• Title/Summary/Keyword: Intra-Class Correlation Coefficient

Search Result 70, Processing Time 0.022 seconds

The Study of Asymmetrical of the Serratus Anterior and Lower Trapezius Muscles in Chronic Stroke Patients (만성 뇌졸중 환자의 앞 톱니근과 하부 등세모근의 비대칭성 연구)

  • Jeong, Ju-Ri;Lee, Wan-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.81-90
    • /
    • 2015
  • PURPOSE: The purpose of this study was to compare the muscle architecture of serratus anterior and lower trapezius using rehabilitative ultrasound imaging (RUSI) in affected and unaffected side of chronic stroke patients. METHODS: The participants were thirty five patients with stroke hemiplegia in this study. RUSI was used to measure the muscle thickness of the serratus anterior and lower trapezius muscles. We compared the muscle thickness according to affected side and sex, determined the reliability of the measurement image. Independent t-test, intra-class correlation coefficient (ICC) and standard error of measurement (SEM) were used for statistical analysis. RESULTS: Significant difference in muscle thickness of serratus anterior was observed between affected and unaffected side (p<.001). Muscle thickness according to gender showed a significant difference in unaffected side of serratus anterior (p<.05). Compare asymmetry ratio of serratus anterior and lower trapezius muscle thickness showed a significant difference (p<.001). ICC for intra-reliability was .944~.962 in serratus anterior and .873~.925 in lower trapezius muscle thickness, respectively. SEM was .001~.004 in serratus anterior and .002~.008 in lower trapezius muscle. CONCLUSION: This study, using RUSI, showed significant difference in muscle thickness of serratus anterior in affected and unaffected side of stroke patients. RUSI is a practical tool for measuring soft-tissue thickness in the scapular region muscle of stroke.

Korean Translation, Cross Cultural Adaptation of Whiplash Disability Questionnaire: Pilot Study (Whiplash Disability Questionnaire의 한국어 번역 및 문화적 개작: 예비 연구)

  • Lee, Geon-Yeong;Jo, Hee-Geun;Kim, Shin-Ae;Park, Hye-Rin;Kim, Eun-Mi;Im, Hyeok-Bin;Jeong, Jun-Su
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.3
    • /
    • pp.87-96
    • /
    • 2018
  • Objectives The purpose of this study is to provide more whiplash injury-specific measurement tools for Korean patients by measuring the validity and reliability of Korean version of Whiplash Disability Questionnaire (WDQ). Methods Bilingual clinicians translated the original WDQ into Korean. After consensus conference between researchers, it was back-translated into English. The pre-final version was completed and administered to 71 hospitalized patients diagnosed with whiplash injury. Validity was evaluated by concurrent validity. Reliability was assessed using Cronbach's ${\alpha}$ and intraclass correlation coefficient. Results The Korean WDQ showed good reliability with high internal consistency and intra-class correlation coefficient (Cronbach's ${\alpha}=0.96$, intraclass correlation coefficient [ICC]=0.82). Concurrent validity demonstrated positive correlations between Neck Disability Index, 36-Item Short Form Health Survey and WDQ. Conclusions The Korean version of WDQ is a valid and reliable tool for use as a measurement of whiplash injury in Korean patients, and it will be a very useful evaluation tool for both clinicians and researchers.

Reliability and validity of rehabilitative ultrasound images obtained using a hands-free fixed probe in measuring the muscle structures of the tibialis anterior and the gastrocnemius

  • Choi, Mun-Sang;Shin, Jang-Hoon;Park, Hye-Kang;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.194-201
    • /
    • 2019
  • Objective: This study aimed to investigate the reliability and validity of muscle thickness (MT) and pennation angle (PA) measurements of the ankle muscle, including the tibialis anterior (TA) and the medial gastrocnemius (MGCM), using a hands-free fixed probe and to compare it with the conventional linear probe. Design: Observational inter-rater reliability study. Methods: Thirty-three healthy subjects (20 male, 13 female) were included. In all subjects, ultrasound images were acquired from the TA and MGCM using a hands-free fixed probe and a conventional linear probe in random sequence by two examiners at two time-points within a 7-day interval. MT and PA were calculated on the taken images. Intra-class correlation coefficients (ICC), 95% confidence intervals, standard error of measurement and the Pearson's correlation coefficient were used to estimate reliability and validity. And also, Bland-Altman plots were generated for a visual representation of MT and PA at the TA and MGCM. Results: The ICC for all intra-rater reliability was 0.943 to 0.995 and that for all inter-rater reliability was 0.928 to 0.993, indicating excellent reliability. A significantly high correlation was observed between MT and PA at the TA and MGCM with use of the hands-free fixed probe and the conventional linear probe (r>0.938; p<0.001). Conclusions: The hands-free fixed probe provided excellent images for measurement of the MT and PA of the TA and MGCM and is a useful device for making clinical measurements of muscle structure without grasping of the probe.

Association between Taql polymorphism of vitamin D receptor gene and vertical growth of the mandible: A cross-sectional study

  • Baris Can Telatar;Gul Yildiz Telatar;Faruk Saydam
    • The korean journal of orthodontics
    • /
    • v.53 no.5
    • /
    • pp.336-342
    • /
    • 2023
  • Objective: To determine whether the gonial angle on digital panoramic radiographs is associated with vitamin D receptor (VDR) Taql polymorphism. Methods: Genomic DNA samples were collected from the buccal mucosa of patients aged 26-43 years. TaqMan assay for single nucleotide polymorphism genotyping was used to detect the genotype of Taql polymorphism. The gonial angle was measured bilaterally on panoramic radiography. The normal gonial angle was fixed as 121.8°, and it represented the cutoff value for the high gonial angle (HGA) and low gonial angle (LGA) groups. Various genetic models were analyzed, namely dominant (homozygous [AA] vs. heterozygous [AG] + polymorphic [GG]), recessive (AA + AG vs. GG), and additive (AA + GG vs. AG), using the chi-squared test. Results: The reliability of the gonial angle measurement was analyzed using a random sample (26%) of the tests, with the intra-examiner correlation showing an intra-class correlation coefficient of 0.99. The frequencies of the AA, AG, and GG genotypes of rs731236 polymorphism were 40.5%, 41.9%, and 17.6% in the HGA group and 21.8%, 51.0%, and 27.2% in the LGA group, respectively (P = 0.042). A statistically significant difference was observed in the allele frequencies between the two groups (P = 0.011). Moreover, a significant correlation was observed in the dominant genetic model. Conclusions: Taql polymorphism in the VDR gene plays a critical role in the vertical growth of the mandible and decreased gonial angle.

Reliability of External Ear Measurements Obtained by Direct, Photocopier Scanning and Photo Anthropometry

  • Liu, Bor-Shong;Tseng, Hsien-Yu;Chia, Tung-Chung
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.1
    • /
    • pp.20-27
    • /
    • 2010
  • The purpose of this study was to compare the consistency of external ear measurements obtained by electronic digital caliper, photocopier scanning and digital photographic methods. Photogrammetric measurements were made after image editing software was used to optimize the brightness, contrast, size and image clarity. The CorelDRAW dimension tool was used to create a dimension line that measured the vertical and horizontal length between any two landmarks. Results of repeated measures analysis of variance revealed no significant differences in length and width of the pinna between the three methods. The reliability of the three measurement techniques showed a high degree of consistency. Further study and efforts could be extended to measurement hands, foots and facial dimensions by present techniques.

Development and Validation of a Korean Nursing Work Environment Scale for Critical Care Nurses (한국형 중환자실 간호근무환경 측정도구 개발 및 평가)

  • Lee, Hyo Jin;Moon, Ji Hyun;Kim, Se Ra;Shim, Mi Young;Kim, Jung Yeon;Lee, Mi Aie
    • Journal of Korean Clinical Nursing Research
    • /
    • v.27 no.3
    • /
    • pp.279-293
    • /
    • 2021
  • Purpose: The purpose of this study was to develop a Korean nursing work environment scale for critical care nurses (KNWES-CCN) and verify its validity and reliability. Methods: A total of 46 preliminary items were selected using content validity analysis of experts on 64 candidate items derived through literature reviews and in-depth interviews with critical care nurses. 535 critical care nurses from 21 hospitals responded to the preliminary questionnaire from February to March 2021. The collected data were analysed using construct, convergent and discriminant validities, and internal consistency and test-retest reliability. Results: The 23 items in 4 factors accounted for 55.6% of the total variance were identified through item analysis and exploratory factor analysis (EFA). EFA was performed with maximum likelihood method including direct oblimin method. In the confirmatory factor analysis, KNWES-CCN consisted of 21 items in 4 factors by deleting the items that were not meet the condition that the factor loading over .50 or the squared multiple correlation over .30. This model was considered to be suitable because it satisfied the fit index and acceptable criteria of the model [𝒳2=440.47 (p<.001), CMIN/DF=2.41, GFI=.86, SRMR=.06, RMSEA=.07, TLI=.90, CFI=.91]. The item total correlation values ranged form .32 to .73 and its internal consistency was Cronbach's α=.92. The reliability of the test-retest correlation coefficient was .72 and the intra-class correlation coefficient was .83. Conclusion: The KNWES-CCN showed good validity and reliability. Therefore, it is expected that the use of this scale would measure and improve nursing work environment for critical care nurses in Korea.

Evaluating the Reliability of Short-Form Berg Balance Scales and Short-Form Postural Assessment Scales in Chronic Stroke Survivors

  • Seung-Heon An;Dae-Sung Park
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.143-151
    • /
    • 2024
  • Objective: This study aims to assess the test-retest reproducibility of the Short Form Berg Balance Scale (SF-BBS) and the Short Form Postural Assessment Scale for Stroke (SF-PASS) among chronic stroke survivors, focusing on their reliability for consistent measurements over time. Design: A cross-sectional study design Methods: Thirty chronic stroke survivors participated in this study, undergoing evaluations with SF-BBS and SF-PASS scales at two different points, separated by a seven-day interval. The analysis focused on test-retest reliability, employing statistical measures such as the Intra-Class Coefficient (ICC2,1), Standard Error of Measurement (SEM), Minimal Detectable Change (MDC), and MDC%, the Bland-Altman plot to assess the limits of agreement and the extent of random measurement error. Results: The study found notable test-retest reproducibility for both SF-BBS and SF-PASS, with ICC values demonstrating strong reliability (0.932 to 0.941, with a confidence interval of 0.889 to 0.973). SEM values for SF-BBS and SF-PASS were reported as 1.34 and 0.61, respectively, indicating low measurement error. MDC values of 3.71 for SF-BBS and 1.69 for SF-PASS suggest that the scales have an acceptable level of sensitivity to change, with reliability metrics falling below 20% of the maximum possible score. Conclusions: The findings suggest that both SF-BBS and SF-PASS exhibit high intra-class correlation coefficients, indicating strong test-retest reliability. The SEM and MDC values further support the scales' reproducibility and reliability as tools for evaluating mobility and dynamic balance in chronic stroke survivors. Therefore, these scales are recommended for clinical use in this population, providing reliable measures for assessing progress in rehabilitation.

Development of the Meaning in Life Scale for Older Adults (노인의 삶의 의미 측정 도구 개발)

  • Lee, Si Eun;Hong, Gwi-Ryung Son
    • Journal of Korean Academy of Nursing
    • /
    • v.47 no.1
    • /
    • pp.86-97
    • /
    • 2017
  • Purpose: The purpose of this study was to develop and test the psychometric properties of the newly developed instrument, Meaning in Life, for elderly Korean people. Methods: Ten older adults participated in the qualitative research used to develop the initial items. Participants for the psychometric testing were 371 community-dwelling older adults. Validity and reliability analyses included content, construct, and criterion-related validities, internal consistency, and test-retest reliability. Results: The Meaning in Life Scale consisted of 12 items with three distinct factors; value of life, source of life, and will to live, which explained 86.7% of the total variance. A three-factor structure was validated by confirmatory factor analysis. Criterion-related validity was supported by comparison with the Purpose in Life Test (r=.74). Reliabilities were secured with test-retest reliability of Intra-class Correlation Coefficient (ICC) .85 and the Cronbach's alpha coefficient .90. Conclusion: The results of this study indicate that this instrument is useful to measure meaning in life in Korean elders.

Reliability and Validity of Patient Oriented Eczema Measure (POEM) Korean Version

  • Kim, Yoon-Ha;Han, Jong-Min;Jung, In-Chul;Kang, Weechang;Park, Yang-Chun
    • The Journal of Korean Medicine
    • /
    • v.37 no.4
    • /
    • pp.22-29
    • /
    • 2016
  • Objectives: We developed a Korean translation of this questionnaire by sequential forward-and-backward translation. The purpose of this study is to validate the Korean version of the POEM, the "POEM-K" by Korean patients with atopic dermatitis (AD). Methods: A single-center prospective study was conducted with 50 participants diagnosed with AD. The POEM was translated to Korean version by an expert panel. Scoring Atopic Dermatitis (SCORAD) and Short Form 36 Health Survey (SF-36) were used as external comparators. Results: Twenty men and thirty women between the ages of 18 and 63 participated in the study. The test-retest reliability of the total POEM-K was estimated using the intra-class correlation coefficient (ICC) that showed a strong agreement (ICC = 0.72). By using Pearson correlation coefficients, we compared the POEM-K to SCORAD and yielded a concurrent validity that showed a significant result. The responsiveness of the POEM-K was represented by the effect size (ES) of 1.41 and statistically significant (p = 0.004). Conclusions: The Korean version of the POEM is a reliable, valid, and responsive disease-specific questionnaire for assessing the symptoms and quality of life of Korean patients with AD.

Evaluation of the Developmental Age of Permanent Teeth by the Nolla Method (Nolla 방법을 이용한 영구치의 발육 연령 평가)

  • Shin, Minkyung;Song, Jeseon;Lee, Jaeho;Choi, Byungjai;Kim, Seongoh;Lee, Hyoseol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • The developmental age of permanent teeth was evaluated in children and adolescents according to age and gender using the Nolla Method. A retrospective study was performed on panoramic radiographs of 1,200 subjects aged 4-15 years, including 50 children for each age/gender group. Three well-trained examiners estimated the developmental stage of upper and lower permanent teeth using the Nolla Method. The inter-examiner reliability was excellent (intra-class correlation coefficient value = 0.973). The mean developmental age was calculated. In boys, Nolla stage 6, indicated by crown completion, was seen in the central incisor, lateral incisor, canine, first premolar, second premolar, first molar, and second molar at 5.4, 6.4, 6.7, 7.5, 7.8, 4.6, and 8.1 years, respectively, in the maxilla and at 4.8, 5.1, 6.0, 6.5, 7.2, 4.5, and 8.0 years, respectively, in the mandible. In girls, Nolla stage 6 was seen at 5.3, 6.0, 6.3, 7.3, 7.7, 4.8, and 8.1 years, respectively, in the maxilla and at 4.8, 5.1, 5.9, 6.5, 7.2, 5.0, and 7.9 years, respectively, in the mandible. In this study, the developmental age of permanent teeth was evaluated in Korean children and adolescents who visited Yonsei University Dental Hospital. This study may be helpful in diagnosis and treatment planning in the clinic.