K, Sano A, Ito T, Endo N : Three-dimensional evaluation of volume change in ossification of the posterior longitudinal ligament of the cervical spine using computed tomography. Eur Spine J 22 : 2569-2574, 2013 https://doi.org/10.1007/s00586-013-2989-9
  12. Jayakumar PN, Kolluri VR, Vasudev MK, Srikanth SG : Ossification of the posterior longitudinal ligament of the cervical spine in Asian Indians--a multiracial comparison. Clin Neurol Neurosurg 98 : 142-148, 1996 https://doi.org/10.1016/0303-8467(96)00004-2
  13. Kawaguchi Y, Kanamori M, Ishihara H, Nakamura H, Sugimori K, Tsuji H, et al. : Progression of ossification of the posterior longitudinal ligament following en bloc cervical laminoplasty. J Bone Joint Surg Am 83-A : 1798-1802, 2001
  14. Lee T, Chacha PB, Khoo J : Ossification of posterior longitudinal ligament of the cervical spine in non-Japanese Asians. Surg Neurol 35 : 40-44, 1991 https://doi.org/10.1016/0090-3019(91)90200-S
  15. Matsunaga S, Kukita M, Hayashi K, Shinkura R, Koriyama C, Sakou T, et al. : Pathogenesis of myelopathy in patients with ossification of the posterior longitudinal ligament. J Neurosurg 96(2 Suppl) : 168-172, 2002
  16. Matsunaga S, Nakamura K, Seichi A, Yokoyama T, Toh S, Ichimura S, et al. : Radiographic predictors for the development of myelopathy in patients with ossification of the posterior longitudinal ligament: a multicenter cohort study. Spine (Phila Pa 1976) 33 : 2648-2650, 2008 https://doi.org/10.1097/BRS.0b013e31817f988c
  17. Morio Y, Nagashima H, Teshima R, Nawata K : Radiological pathogenesis of cervical myelopathy in 60 consecutive patients with cervical ossification of the posterior longitudinal ligament. Spinal Cord 37 : 853-857, 1999 https://doi.org/10.1038/sj.sc.3100940
  18. Nagata K, Sato K : Diagnostic imaging of cervical ossification of the posterior longitudinal ligament in Yonenobu K, Nakamura K, Toyama Y (eds) : OPLL : Ossification of the Posterior Longitudinal Ligament, ed 2. Tokyo : Springer, 2006, pp127-143
  19. Ogata N, Kawaguchi H : Ossitication of the posterior longitudinal ligament of spine (OPLL). Clin Calcium 14 : 42-48, 2004
  20. Seichi A : Updates on ossification of posterior longitudinal ligament. Image diagnosis of ossification of posterior longitudinal ligament and associated diseases. Clin Calcium 19 : 1426-1434, 2009
  21. Takatsu T, Ishida Y, Suzuki K, Inoue H : Radiological study of cervical ossification of the posterior longitudinal ligament. J Spinal Disord 12 : 271-273, 1999
  22. Tsuyama N : Ossification of the posterior longitudinal ligament of the spine. Clin Orthop Relat Res (184) : 71-84, 1984
  23. Yonenobu K, Tsuzuki N, Nagata K, Toyama Y, Kato Y, Iwasaki M : Computer-assisted measurement of ossified lesion in ossification of the posterior longitudinal ligament of the cervical spine. Bone 16 : 283-286, 2002
  24. Zhong ZM, Chen JT : Phenotypic characterization of ligamentum flavum cells from patients with ossification of ligamentum flavum. Yonsei Med J 50 : 375-379, 2009 https://doi.org/10.3349/ymj.2009.50.3.375

Cited by

  1. Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans vol.12, pp.4, 2017, https://doi.org/10.1111/os.12729
  2. Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans vol.12, pp.4, 2017, https://doi.org/10.1111/os.12729