• Title/Summary/Keyword: Internal voltage

Search Result 659, Processing Time 0.03 seconds

A Study on the partial Discharge Characteristics according to the Distribution pattern of voids within LDPE (보이드 분포 형태에 따른 LDPE의 부분 방전 특성 연구)

  • Shin, Doo-Seong;Jeon, Seung-Ik;Lee, Jun-Ho;Yun, Do-Hong;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1081-1084
    • /
    • 1995
  • Internal voids located within an insulation will arise partial discharge that causes local breakdown and even the entire insulation breakdown. For HV apparatuses, it is usual case that several voids are formed within non-uniform electric field condition rather than single void within uniform field, which can be solved analitically. The purpose of this work is to study partial discharge and breakdown characteristics of an insulation according to the distribution pattern of two disc-type voids that are located within non-uniform field. The results from numerical field analysis and experiments show that the electric field within the voids decreases as they are arranged more serially, which accordingly results in the increase of partial discharge inception field(PDIF) much higher than that of single void model. With parallel arranged voids, PDIF is almost the same as that of single void model. On the other hand, AC breakdown strength decreases as voids are arranged more serially, which is a natural result considering the reduction of effective insulation thickness. For parallel voids, this effect cannot he noticed where as they show different pattern compared with single void and serial void models in $\Phi$-Q-N analysis. Considering these results may leads us to the conclusion that, in the evaluation of insulating products through PD test, it is not sufficient to determine only PDIV or existence of PD at predetermined voltage level. We could evaluate more accurately by considering all the available data such as PDIV, PD magnitude, PD occurring phase, number of PD pulses, and etc.

  • PDF

An internal multi-band antenna for mobile handset using two slots (두 개의 슬롯을 이용한 단말기용 다중대역 내장형 안테나)

  • Ahn, Sang-Kwon;Choi, Sunho;Kwak, Kyung-Sup
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.1
    • /
    • pp.61-66
    • /
    • 2014
  • This paper describes the design, fabrication, and measurement of a compact hexa-band coupling antenna for 4G mobile handset using a small element with two slots. In order to obtain sufficient bandwidth (LTE700, GSM850, GSM900, GSM1800, GSM1900, UMTS) with a Voltage Standing Wave Ratio $(VSWR){\leq}3:1$, two slots are inserted in the small element, and coupling patch is used. The measured result of the fabricated antenna provides 410MHz bandwidth form 0.688 to 1.098GHz and 643 MHz bandwidth form 1.607 to 2.250GHz (${\leq}VSWR 3:1$) with the gain ranging from -0.52 to 4.68 dBi. Also, a good radiation pattern is achieved within the hexa-band (0.698-0.960GHz and 1.710-2.170GHz) range.

Evaluation of EM Susceptibility of an PLL on Power Domain Networks of Various Printed Circuit Boards (다양한 PCB의 전원 분배 망에서의 PLL의 전자기 내성 검증)

  • Hwang, Won-Jun;Wee, Jae-Kyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.74-82
    • /
    • 2015
  • As the complexity of an electronic device and the reduction of its operating voltage is progressing, susceptibility test of the chip and module for internal or external noises is essential. Although the immunity compliance of the chip was served with IEC 62132-4 Direct Power Injection method as an industry standard, in fact, EM immunity of the chip is influenced by their Power Domain Network (PDN). This paper evaluates the EM noise tolerance of a PLL and compares their noise transfer characteristics to the PLL on various PCB boards. To make differences of the PDNs of PCBs, various PCBs with or without LDO and with several types of capacitors are tested. For evaluation of discrepancies between EM characteristics of an IC only and the IC on real boards, the analysis of the noise transfer characteristics according to the PDNs shows that it gives important information for the design having robust EM characteristics. DPI measurement results show that greatly improved immunity of the PLL in the low-frequency region according to using the LDO and a frequency change of the PLL according to the DPI could also check with TEM cell measurement spectrum.

Structural health monitoring of seismically vulnerable RC frames under lateral cyclic loading

  • Chalioris, Constantin E.;Voutetaki, Maristella E.;Liolios, Angelos A.
    • Earthquakes and Structures
    • /
    • v.19 no.1
    • /
    • pp.29-44
    • /
    • 2020
  • The effectiveness and the sensitivity of a Wireless impedance/Admittance Monitoring System (WiAMS) for the prompt damage diagnosis of two single-storey single-span Reinforced Concrete (RC) frames under cyclic loading is experimentally investigated. The geometrical and the reinforcement characteristics of the RC structural members of the frames represent typical old RC frame structure without consideration of seismic design criteria. The columns of the frames are vulnerable to shear failure under lateral load due to their low height-to-depth ratio and insufficient transverse reinforcement. The proposed Structural Health Monitoring (SHM) system comprises of specially manufactured autonomous portable devices that acquire the in-situ voltage frequency responses of a network of twenty piezoelectric transducers mounted to the RC frames. Measurements of external and internal small-sized piezoelectric patches are utilized for damage localization and assessment at various and increased damage levels as the magnitude of the imposed lateral cycle deformations increases. A bare RC frame and a strengthened one using a pair of steel crossed tension-ties (X-bracing) have been tested in order to check the sensitivity of the developed WiAMS in different structural conditions since crack propagation, damage locations and failure mode of the examined frames vary. Indeed, the imposed loading caused brittle shear failure to the column of the bare frame and the formation of plastic hinges at the beam ends of the X-braced frame. Test results highlighted the ability of the proposed SHM to identify incipient damages due to concrete cracking and steel yielding since promising early indication of the forthcoming critical failures before any visible sign has been obtained.

Performance characteristics of AGM lead acid battery with the content of positive plate incorporating nano-size additive material (나노 사이즈 입자가 포함된 양극 활물질 함량에 따른 차량용 AGM 연축전지 성능 특성)

  • Lim, Tae Seop;Kim, Sung Jun;Kim, Sang Dong;Yang, Seung Cheol;Jung, Yeon Gil
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.4
    • /
    • pp.123-130
    • /
    • 2020
  • Nano seed incorporated in micro-sized 4BS (Tetrabasic lead Sulfate) seed was applied to the positive electrode active material and compared with Nano 4BS seed (NS). The dispersion of NS decreased due to the aggregation phenomenon, while the nano seed incorporated in micro-sized 4BS seed (INS) could confirm excellent dispersion. As the content of INS increased, the particle size of the active material became small and constant, which was confirmed through SEM and particle size analysis. The specific surface area for the reaction was increased and the high-rate discharge and lifetime characteristics were improved. In order to confirm the variation in particle size distribution in the plate manufacturing process, internal resistance and voltage were measured for 200 AGM lead-acid batteries, and it was confirmed that batteries quality variation decreased.

Application and verification analysis of the thermoelectric generation system for a coastal fishing vessel (열전발전 장치의 연안어선 활용에 관한 연구)

  • LEE, Donggil;YANG, Yongsu;KIM, Pyungkwan;KIM, Seonghun;KIM, Hyunyoung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.2
    • /
    • pp.196-203
    • /
    • 2017
  • The renewable energy sources can be thought of one of the major measures to reduce greenhouse gas emissions in the industries. However, the utilization technology for those sources is approaching in the different matters. One of them, thermoelectric generation might be applicable to fishing industry. A various of internal combustion engines are used in a wide range of fisheries. After the ignition process, the heat passed out from the exhaust outlet. Recycling the heat could be not only an energy source but also reduction of green gas emission. Therefore, this study was designed to verify the feasibility of generation from wasted exhaust gas and analyze the performance. The designed experiment devices were connected with a data logger and an electric loader to quantify the currency and voltage. The devices were installed in a coastal fishing vessel for a gillnet fishery. During the whole fishing trips, the amount of generation was measured by engine rpm and the fishing operation procedures including vessel operations. At the maximum 1,500 rpm in the practical range, the generation amount was 113.6 W. The amount difference in relation to connection method was within 5 W: serial connection was 111.4 W and parallel connection was 115.8 W.

The Properties of Na-Ca Exchange Current in Single Atrial Cells of ,The Rabbit (토끼 단일 심방근 세포에서 Na-Ca 교환전류의 특성에 관한 연구)

  • Youm, Wook;Ho, Won-Kyung;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.548-561
    • /
    • 1989
  • In single atrial cells isolated from the rabbit the properties of inward current of Na-Ca exchange were investigated using the whole cell voltage clamp technique. The current was recorded during repolarization following brief 2 ms depolarizing pulse to +40 mV from a holding potential of * 70 mV. Followings are the results obtained: 1. When stimulated every 30 seconds, the inward currents were activated and reached peak values 6-12 ms after the beginning of depolarizing pulse. The mean current amplitude was 342 pA/cell. 2. The current decayed spontaneously from the peak activation and the time course of the relaxation showed two different phases fast and slow phase. The time constants were 10-18 ms and 60-140 ms, respectively. 3. The recovery of inward current was tested by paired pulse of various intervals. The peak current recovered exponentially with time constant of 140 ms and 1 p M isoprenaline accelerated the recovery process. 4. Relaxation time course was also affected by pulse interval and time constant of the fast phase was reduced almost linearly according to the decrease of pulse interval between 30 sec and 1 sec. 5. The peak activation was increased in magnitude by long prepulse stimulation, 5 p M Bay K, 1 p M isoprenaline or internal and external application of c-AMP. 6. The relaxation time constant of the fast phase was prolonged by 5 p M Bay K or c-AMP, and shortened by isoprenaline. However the time course of the slow relaxation phase was not so much changed. From the above results, it could be concluded that increase of the calcium current by Bay K or c-AMP results in the potentiation and prolongation of intracellular calcium transient, and the facilitation of Ca uptake by SR might be a mechanism of shortening the time constant of current relaxation by short interval stimulation or isoprenaline.

  • PDF

Effect of Space Charge Density and High Voltage Breakdown of Surface Modified Alumina Reinforced Epoxy Composites

  • Chakraborty, Himel;Sinha, Arijit;Chabri, Sumit;Bhowmik, Nandagopal
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.3
    • /
    • pp.121-124
    • /
    • 2013
  • The incorporation of 90 nm alumina particles into an epoxy matrix to form a composite microstructure is described in present study. It is shown that the use of ultrafine particles results in a substantial change in the behavior of the composite, which can be traced to the mitigation of internal charges when a comparison is made with conventional $Al_2O_3$ fillers. A variety of diagnostic techniques have been used to augment pulsed electro-acoustic space charge measurement to provide a basis for understanding the underlying physics of the phenomenon. It would appear that, when the size of the inclusions becomes small enough, they act cooperatively with the host structure and cease to exhibit interfacial properties. It is postulated that the $Al_2O_3$ particles are surrounded by high charge concentrations. Since $Al_2O_3$ particles have very high specific areas, these regions allow limited charge percolation through $Al_2O_3$ filled dielectrics. The practical consequences of this have also been explored in terms of the electric strength exhibited. It would appear that there was a window in which real advantages accumulated from the nano-formulated material. An optimum filler loading of about 0.5 wt.% was indicated.

A Study on Performance of Solid Oxide Fuel Cell Stack for Ship Applications (선박 전원용 고체산화물형 연료전지(SOFC) 스택 성능에 관한 연구)

  • Park, Sang-Kyun;Kim, Young-Jin;Roh, Gill-Tae;Kim, Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.406-413
    • /
    • 2011
  • Recently the fuel cell has been spotlighted as a technology to reduce greenhouse gases emission from a ship. In this research, internal reforming 500kW solid oxide fuel cell stacks fueled by methane for a ship were developed. Characteristics of power and efficiency depending on the number of cells in the stack, hydrogen conversion ratio, and active area of the cell are evaluated. Also the effects of air and methane supplying conditions on performance are analyzed. As a result, as the number of cells, hydrogen conversion ratio, active area of the cell, or supplied air flow rate increase, the stack power and efficiency increase. When the methane flow rate increases, the power increases. However the efficiency decreases. In addition, the case at the current of 976.4 A, voltage of 529.1 V, with corresponding power of 516.6 kW shows that the efficiency of fuel cell stack is 42.91%.

Sensorless Precision Speed Control of PM BLDC Motor (PM BLDC 모터의 센서리스 정밀 속도 제어)

  • Won, Chung-Yuen;Kim, Yuen-Chung;Yoon, Yong-Ho;Kim, Hack-Seong;Lee, Byuong-Kuk;Chun, Jang-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.48-56
    • /
    • 2006
  • This paper studies particularly applicable method for sensorless PM BLDC motor drive system. The waveform of the motor internal voltages(or back emf) contains a fundamental and higher order frequency harmonics. Therefore the third harmonic component is extracted from the stator phase voltage. The resulting third harmonic signal keeps a constant phase relationship with the rotor flux for any motor speed and load condition. Also because of low resolution of estimated signal obtained by the proposed sensorless algorithm, to improve the wide range of speed response characteristic more exactly, we propose the rotor position signal synthesizer using PLL circuit based on estimated signals. Some experimental results are provided to demonstrate the validity of the proposed control method.