Abstract
Recently the fuel cell has been spotlighted as a technology to reduce greenhouse gases emission from a ship. In this research, internal reforming 500kW solid oxide fuel cell stacks fueled by methane for a ship were developed. Characteristics of power and efficiency depending on the number of cells in the stack, hydrogen conversion ratio, and active area of the cell are evaluated. Also the effects of air and methane supplying conditions on performance are analyzed. As a result, as the number of cells, hydrogen conversion ratio, active area of the cell, or supplied air flow rate increase, the stack power and efficiency increase. When the methane flow rate increases, the power increases. However the efficiency decreases. In addition, the case at the current of 976.4 A, voltage of 529.1 V, with corresponding power of 516.6 kW shows that the efficiency of fuel cell stack is 42.91%.
최근 선박에서 배출되는 온실가스를 저감하기 위한 기술로 연료전지가 주목 받고 있다. 본 연구에서는 메탄을 연료로 사용한 내부개질형 500kW급 고체산화물 연료전지의 선박 적용을 가정하여 연료전지 스택을 모델링하여 스택을 구성하는 셀의 수, 수소 변환율, 셀의 반응면적에 따른 출력 및 효율에 관한 특성을 평가하고, 공기와 메탄의 공급조건이 연료전지 스택의 성능에 미치는 영향 등에 관하여 검토하였다. 그 결과 셀의 수, 수소 변환율, 셀의 반응면적 및 공급 공기 유량이 증가할수록 스택의 출력 및 효율이 증가하였고, 메탄 공급 유량이 증가하면 출력은 증가하지만 효율은 감소하였다. 또한 Case 3의 경우에 전류가 976.4 A, 전압이 529.1 V에서 출력이 516.6 kW이고 이때의 연료전지 스택의 효율은 42.91%를 얻을 수있었다.